HX3 Board Installation: Unterschied zwischen den Versionen

Aus KeyboardPartner Wiki
Zur Navigation springenZur Suche springen
 
(235 dazwischenliegende Versionen desselben Benutzers werden nicht angezeigt)
Zeile 1: Zeile 1:
'''"Hammond on a Xilinx FPGA," HX3 single-board sound engine for connecting any keyboard, for installation into existing organs or MIDI control  
'''HX3 single-board sound engine for connecting any keyboard, for installation into existing organs or MIDI control'''
'''
[[Datei:HOAX.jpg|400px|thumb|right|'''HX3 board ready for installation''']]


==Features==
[[Datei:HOAX.jpg|400px|thumb|right|'''HX3 mk2 board ready for installation''']]
* Compact organ emulator module on single PCB, 200 x 100 mm, for OEM installation
* Authentic reproduction of generator, tapering, key contacts, percussion and vibrato by FPGA (Field Programmable Gate Array)
* Extremely low latency of 50 microseconds Key-to-Audio (not >20 ms as with other MIDI expanders and software emulation)
* Natural key click by "rattling" contacts
* Accurate Leslie simulation with separate outputs
* MIDI IN accepts 5 different MIDI CC sets
* Drawbar connection by 9 to 24 analog control voltages
* Connection for switches (active low) or digital switch control voltages (Percussion ON, Soft / Normal, 2nd/3rd, vibrato, vibrato ON upper/lower, chorus / vibrato)
* MIDI-in/out (accepts different MIDI CC sets)
* Connection of any type of keyboards (key contact to ground or matrix) with additional scan board (optional)


==Jack Connections==
==Installation==
The HX3 module has two "stereo" type 1/4" '''audio output jacks''', one DC input jack and two accessory jacks. Signals are also availabe on four 3-pin header solder pads located under jacks on PCD solder side.


* '''MAIN/BASS:''' Separate output for main organ manuals (plug tip) and pedal (plug ring) on jack if 3-pin jumper JP6 set to 2-CHANNEL. Use Y-cable or stereo cable to obtain all channels. Outut is mono (mix of manuals and bass) if JP6 set to MONO (only plug tip connected). Output level is approx. 150 mV at full swell.
===Requirements===
* '''LESL/AMP:''' Leslie simulation (mono, plug tip) and leslie amp simulation (122 amp without speakers, but with overdrive capabilities, plug ring). Output level is 300 mV (full "Leslie Volume"). The separate AMP output (plug ring) may be used with transistor leslies to obtain the nice tube overdrive effect provided by HX3. On higher "Leslie Volume" levels, you will notice the tube overdrive/distortion of simulated 6550 output stage.
* '''SWELL:''' Expression pedal input is compatible with Yamaha FC-7 and similar expression pedals (direct connection preferred for speed/accuracy, but may also be remoted by MIDI CC 11).
* '''FOOTSW:''' Single or double footswich controls simulated '''Leslie speed''' as well as Leslie I/F control bits (pin 1 to 4 on HX3 PL12): SLOW/FAST on plug tip, RUN/STOP on plug ring. Please use latching foot switches; momentary (button type) switches are not supported. If single footswitch used, Leslie is always on RUN (no plug ring, input grouded by plug sleeve).
* '''DC IN:''' Use stabilized DC wall wart 9 to 12V with at least 800mA current output, inner/outer plug diameter 2.1/5.5 mm on DC input jack. Regard jumper setting of JP12 (see below - must be removed for 9 to 12V voltages). Alternatively, use stabilized DC wall wart 5V/1A with jumper JP12 installed or use internal 5V power connector PL2.


Detailed information on HX3 usage can be found on '''[[Bedienungshinweise]]''' page (sorry, german language - use Google translation service).
HX3 should be installed by a qualified technician only. You should be familiar with ribbon cable mounting, crimp contact installation and soldering of delicate parts. Important: Boards contains static sensitive components. Be sure to use anti-static tools and grounded soldering toolset.  


==Installation==
HX3 board has standard firmware and licences installed from factory. However, you have to configure it to your own needs with '''[[HX3 Remote Application]]''' (drawbar and potentiometer enables and routing, scan board used). In some cases, you have to upload a special firmware (for latching presets, single manual organs or use of older Preset 24 board). You will need the [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/usbcable USB adaptor cable], the [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/hx3-extension HX3 Extension board] or an [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/usbif USB interface] to configure or update the HX3 board.
 
===First Steps===


HX3 should be installed by a qualified technician only. You should be familiar with ribbon cable mounting, crimp contact installation and soldering of delicate parts. Important: HX3 contains static sensitive components. Be shure to use anti-static tools and grounded soldering toolset.  
Connect '''PL2''' power connector to +5V stabilized DC supply, capable of at least 300mA. Be sure not to swap polarity; follow silk print on circuit board! You may alternatively use a wall wart type 5V supply with jumper '''JP12''' (near DC jack) installed or 9 to 12V with jumper '''JP12''' removed. Voltage regulator must be mounted to small heat sink for the latter case '''on older mk2 and mk3''' boards. '''PL2''' must not be used with external power applied to DC jack. Overvoltage or interchanged polarity will destroy HX3 circuitry. On new HX3 mk4 boards, 9-12V DC input is also available on PL2. Use '''either''' 5V '''or''' 9-12V input for supply. Remove jumper '''JP12''' (near DC jack) when using 9-12V DC input.  


Please refer to [https://github.com/heise/HOAX/blob/master/PLATINEN/HOAX3_mainboard/HOAX3_2_parts_top_en.pdf?raw=true board placement diagrams] in [https://github.com/heise/HOAX our Github repository], directories PLATINEN (PCBs) and DOCS_PDF. You should have received your board with proper firmware installed and configurated for your key scanning board or MIDI input only. If you ordered a kit from distributor '''segor''', follow soldering instructions on page [[Inbetriebnahme der Bausatz-Platine]] (sorry, german only).
After connecting power, LED1 (red) should light up for a few seconds, subsequentially followed by LED2 (yellow) flickering. If LED1 (red) blinks fast for a while or LED2 (yellow) does not light up, FPGA image data in flash memory has been tampered or is corrupted. Please return HOAX to manufacturer for repair or re-install firmware and FPGA configuration. Flickering or "breathing" yellw LED2 shows that HX3 sound engine (FPGA configuration) is working.  


First Test: Connect '''PL2''' power connector to +5V stabilized DC supply, capable of at least 300mA. Be shure not to swap polarity; follow silk print on circuit board! You may alternatively use a wall wart type 5V supply with jumper '''JP12''' (near DC jack) installed or 9 to 12V with jumper '''JP12''' removed. Voltage regulator must be mounted to small heat sink for the latter case. '''PL2''' must not be used with external power applied to DC jack. Overvoltage or interchanged polarity will destroy HX3 circuitry.  
For normal operation, '''jumper JP6''' (on mk2 boards), '''jumper REF''' (on mk3 boards) or '''JP9''' (on mk4 boards) must be inserted, despite JP12 for 5V operation of DC jack. '''Remove jumpers JP7 and JP8'''.


After connecting power, LED1 (red) should light up for a few seconds, subsequentially followed by LED2 (yellow) flickering. If LED1 (red) blinks fast for a while or LED2 (yellow) does not light up, FPGA image data in flash memory has been tampered or is corrupted. Please return HOAX to manufacturer for repair. Flickering or "breathing" LED2 (on HOAX2) shows that HOAX engine is working. Switch off before connecting anything else.
Use AGND and DGND pins as a "jumper rest" for spare jumpers. Switch off before connecting anything else.


