HX3 Flash for OEMs
Information given here is intended for OEM use only.
Due to some demand I changed the HX3 Flash updater app behaviour.
Former versions of HX3 Flash looked what firmware was installed on the HX3 board and tried to determine what might be adequate to install. That often lead to unwanted results if parameters in new firmware changed significantly. Or I had a lot of work implementing minor parameter changes for various OEM *.hex files.
The new HX3 Flash is customizable by OEMs like you, so it might be completely adapted to your needs. You might prepare a package for your customers like the Flash_*.ZIPs on
https://github.com/keyboardpartner/HX3/tree/master/LATEST
containing only the necessary files for a specific instrument. The behaviour of HX3 Flash is controlled by an INI file named hx3_flash_config.ini which is human-readable and may be edited by a simple text editor. Content of INI looks like this example:
/ Configuration file for HX3 Standard Organ / Disable lines with comment char '/' at start / Extend to other parameters at own discretion [Files]= / The firmware_name is just shown in HX3 flash window. firmware_name=HX3 StandardOrgan / Files to use. Must be present in same folder. avr_filename=HX3mk3_std.hex fpga_filename=fpga_20122015.bit taper1_filename=taper_levels1.dat taper2_filename=taper_levels2.dat taper3_filename=taper_levels3.dat taper4_filename=taper_levels4.dat [ButtonEnables]= / Disable buttons that should not be used restore_organ=false restore_presets=true restore_midi=true [Parameters]= / parameters that must be restored to old value end with '=?' / Boolean on/off values are 255 or 0 / Disable lines with comment char '/' at start / MIDI Channel: 433=? / Split default mode: /436=? / Jack config A: 438=? / Jack config B: 439=? / ScanCore: 477=? / Analog input Enable: 478=? / Button mask PL7: 479=? / Button mask PL11: 480=? / Preset number to select second drawbar set: 483=? / No splitted Preset16 panel: 484=? / Save tabs to presets: 485=? / parameters to set do have a value / Boolean values are 0 or 255 / Disable lines with comment char '/' at start / Jack config A: /438=1 / Jack config B: /439=18 / ScanCore: 477=0 / Button mask PL7: 479=255 / Button mask PL11: 480=240 / Preset number to select second drawbar set: 483=1 / No splitted Preset16 panel: /484=0 / Save tabs to presets: /485=1 [End]
As you see, you can decide which buttons are enabled and which parameters have to be tweaked after firmware was installed. User Name and Licences are always retained.
Therefore, you may adjust parameters to your taste or to requirements of your instrument - without urging me to re-compile just for some parameter issues. All parameter numbers given in HX3 Remote pages are valid, so you may even change rotary params or MIDI CCs.