For normal operation, only JP6 must be inserted as required (MONO/2-CHANNEL), despite JP12 for 5V operation of DC jack. Use AGND and DGND pins as a "jumper rest" for spare jumpers.
You may omit those switches/connections/drawbars/pots you don’t plan to use. Analog inputs (drawbars/pots) should be tied to ground or to fixed level (use of trimpot) if not used, otherwise they will "float" and change sound randomly, even with preset active.
HX3 may also be used '''without any switches/drawbars/pots''' connected by selecting "No Analog Inputs" in HX3 Remote parameter 478 (Expander Mode) - see page [[Using HX3 with MIDI controllers]]. You may leave all internal connectors open if you plan to remote by MIDI only with analog control inputs disabled.  


'''Only connect/disconnect cables or optional boards when power is off!'''  
'''Only connect/disconnect cables or optional boards when power is off!'''  


Please see [[Using HX3 with MIDI controllers]] for further details on MIDI implementation. You may leave all drawbar/pot/switch connectors open if you plan to remote by MIDI only with analog control inputs disabled.
Please refer to board placement diagrams (*_silk) in [https://github.com/keyboardpartner/HX3 our Github repository], directories PLATINEN (PCBs) and DOCS_PDF. Also visit '''[[HX3 mk3/mk4 additional info]]''' page for mk2/mk3/mk4 differences.
 
===Older HX3 mk2 Boards===
 
Older mk2 boards differ in serveral ways from current production, although board size, connector positions, FPGA configuration and Scan Core (parts of firmware package) are compatible. HX3 mk2 boards do not have a 26-pin header for extension boards. Otherwise, they have 4 audio output channels already on board, routed to two stereo jacks.
 
2-way jumper JP6 on older mk2 boards sets MAIN/BASS output jack either to MONO or to 2-channel output (separate pedal bass on plug ring). Set JP6 to 2-CHANNEL (opposite to MONO) to use newer firmware. '''JP12''' disables internal 5V voltage regulator for use with 5V power supplies on DC jack. Remove JP12 if using 9 to 12V power on DC jack. When ordered as kit, the "HW Test" scan core is still active and a full "C" chord should appear on organ main and Leslie audio outputs. If OK, change scan core with ''HX3 Remote''.
 
HX3 mk2 had separate tab stop switch inputs and button inputs. On mk3/mk4, button inputs alternatively act as switch inputs with appropiate ButtonMask setting in HX3 Remote. See "Connecting Digital Inputs" section for details.
 
HX3 mk2 boards require a different controller firmware, not compatible with mk3/mk4. Be sure to use "HX3'''mk2'''_*.hex" files when updating your mk2 board with ''HX3 Remote''.
 
==Connecting Analog Inputs==
 
HX3 provides 24 analog inputs, all located on pin headers PL9 and PL13. All analog inputs are DC controlled. Input voltage range is from 0V (off or minimal volume) to +3.3V (max. volume).  HX3 may also be used '''without any switches/drawbars/pots connected''' by installing the MIDI Expander firmware. You may leave all internal connectors open if you plan to remote by MIDI only with analog control inputs disabled. Note: One analog input is internally tied to SWELL jack and should remain open.


===Connecting Drawbars===
===Connecting Drawbar 9/11/12 Boards===


[[Datei:Db9mpx2.JPG|300px|thumb|right|'''Lower manual configuration with Drawbar12 (A# preset key, left) and Drawbar9-MPX (B preset key, right). Connects to HX3 via long flat ribbon cable (right). Upper manual configuration is similar, but uses Drawbar9 or Drawbar11 instead of Drawbar12.''']]
[[Datei:Wiring_drawbars.png|300px|thumb|right|'''Drawbar and pot connection to PL9 and PL13 (click picture to enlarge)''']]
[[Datei:Wiring_drawbars.png|300px|thumb|right|'''Drawbar and pot connection to PL9 and PL13 (click picture to enlarge)''']]


At least connect 9 drawbars or slider pots and volume control pot to '''PL9 Analog upper'''. R value should be in the 10kOhm to 47kOhm range, taper B (audio). All inputs are DC controlled. Input voltage range is from 0V (off or minimal volume) to +3.3V (max. volume). Connect MAIN/BASS audio output to amplifier. Level is in the 300 mV range.
Connection to our [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Categories/Category1/Register_und_PresetPlatinen drawbar boards Drawbar9 and Drawbar12] is very simple: Drawbar9 (upper) connects to '''PL9''', Drawbar12 (lower) connects to '''PL13''' via 16-wire flat ribbon cable (length up to 1m, plugs wired 1:1). Drawbar9 provides 3-pin headers for connection of Tone and Amp122 Volume pots; may be disabled by ''HX3 Remote'' parameter 481 if adusted by MenuPanel. Additional Drawbar9-MPX boards may be inserted for "two drawbar sets per manual" configurations. Note that Drawbar9-MPX must be the right drawbar set for each manual as on Hammond Consoles (see picture).


Loud noise may be heard on MAIN/BASS output if you ordered HOAX with Fatar scan board firmware driver, as no scan board is connected yet. Otherwise, connect a MIDI keyboard to MIDI in (PL18/PL20). HX3 accepts MIDI channel 1 for upper, channel 2 for lower (both 61 notes C-C) and channel 3 for bass (25 notes C-C). Plain organ sound should be heard when playing on channel 1. Check function of all drawbars. HX3 will accept MIDI controller messages conforming to MIDI CC setting (5 to choose from). Important: You may omit those switches/connections/drawbars/pots you don’t plan to use.  
Drawbar9 and Drawbar11/12 are compatible and interchangeable, despite additional drawbars for bass pedals resp. tone/amp volume.
 
Note to '''HX3 mk2/mk3''' users: Older HX3 boards do not provide a drawbar set switching signal for Drawbar 9-MPX on Pin 15 of PL9 and PL13. From firmware #3.925 and up, switching signals are provided on vibrato knob port PL5 (otherwise unused) pin 6 (upper manual drawbars) and pin 7 (lower). You have to route two single wires from these pins to each PL43 of Drawbar9-MPX (middle pin).
 
===Connecting other Drawbar Pots===
 
You may also use your own or existing drawbars as follows: At least connect 9 drawbars or slider pots and Leslie volume control pot to '''PL9 Analog upper'''. R value should be in the 10 kOhm to 47 kOhm range, '''linear taper''' (for example type B10K). Note that using audio taper (log.) drawbar pots as found in various older LSI and transistor organs will not yield correct loudness and drawbar position on MenuPanel display.  
 
From firmware revision 3.7 up there are special versions for use in '''single drawbar set''' organs. In this case, drawbars must be connected to '''PL13''' (Lower). Single drawbar set is assigned automatically to manual (or split section) which is currently played (or was used last). On '''PL9''', only input pins 10 and 11 are used (Tone und Amp Volume; may be disabled by ''HX3 Remote'' parameter 481 if adusted by MenuPanel).  


[[Datei:Hoax_rotary.png|300px|thumb|right|'''Vibrato rotary switch connection to PL5. First contact lug is not used!''']]
[[Datei:Hoax_rotary.png|300px|thumb|right|'''Vibrato rotary switch connection to PL5. First contact lug is not used!''']]
Zeile 66: Zeile 76:
8: Drawbar 1 1/3<br>
8: Drawbar 1 1/3<br>
9: Drawbar 1<br>
9: Drawbar 1<br>
10: Tone Pot (by special order only)<br>
10: Aux/Tone Pot<br>
11: Leslie Volume Pot (HOAX3 only)<br>
11: Amp Pot, simulated rotary tube amp volume<br>
12: Swell Pedal (no connect if jack used on HOAX3; may also be disabled by special order)<br>
12: Swell Pedal (do not connect if swell jack used)<br>
13, 14: Drawbar/Pot Gnd<br>
13, 14: Drawbar/Pot common Ground<br>
15, 16: Drawbar/Pot End 3.3V+ (Reference)<br>
15: Drawbar set A/B switch signal (mk3/mk4 boards only; may be tied to pin 16)<br>
16: Drawbar/Pot End 3.3V+ (Reference)<br>


'''PL13 Analog Controller B (Lower Manual)<br>'''
'''PL13 Analog Controller B (Lower Manual)<br>'''
Zeile 86: Zeile 97:
11: Drawbar Bass 8<br>
11: Drawbar Bass 8<br>
12: Drawbar/Pot Bass Sustain<br>
12: Drawbar/Pot Bass Sustain<br>
13, 14: Drawbar/Pot Gnd<br>
13, 14: Drawbar/Pot common Ground<br>
15, 16: Drawbar/Pot End 3.3V+ (Reference)<br>
15: Drawbar set A/B switch signal (mk3/mk4 boards only; may be tied to pin 16)<br>
16: Drawbar/Pot End 3.3V+ (Reference)<br>


DC swell/volume control is active also on pin 12 of PL9. Even with MIDI control, a swell pedal should be connected to SWELL jack. This overrides MIDI volume control. You may connect a swell pedal like Yamaha FC-7 or a simple volume pot to the SWELL jack.
DC swell/volume control is active also on pin 12 of PL9. Even with MIDI control, a swell pedal should be connected to SWELL jack. This overrides MIDI volume control. You may connect a swell pedal like Yamaha FC-7 or a simple volume pot to the SWELL jack. Do not connect pin 12 of PL9 if swell jack used.


HX3 may be ordered with tone/treble control input active. Tone pot center is connected to pin 10 of PL9. If digital Leslie emulation is licenced on HX3, pin 11 becomes the Leslie amp volume/drive control (mandatory). Both pots begin with Gnd and end with Ref 3.3V+.  
HX3 mainboard is set to tone/treble and amp volume control inputs active by factory (may be altered also with ''HX3 Remote'' or MenuPanel). Tone pot center is connected to pin 10 of PL9. If digital Leslie emulation is licenced on HX3, pin 11 becomes the Leslie amp volume/drive control (mandatory).  Amp volume pot center is connected to pin 11 of PL9. Both pots begin with Gnd and end with Ref 3.3V+.


===Connecting Switches or Buttons===
Please note: Open analog inputs (unconnected) will "float" and change randomly, even with presets active. '''Tie unused inputs to ground or fixed level''' (ie. trimpot).
 
==Connecting Digital Inputs==
 
HX3 mk3/mk3 provides 16 digital inputs plus one rotary swich input. Switches are defined as tab stops, rocker or toggle switches, buttons are momentary switch contacts, normally open. All inputs are active low, i.e. tie to ground when switch/button is operated.
 
===Panel 16===
 
Easiest solution for a register/stop panel is using [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/panel16 our Panel 16 board] connected to '''PL7 and PL11''' by two 10-wire flat ribbon cables. '''Panel 16''' provides 16 buttons for complete HX3 control; just add the rotary switch for vibrato depth.
 
Panel 16 has 4 "Common Preset" buttons, common to upper and lower manual. They may be used as buttons selecting V1-V3 vibrato or C1-C3 Chorus depth by updating your HX3 to "Button Vibrato" (_btnvib) firmware. In this case, omit the vibrato rotary switch.
 
Panel 16 PCB may be cut along "CUT HERE" line to get separate sections with 8 buttons each.
 
===Other Buttons or Switches===
 
Instead of Panel 16 you may also connect your own buttons or tab switches (up to 16). Every function is activated by either a button on digital inputs PL7/PL11 or a switch on PL8/PL12 (mk2 only). A momentary contact to ground on each PL7/PL11 pin will toggle it's status and drive indicator LEDs (see schematic). Leave unused digital inputs open.
 
Newer mk3 and mk4 boards do not provide additional switch inputs. To use tab stop switches on mk3/mk4 boards, define PL7 and PL11 inputs as switches with ''HX3 Remote Application'', "Organ defaults" parameter page. Check boxes in "ButtonMask" parameter row 479 and 480 to define an input pin as a '''switch instead of a button'''. The rightmost check box represents Pin 1 and so forth, up to leftmost box for pin 8. When using buttons, an indicator LED should be installed as shown; otherwise there is no indication if a tab stop is on or off.
 
For '''mk2''' boards, Pin functions of PL8/PL12 are equivalent to PL7/PL11, but provide separate tab stop switch inputs. Strictly use PL7/PL11 as button/LED inputs and PL8/PL12 as switch inputs with same functionality. Parameters 479 and 480 are invalid here.


Vibrato/chorus V1 to C3 is selected by a rotary switch:
Vibrato/chorus V1 to C3 is selected by a rotary switch:


'''Pins PL5 Vibrato rotary switch<br>'''
'''Pinout PL5 Vibrato rotary switch<br>'''
Pin Number - Function (active low – switch to Gnd)<br>
Pin - function (active low – switch to Gnd)<br>
nc: Vib1 (no connection)<br>
nc: Vib1 (no connection)<br>
1: Cho1<br>
1: Cho1<br>
Zeile 111: Zeile 143:
10: Common Gnd<br>
10: Common Gnd<br>


'''Pins PL7 buttons (momentary contact, optional LED) or PL8 tab switches<br>'''
Four "Common Preset" inputs (common to upper and lower manual) on PL11 may be used as buttons selecting V1-V3 vibrato or C1-C3 Chorus depth by updating your HX3 to "Button Vibrato" (_btnvib) firmware. In this case, omit the vibrato rotary switch.
Pin Number - Function (active low – switch to Gnd)<br>
 
'''Pinout PL7 buttons (momentary contact, optional LED)''' or PL8 tab/rocker switches on mk2 boards<br>
Pin - function (active low – switch to Gnd)<br>
1: Perc ON, like B3<br>
1: Perc ON, like B3<br>
2: Perc SOFT<br>
2: Perc SOFT<br>
Zeile 124: Zeile 158:
10: Common Gnd<br>
10: Common Gnd<br>


Up to 16 buttons or tab switches may be connected to PL7, PL11 or PL11/PL12. You may either use a buttin or a tab switch for each function, also mixed, but not both on same function.
'''Pinout PL11 buttons (momentary contact, optional LED)''' or PL12 tab/rocker switches on mk2 boards<br>
 
Pin - function (active low – switch to Gnd)<br>
'''Pins PL11 buttons (momentary contact, optional LED) or PL12 tab switches<br>'''
1: Common Preset 1 (only '''button''' on PL11 - do not use pin 1 of PL12!)<br>
Pin Number - function (active low – switch to Gnd)<br>
2: Common Preset 2 (only '''button''' on PL11 - do not use pin 2 of PL12!)<br>
1: Common Preset 1 (only '''button''' with LED indicator on PL11 - do not use pin 1 of PL12!)<br>
3: Common Preset 3 (only '''button''' on PL11 - do not use pin 3 of PL12!)<br>
2: Common Preset 2 (only '''button''' with LED indicator on PL11 - do not use pin 1 of PL12!)<br>
4: Common Preset 4 (only '''button''' on PL11 - do not use pin 4 of PL12!)<br>
3: Common Preset 3 (only '''button''' with LED indicator on PL11 - do not use pin 1 of PL12!)<br>
4: Common Preset 4 (only '''button''' with LED indicator on PL11 - do not use pin 1 of PL12!)<br>
5: EFX 1 / Reverb 1<br>
5: EFX 1 / Reverb 1<br>
6: EFX 2 / Reverb 2<br>
6: EFX 2 / Reverb 2<br>
Zeile 139: Zeile 171:
10: Common Gnd<br>
10: Common Gnd<br>


Every function may be activated by a button on PL7/PL11 or a switch on PL8/PL12. Pin functions are equivalent, but PL7/PL11 toggle status on every push and drive indicator LEDs (see schematic). You may omit those switches you don’t plan to use or connect corresponding pins of PL8 and PL12 permanently to Gnd if function should be ON as default.
==Connecting Presets==


A button panel named Panel16 with 16 LED buttons is available if you want to have a hassle-free compact solution. It connects directly to PL7 and PL11. It also contains the 4 common preset buttons.
HX3 board does provide 4 "common" presets (see '''Pinout PL11''') for both upper and lower manual. It may be extended to 2x8, 2x12 or 2x16 presets with optional boards Preset 12 (obsolete), '''Preset 12-2''', '''Preset 16''' (one or two) or Preset 24 (obsolete). All connect to '''HX3 PL4''' by 10-wire flat ribbon cable. HX3 PL4 is a I2C bus system, so all boards connect in parallel (use multiple 10-pin plugs on one cable if necessary); Preset12 and Preset16 yield an extension route-through connector for adding more boards. Cable length on HX3 PL4 should not exceed 75 cm (30") in total. Use appropriate firmware for each preset solution. See description of each product for details. Obsolete boards are still supported by newer firmware issues.


===Connecting Preset Switches===
===Preset 16===


HX3 may be extended to 2x8, 2x12 or 2x16 presets with optional boards '''Preset12''' (obsolete), '''Preset16''' (one or two) or '''Preset24'''. All connect to '''HX3 PL4''' by 10-wire flat ribbon cable. HX3 PL4 is a I2C bus system, so all boards connect in parallel (use multiple 10-pin plugs on one cable if necessary); Preset12 and Preset16 yield an extension route-through connector for adding more boards. Cable length on HX3 PL4 should not exceed 75 cm (30") in total. See description of each product for details.
[[Datei:Panel16 anschl.JPG|300px|thumb|right|'''Two daisy-chained Preset 16 boards connected to PL4. Optional MenuPanel may be connected to last Preset16 board.''']]


==Optional Boards==
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/preset16 Preset 16] is a self-contained panel with 2 rows of 8 LED buttons each. It connects to '''HX3 PL4''' by a 10-wire flat ribbon cable. A second Preset 16 may be connected to second 10-pin header (daisy-chain). Both 10-pin headers on Preset16 may be used (are wired in parallel). A jumper set on Preset 16 selects upper manual. If jumper is absent, Preset16 works on lower manual.


===Connecting MenuPanel===
If only one Preset 16 is connected, jumper JP1 must be set. Now upper row of buttons is for upper manual, lower row for lower manual (i.e. 8 presets each). This preset split function may be overridden by param 484 in HX3 Remote set to ON.
[[Datei:MenuPanel_full.JPG|300px|thumb|right|'''HX3 MenuPanel''', fitted with optional LEDs]]
 
If using 2 sets of drawbars per manual by DB9-MPX drawbar board board, set ''HX3 Remote'' "Organ Defaults" parameter 483 "2nd Drawbar Set" to 1. This will activate 1st drawbar set on Preset 0, 2nd drawbar set on Preset 1.
 
===Preset 12-2===
 
'''[[Datei:Preset12-2_ansch.JPG|300px|thumb|right|Preset 12-2 board connects to HX3 PL4. Flat ribbon cable may be extended with additional connector to accomodate MenuPanel.]]'''
 
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/preset12-2 Preset 12-2] is an interface board for up to 2 x 12 "inverted" preset keys (with optional LED indicators) as found on Hammond console organs. Preset 16 PCB is similar to Panel 16, but has additional circuitry and connects to '''HX3 PL4''' by a 10-wire flat ribbon cable. See schematics for pin designation. Pin 1 of both 14-pin headers is Preset 0 = Live (right drawbar set) = B key, pin 2 is Preset 1 = Live (left drawbar set) etc. downto pin 12 = CANCEL key.
 
Standard organ firmware supports '''momentary contacts'''. To save a preset, press and hold preset key/button for 2 seconds.
 
For '''latching''' keys (original Hammond keybeds), use "Latching" type firmware. Save a preset by pressing CANCEL key (i.e. Preset 11) and then destination preset key, hold both for 2 seconds and release CANCEL.
 
If using '''2 sets of drawbars per manual''' by DB9-MPX drawbars/multiplexer and Preset12-2 board, set ''HX3 Remote'' "Organ Defaults" parameter 483 "2nd Drawbar Set" to 1.
 
'''Pinout PL1 (LEDs)'''<br>
Pin - function<br>
1: LED 1 cathode (Preset 0, "B" key drawbar set)<br>
2: LED 2 cathode (Preset 1, "A#" key drawbar set)<br>
3: LED 3 cathode (Preset 2)<br>
...<br>
12: LED 12 cathode (Preset 11, CANCEL key)<br>
13,14: Common LED anode (+)
 
LED outputs have on-board 220 Ohms resistors, resulting in 15 mA LED current. Long leg of LEDs is anode (+), short leg is cathode (-).
 
'''Pinout PL2 (Buttons/Switches)'''<br>
Pin - function (active low – switch to Gnd)<br>
1: Switch 1 (Preset 0, "B" key drawbar set)<br>
2: Switch 2 (Preset 1, "A#" key drawbar set)<br>
3: Switch 3 (Preset 2)<br>
...<br>
12: Switch 12 (Preset 11, CANCEL key)<br>
13,14: Common switch ground (0V)
 
Note: The old '''Preset12-MPX''' boards for HX3 mk2/mk3 may be used as well for HX3 mk4 and mk5. They do not offer a variable preset number for second drawbar set, though. Instead, second drawbar set is hard-wired to Voice Preset 15. So you have to change 2nd drawbar set number in parameter #1496 (HX3.5) resp #496 (HX3.4) to 15, not to 1.
 
==Connecting Keyboard Scan Board(s)==
 
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Use ''HX3 Remote application'', "Organ Defaults" parameter 477 to set appropriate scan board driver (so called Scan Core) for board used. However, HX3 may be controlled by MIDI key ON/OFF messages from any keyboard by using Scan Core 1 (MIDI input) without any scan board connected.
 
Scan Cores will support MIDI input/output too, but for MIDI remote we recommend MIDI input driver as this one has the most versatile transposing and octave shifting features, supporting the full range of 88 key manuals.
 
===FatarScan2===
'''[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2 connection diagram]]''' 
 
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to '''HX3 PL14'''. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (german) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).
 
Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to '''HX3 PL15''' (!). FatarScan2 board is are activated by ''HX3 Remote application'', "Organ Defaults" parameter 477.
 
===Bass25===
[[Datei:Midibass25.JPG|300px|thumb|right|'''Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply''']]
 
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] scan board (refer to PDFs in [https://github.com/heise/HOAX/tree/master/PLATINEN/Bass25 our Github repo folder PLATNEN/BASS25]) may be used as an addition to FatarScan2, OrganScan61, Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). Board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:
 
'''Old version''' (beige PCB):
* '''JP6''' inserted always
* '''JP7 2-3''' inserted if OrganScan61 (daisy chain on '''HX3 PL14'''), Bass25 to last OrganScan61 board
* '''JP7 1-2''' inserted if FatarScan2 on '''HX3 PL14''', or Scan16 Strip and Bass25 to '''HX3 PL15'''
* '''JP8 2-3''' inserted always


Connect optional '''[[HX3 MenuPanel]]''' to '''HX3 PL4''' using a 10-wire flat ribbon cable. HX3 firmware from version 3.41 and up will recognize the MenuPanel and act accordingly. [[HX3 MenuPanel]] may be used in parallel/simultaneously with Preset12 (obsolete), Preset16 and Preset24 boards connected to '''HX3 PL4'''. Extend a flat ribbon with additional connector to your cable on '''HX3 PL4''' or use unoccupied 10-pin header on (last) Preset16 board which also carries the PL4 signal.
Contacts always switch to ground (busbar).


===Connecting OrganScan61 board set===
'''New version''' MIDISCAN25 (green PCB):
'''[[Datei:wiring_os61.png|300px|thumb|right|Connection diagram of OrganScan61 (click picture to enlarge)]]'''
* '''JP1''' solder bridge, always open
* '''JP2''' solder bridge if used with OrganScan61 (daisy chain on '''HX3 PL14'''), Bass25 to last OrganScan61 board
* '''JP3''' solder bridge if used with FatarScan2 on '''HX3 PL14''' or Scan16 Strip on '''HX3 PL15'''


A set of up to 3 "daisy-chained" OrganScan61 boards are connected to PL14 if HOAX was ordered with OrganScan61 firmware driver. Refer to picture. Be shure not to twist connectors (red marked ribbon lead must match with pin 1 of all ribbon cable connectors, indicated by a triangle marking). Total cable length should not exceed 1,5m. First board in row is upper manual, second is lower manual and third (rightmost in picture) is bass pedal (not completely populated since only 25 keys are present). Bass25 board may be used as an alternative to last OrganScan61 board; it has the same functionality (but different key connectors). See page [[Anschluss der Scan-Platine OrganScan61 (KlangComputer)]] (german) for more pictures.
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:


Inputs are active low (switch to ground), so connecting them to Gnd pins 13 to 16 of PL33 (PL31 on bass) on OrganScan61 board should yield the appropriate note. See OrganScan61 schematic for connector pinout.  
Pin - function (active low switch to Gnd)<br>
1: Lowest note "C"<br>
...<br>
25: Highest note "C"<br>
26: Common ground (busbar)


'''Keybed Connection<br>'''
'''JP3 and JP4''' solder bridges must be closed. 2-pin inline header PL9 also provides common ground for the busbar.
Pin 1 PL30 = Note 1 = lowest C 1<br>
Pin 16 PL30 = Note 16 = D# 2<br>


Pin 1 PL31 = Note 17 = E 2<br>
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.
Pin 16 PL31 = Note 32 = G 3<br>


Pin 1 PL32 = Note 33 = G# 3<br>
===Bass25 MIDI===
Pin 16 PL32 = Note 48 = H 4<br>


Pin 1 PL33 = Note 49 = C 5<br>
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to HX3 mk3/mk4 main board by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.
Pin 13 PL33 = Note 61 = C 6<br>
Pin 14, 15, 16 PL33 = Gnd/Busbar<br>


'''Pedals Connection<br>''' (or use Bass25 scan board)
Pin - function (active low – switch to Gnd)<br>
Pin 1 PL30 = Note 1 = lowest C 1<br>
1: Lowest note "C"<br>
Pin 16 PL30 = Note 16 = D# 2<br>
...<br>
25: Highest note "C"<br>
26: Common ground (busbar)


Pin 1 PL31 = Note 17 = E 2<br>
'''JP3''' solder bridge must be closed.
Pin 9 PL31 = Note 25 = C 2<br>
Pin 14, 15, 16 PL31 = Gnd/Busbar<br>


If unconfigured, OrganScan61 boards are activated by serial command:
'''JP4''' solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted (mk3 and mk4 boards only).


wen=1
For separate power supply (internal +5V or external 9V DC wall wart), open '''JP4''' solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground (refer to PDF schematics in [https://github.com/heise/HOAX/tree/master/PLATINEN/Bass25 our Github repo folder PLATNEN/BASS25]).
519=0


Refer to serial interface command description [https://github.com/heise/HOAX/blob/master/DOCS_PDF/HOAX3_Syntax.xls?raw=true (syntax table)], Excel sheet in [https://github.com/heise/HOAX our Github repository], directory DOCS_PDF.
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two '''additional''' jumpers on HX3 PL10 '''pins 7-8 and 9-10'''. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.


===Connecting Scan16 board set===
===Scan16-Strip Set===
'''[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 to HX3 board.]]'''
'''[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 to HX3 board.]]'''


As an alternative to OrganScan61 a set of Scan16 strip boards may be used which yields easier installation on some keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) strip boards. Please refer to [https://github.com/heise/HOAX/tree/master/PLATINEN schematics and part placement] in out Git repo. Connection is somewhat different to OrganScan61: All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to '''HX3 PL15'''. Bass25 may be used as convenient alternative to pedal scan board. A jumper on "lowest" Scan16 board determines if keybed is upper, lower or bass pedal:
As an alternative to old OrganScan61 one or two sets of tall [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on some keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/heise/HOAX/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to '''HX3 PL15'''. Bass25 may be used as pedal scan board. A jumper on "lowest" Scan16 board determines if keybed is upper, lower or bass pedal:


JP1 = Upper manual<br>
JP1 = Upper manual<br>
Zeile 199: Zeile 291:
JP3 = Pedal notes<br>
JP3 = Pedal notes<br>


If unconfigured, Scan16 boards for one or two 61-key manuals are activated by serial command:
Please note: lowest key contact pad on Scan16 is always "C" key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with "F" key. On 49-key manuals, connect pad PL20 to highest "C" note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.


wen=1
Scan16 boards for one or two 49/61-key manuals is are activated by ''HX3 Remote application'', "Organ Defaults" parameter 477.
519=5


Scan16 boards for one or two 49-key manuals (spinett type organs) are activated by serial command:
===Scan61-Inline===
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|'''Scan61-Inline Board connected to HX3 mk4''']]


wen=1
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] works exactliy like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [https://github.com/heise/HOAX/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to '''HX3 PL15'''. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:
  519=4


Please note: lowest key contact pad on Strip16 is always "C" key. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with "F". On 49-key manuals, connect pad PL20 to highest "C" note.
JP1 = Upper manual<br>
JP2 = Lower manual<br>
JP3 = Pedal notes<br>


As on OrganScan61, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.
Please note: lowest key contact pad on Strip61-Inline is always "C" key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.


===Connecting FatarScan2 board===
Scan61-Inline boards are activated by ''HX3 Remote application'', "Organ Defaults" parameter 477, set to Scan16/61.
'''[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2 connection diagram]]'''
 
===OrganScan61 Board Set===
 
'''Obsolete, for reference only!'''
 
'''[[Datei:wiring_os61.png|300px|thumb|right|Connection diagram of OrganScan61 (click picture to enlarge)]]'''
 
A set of up to 3 "daisy-chained" OrganScan61 boards are connected to PL14 if HOAX was ordered with OrganScan61 firmware driver. Refer to picture. Be shure not to twist connectors (red marked ribbon lead must match with pin 1 of all ribbon cable connectors, indicated by a triangle marking). Total cable length should not exceed 1,5m. First board in row is upper manual, second is lower manual and third (rightmost in picture) is bass pedal (not completely populated since only 25 keys are present). Bass25 board may be used as an alternative to last OrganScan61 board; it has the same functionality (but different key connectors). See page [[Anschluss der Scan-Platine OrganScan61 (KlangComputer)]] (german) for more pictures.
 
Inputs are active low (switch to ground), so connecting them to Gnd pins 13 to 16 of PL33 (PL31 on bass) on OrganScan61 board should yield the appropriate note. See OrganScan61 schematic for connector pinout.


A single FatarScan2 board is connected to '''HX3 PL14'''. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (german) for more pictures. We recommend buying to FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds; see page [[Anschluss der Scan-Platine FatarScan2]] (german) for more pictures.
'''Keybed Connection<br>'''
Plug/Pin - function (active low – switch to Gnd)<br>
PL30/1:  Note 1 = lowest C 1<br>
PL30/16: Note 16 = D# 2<br>


Bass pedals may be connected to an additional OrganScan61, OrganScan16 or Bass25 board wired to '''HX3 PL15''' (!). FatarScan2 board is are activated by serial command:
PL31/1: Note 17 = E 2<br>
PL31/16: Note 32 = G 3<br>


wen=1
PL32/1: Note 33 = G# 3<br>
519=2
PL32/16: Note 48 = H 4<br>


Refer to serial interface command description [https://github.com/heise/HOAX/blob/master/DOCS_PDF/HOAX3_Syntax.xls?raw=true (syntax table)], Excel sheet in [https://github.com/heise/HOAX our Github repository], directory DOCS_PDF.
PL33/1: Note 49 = C 5<br>
PL33/16: Note 61 = C 6<br>
PL33/14,15,16: Gnd/Busbar<br>


===Connecting LDR/Leslie Interface Board===
'''Pedals Connection<br>''' (or use Bass25 scan board)<br>


The LDR/Leslie Interface (see german page [[LDR/Leslie-Interface-Platine]] and documents in [https://github.com/heise/HOAX/tree/master/PLATINEN/Adapter Github repo folder ADAPTER]) is required for direct connection of Leslie families 715, 760 and 147 without need of Combo Preamp. It contains a two-channel preamp for organ main (manuals) and pedals, a mixing stage and relais switches for Leslie control, also a power supply capable of 5V/500mA. This board is intended for skilled technicians, as it might require adjustments and re-wiring to fit your needs.
Plug/Pin - function (active low – switch to Gnd)<br>
PL30/1: Note 1 = lowest C 1<br>
PL30/16: Note 16 = D# 2<br>


Main channel is routed either from HX3 '''main organ output''' or Leslie '''tube amp simulation''' output (recommended for use with transistor Leslies) to LDR/Leslie Interface Board's preamp. A volume pot might be inserted between preamp and mixing stage. To control Leslie speed relais, 10-pin header connect to '''HX3 PL12''' (also additionally in parallel to other switches). Connection to '''HX3 PL7''' on second 10-pin header is required only when a Leslie button switch is to be used (momentary "button" contact, often found on organ's swell pedal).
PL31/1: Note 17 = E 2<br>
PL31/9: Note 25 = C 2<br>
PL31/14,15,16: = Gnd/Busbar<br>


Green power connector carries 5V DC to supply HX3 board, indicator LEDs on '''HX3 PL7/PL11''' (if installed) and optional MenuPanel. Note wire jumpers for '''117V or 230V mains''' and set operating voltage trimpot to 5.0V on green power connector.
OrganScan61 boards are activated by ''HX3 Remote application'', "Organ Defaults" parameter 477.


We recommend Yamaha FC-7 type expression pedal plugged into HX3 SWELL jack, but for OEM installations in older organ consoles the LDR-to-voltage converter on Leslie I/F board may also be used. It translates swell pedal's LDR resistance to swell control voltage of HX3. SWELL jack has to be removed for this purpose. LDR stage requires proper calibration of GAIN and OFS trimpots to obtain a control voltage range of approx. 0 (soft) to 3.3V (full swell) on HX3 swell input.
==Firmware Settings==


Other two trimpots set preamp gain. Adjust gain for full Leslie volume. We can supply a set of 3-wire cables with plugs to connect to HX3 audio and swell. Inportant: Plug polarity reqires 3-pin headers to be installed from HX3 component side instead of 1/4" jacks. If installed from solder side, reverse pinout accordingly. Leslie connection is described in [https://github.com/heise/HOAX/blob/master/PLATINEN/Adapter/schem_LDR_Leslie_IF_new.pdf?raw=true schematics of LDR/Leslie Interface Board].
Firmware type depends on preset board used and number of manuals. Factory default is Preset16/Preset12-2 standard organ firmware, two keybeds with drawbar set for each manual. Update your HX3 with '''[[HX3 Remote Application]]''' to different firmware if using a single drawbar set (no lower manual), latching preset keys or Preset24. Even with correct firmware installed, there are some settings that have to be done with ''HX3 Remote''. All parameters can be found in HX3 Remote's ''Organ'' defaults tab:


'''Connection of Leslie interface board to 11 pin Leslie'''
'''Parameter - Function'''<br>
{| border="1" cellpadding="8" cellspacing="0"
'''438/439 - Output Jack Configuration''' Routes 5 different signals to 2 (or 4 with extension board) audio output jacks (32 variants).<br>
|PL12-1
'''477 - Scan Core''' Set to scan board used in yout organ or to sole MIDI input.<br>
|PL12-2
'''478 - No Analog Inputs''' Set to ON (255) if no pots or drawbars connected. Drawbars are controlled by MIDI only.<br>
|PL12-3
'''479 - ButtonMask Pins PL7''' Check boxes for each PL7 pin that is connected to a switch instead of a button (applies to mk3 and mk4 boards).<br>
|PL12-4
'''480 - ButtonMask Pins PL11''' Check boxes for each PL11 pin that is connected to a switch instead of a button (applies to mk3 and mk4 boards).<br>
|PL10-1
'''481 - AMP Pot Enable''' When OFF, HX3 simulated rotary tube amp volume is controlled by MIDI or MenuPanel only. Set to ON (255) if simulated rotary amp is controlled by potentiometer on pin PL9 pin 11.<br>
|PL10-2
'''492 - AUX Pot Routing''' When OFF, HX3's TONE and MASTER VOLUME functions are controlled by MIDI or MenuPanel only. Set to 1 to route Aux analog input (PL9 pin 10) to TONE function. Set to 2 to route input to MASTER VOLUME function (firmware 3.925 and up).<br>
|PL10-3
'''483 - 2nd DBs Preset Number''' Default 16 (no second drawbar set per manual). Set to 1 if using Preset 16 or Preset 12-2 '''and''' two drawbar sets per manual '''with drawbar boards Drawbar 9/12 plus Drawbar 9-MPX'''. Set to 15 if using old '''Preset 24 or Preset 12 MPX''' boards.<br>
|Remark
|-
|Leslie pin 8 (slow)
|Leslie pin 7 (fast)
|Leslie pin 6 (power)
|Leslie pin 5 (common)
|Leslie pin 1 (rotary)
|Leslie pin 4 (Gnd)
|Leslie pin 2 (stationary)
|Set HOAX JP6 to STEREO
|}
<br>
'''Connection of Leslie interface board to 9 pin Leslie'''
{| border="1" cellpadding="8" cellspacing="0"
|PL12-1
|PL12-2
|PL12-3
|PL12-4
|PL10-1
|PL10-2
|PL10-3
|Remark
|-
|Leslie pin 7 (slow)
|Leslie pin 6 (fast)
|not connected
|Leslie pin 1 (Gnd)
|Leslie pin 2 (audio)
|Leslie pin 1 (Gnd)
|not connected
|Set HOAX JP6 to MONO
|}
<br>
'''Connection of Leslie interface board to 147 Leslie 6-pin'''
{| border="1" cellpadding="8" cellspacing="0"
|PL6-1+2
|PL6-4+5
|PL10-1
|PL10-2
|Remark
|-
|Leslie pin 4
|Leslie pin 5
|Leslie pin 6 (audio)
|Leslie pin 1 (Gnd)
|Set HOAX JP6 to MONO
|}
Note: Additional power relay recommended for 230V HV on 147 Leslie pin 4 and 5. Bridge pin 2 to pin 3 of Leslie 6-pin connector.


==Connecting Serial USB cable==
==Options==
[[Datei:ftdi.jpg|300px|thumb|right|'''FTDI cable connected to HX3''']]


For custom configuration, entering '''licence codes''' and FPGA/firmware updates, a USB-to-serial adaptor cable '''[http://www.ftdichip.com/Products/Cables/USBTTLSerial.htm FTDI TTL-232R 5V]''' must be used. Communication is established by simple clear-text commands by terminal emulation software [http://ttssh2.sourceforge.jp/ TeraTerm 4.7x] (recommended).
===MenuPanel===
[[Datei:MenuPanel_full.JPG|300px|thumb|right|'''HX3 MenuPanel''', fitted with optional LEDs]]


Parameters are 57600/8n1, send CR, receive CR+LF. As +5V is supplied by USB, external power supply may be disconnected. Do not use unpowered USB hubs as HOAX needs 250mA to run (note: on newer HX3 boards, 5V pin of PL26 may be cut off, HX3 power supply must be on). See '''HOAX3_syntax''' MS Excel table in [https://github.com/heise/HOAX our Github repository], directory DOCS_PDF, for command details. Update of FPGA configuration and scan cores are also done by TeraTerm macros in [https://github.com/heise/HOAX/tree/master/TERATERM_MACRO Github TERATERM_MACRO folder]. Update of firmware is done by AVRdude command batch "hoaxflash.bat".  
Our [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/menupanel MenuPanel] allows convenient adjustments of various HX3 parameters to tweak your setup. Two versions available, short one without indicator LEDs intended for organ installation.


Connect FTDI TTL-232 5V cable header to PL26 so black cable sits on GND pin and red cable sits on +5V pin. Plug in PL26 cable first, then connect to USB. Test connection by pressing ENTER a few times, HX3 should answer with "#0:255=0 [OK]" if connection os OK and cable driver properly installed. Please see page [[Inbetriebnahme der Bausatz-Platine]] for details on driver installation (sorry, german language - use Google translation service).
Connect HX3 MenuPanel to '''HX3 PL4''' using a 10-wire flat ribbon cable. HX3 firmware from version 3.41 and up will recognize the MenuPanel and act accordingly. HX3 MenuPanel may be used in parallel/simultaneously with Preset12-2, Preset16 and Preset24 boards connected to '''HX3 PL4'''.  


HX3 will restart on command
Extend a flat ribbon with additional connector to your cable on '''HX3 PL4''' or use unoccupied 10-pin header on (last) Preset16 board which also carries the PL4 signal. PL4 carries an I2C bus system where all devices are wired in parallel.


9999
See page '''[[HX3 MenuPanel]]''' for usage instructions.


and output some status messages. Restart every time you change scan routine setting like above. For example, MIDI only mode is invoked by serial command:
===Serial USB cable===
[[Datei:ftdi.jpg|300px|thumb|right|'''FTDI cable connected to HX3''']]


wen=1
HX3 board is configured and updated by serial connection through FTD USB adaptor cable or USB interface. '''See page [[HX3 Remote Application]]''' for details.
519=1


For AVR firmware update, make shure TeraTerm was working properly and quit. Place reset jumper to adjacent 10-pin header as shown on page [[Firmware- und FPGA-Update]]. Start "hoaxflash.bat" with your cable's COM port number (i.e. "hoaxflash 3" for COM3) and remove reset jumper same time. Supplied AVRdude utility will flash ATmega644 MCU with given file "MOAX_main.hex" and HOAX_main.eep" in your "C:\HOAX" directory. Do not try if you are not familiar with command line tools; same applies for updating the FPGA configuration and scan cores with TeraTerm macros. Refer to page [[Firmware- und FPGA-Update]] (sorry. german - use Google translation service).
===HX3 Extension Board===


==MIDI Usage==
The [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/hx3-extension HX3 extension board] for mk3/mk4 mainboards adds two additional audio outputs, Leslie(R) control and preamplifier for 9- and 11-pin Leslies, headphone jack, USB interface for parameter control to your HX3 mainboard. It also adds a MIDI OUT in case HX3 mk3 board is jumpered for two MIDI inputs. See '''[[HX3 Extension Board Installation]]''' for details.


Please see [[Using HX3 with MIDI controllers]] for further details on MIDI.
If the Extension board is installed, both MIDI jacks on mainboard should be jumpered as MIDI INs as the Extension board has its own MIDI OUT.

Aktuelle Version vom 8. November 2018, 16:53 Uhr

HX3 single-board sound engine for connecting any keyboard, for installation into existing organs or MIDI control

HX3 mk2 board ready for installation

Installation

Requirements

HX3 should be installed by a qualified technician only. You should be familiar with ribbon cable mounting, crimp contact installation and soldering of delicate parts. Important: Boards contains static sensitive components. Be sure to use anti-static tools and grounded soldering toolset.

HX3 board has standard firmware and licences installed from factory. However, you have to configure it to your own needs with HX3 Remote Application (drawbar and potentiometer enables and routing, scan board used). In some cases, you have to upload a special firmware (for latching presets, single manual organs or use of older Preset 24 board). You will need the USB adaptor cable, the HX3 Extension board or an USB interface to configure or update the HX3 board.

First Steps

Connect PL2 power connector to +5V stabilized DC supply, capable of at least 300mA. Be sure not to swap polarity; follow silk print on circuit board! You may alternatively use a wall wart type 5V supply with jumper JP12 (near DC jack) installed or 9 to 12V with jumper JP12 removed. Voltage regulator must be mounted to small heat sink for the latter case on older mk2 and mk3 boards. PL2 must not be used with external power applied to DC jack. Overvoltage or interchanged polarity will destroy HX3 circuitry. On new HX3 mk4 boards, 9-12V DC input is also available on PL2. Use either 5V or 9-12V input for supply. Remove jumper JP12 (near DC jack) when using 9-12V DC input.

After connecting power, LED1 (red) should light up for a few seconds, subsequentially followed by LED2 (yellow) flickering. If LED1 (red) blinks fast for a while or LED2 (yellow) does not light up, FPGA image data in flash memory has been tampered or is corrupted. Please return HOAX to manufacturer for repair or re-install firmware and FPGA configuration. Flickering or "breathing" yellw LED2 shows that HX3 sound engine (FPGA configuration) is working.

For normal operation, jumper JP6 (on mk2 boards), jumper REF (on mk3 boards) or JP9 (on mk4 boards) must be inserted, despite JP12 for 5V operation of DC jack. Remove jumpers JP7 and JP8.

Use AGND and DGND pins as a "jumper rest" for spare jumpers. Switch off before connecting anything else.

You may omit those switches/connections/drawbars/pots you don’t plan to use. Analog inputs (drawbars/pots) should be tied to ground or to fixed level (use of trimpot) if not used, otherwise they will "float" and change sound randomly, even with preset active.

HX3 may also be used without any switches/drawbars/pots connected by selecting "No Analog Inputs" in HX3 Remote parameter 478 (Expander Mode) - see page Using HX3 with MIDI controllers. You may leave all internal connectors open if you plan to remote by MIDI only with analog control inputs disabled.

Only connect/disconnect cables or optional boards when power is off!

Please refer to board placement diagrams (*_silk) in our Github repository, directories PLATINEN (PCBs) and DOCS_PDF. Also visit HX3 mk3/mk4 additional info page for mk2/mk3/mk4 differences.

Older HX3 mk2 Boards

Older mk2 boards differ in serveral ways from current production, although board size, connector positions, FPGA configuration and Scan Core (parts of firmware package) are compatible. HX3 mk2 boards do not have a 26-pin header for extension boards. Otherwise, they have 4 audio output channels already on board, routed to two stereo jacks.

2-way jumper JP6 on older mk2 boards sets MAIN/BASS output jack either to MONO or to 2-channel output (separate pedal bass on plug ring). Set JP6 to 2-CHANNEL (opposite to MONO) to use newer firmware. JP12 disables internal 5V voltage regulator for use with 5V power supplies on DC jack. Remove JP12 if using 9 to 12V power on DC jack. When ordered as kit, the "HW Test" scan core is still active and a full "C" chord should appear on organ main and Leslie audio outputs. If OK, change scan core with HX3 Remote.

HX3 mk2 had separate tab stop switch inputs and button inputs. On mk3/mk4, button inputs alternatively act as switch inputs with appropiate ButtonMask setting in HX3 Remote. See "Connecting Digital Inputs" section for details.

HX3 mk2 boards require a different controller firmware, not compatible with mk3/mk4. Be sure to use "HX3mk2_*.hex" files when updating your mk2 board with HX3 Remote.

Connecting Analog Inputs

HX3 provides 24 analog inputs, all located on pin headers PL9 and PL13. All analog inputs are DC controlled. Input voltage range is from 0V (off or minimal volume) to +3.3V (max. volume). HX3 may also be used without any switches/drawbars/pots connected by installing the MIDI Expander firmware. You may leave all internal connectors open if you plan to remote by MIDI only with analog control inputs disabled. Note: One analog input is internally tied to SWELL jack and should remain open.

Connecting Drawbar 9/11/12 Boards

Lower manual configuration with Drawbar12 (A# preset key, left) and Drawbar9-MPX (B preset key, right). Connects to HX3 via long flat ribbon cable (right). Upper manual configuration is similar, but uses Drawbar9 or Drawbar11 instead of Drawbar12.
Drawbar and pot connection to PL9 and PL13 (click picture to enlarge)

Connection to our drawbar boards Drawbar9 and Drawbar12 is very simple: Drawbar9 (upper) connects to PL9, Drawbar12 (lower) connects to PL13 via 16-wire flat ribbon cable (length up to 1m, plugs wired 1:1). Drawbar9 provides 3-pin headers for connection of Tone and Amp122 Volume pots; may be disabled by HX3 Remote parameter 481 if adusted by MenuPanel. Additional Drawbar9-MPX boards may be inserted for "two drawbar sets per manual" configurations. Note that Drawbar9-MPX must be the right drawbar set for each manual as on Hammond Consoles (see picture).

Drawbar9 and Drawbar11/12 are compatible and interchangeable, despite additional drawbars for bass pedals resp. tone/amp volume.

Note to HX3 mk2/mk3 users: Older HX3 boards do not provide a drawbar set switching signal for Drawbar 9-MPX on Pin 15 of PL9 and PL13. From firmware #3.925 and up, switching signals are provided on vibrato knob port PL5 (otherwise unused) pin 6 (upper manual drawbars) and pin 7 (lower). You have to route two single wires from these pins to each PL43 of Drawbar9-MPX (middle pin).

Connecting other Drawbar Pots

You may also use your own or existing drawbars as follows: At least connect 9 drawbars or slider pots and Leslie volume control pot to PL9 Analog upper. R value should be in the 10 kOhm to 47 kOhm range, linear taper (for example type B10K). Note that using audio taper (log.) drawbar pots as found in various older LSI and transistor organs will not yield correct loudness and drawbar position on MenuPanel display.

From firmware revision 3.7 up there are special versions for use in single drawbar set organs. In this case, drawbars must be connected to PL13 (Lower). Single drawbar set is assigned automatically to manual (or split section) which is currently played (or was used last). On PL9, only input pins 10 and 11 are used (Tone und Amp Volume; may be disabled by HX3 Remote parameter 481 if adusted by MenuPanel).

Vibrato rotary switch connection to PL5. First contact lug is not used!
Connection of buttons with LED indicators to PL7 and PL11
Alternative connection of tab swiches to PL8 and PL12, same function as buttons above
Connection of LED indicators to PL7/PL11, if tab switches used on PL8/PL12. Will also reflect preset setting of each function.

PL9 Analog Controller A (Upper Manual)
Pin - function
1: Drawbar 16
2: Drawbar 5 1/3
3: Drawbar 8
4: Drawbar 4
5: Drawbar 2 2/3
6: Drawbar 2
7: Drawbar 1 5/9
8: Drawbar 1 1/3
9: Drawbar 1
10: Aux/Tone Pot
11: Amp Pot, simulated rotary tube amp volume
12: Swell Pedal (do not connect if swell jack used)
13, 14: Drawbar/Pot common Ground
15: Drawbar set A/B switch signal (mk3/mk4 boards only; may be tied to pin 16)
16: Drawbar/Pot End 3.3V+ (Reference)

PL13 Analog Controller B (Lower Manual)
Pin - function
1: Drawbar 16
2: Drawbar 5 1/3
3: Drawbar 8
4: Drawbar 4
5: Drawbar 2 2/3
6: Drawbar 2
7: Drawbar 1 5/9
8: Drawbar 1 1/3
9: Drawbar 1
10: Drawbar Bass 16
11: Drawbar Bass 8
12: Drawbar/Pot Bass Sustain
13, 14: Drawbar/Pot common Ground
15: Drawbar set A/B switch signal (mk3/mk4 boards only; may be tied to pin 16)
16: Drawbar/Pot End 3.3V+ (Reference)

DC swell/volume control is active also on pin 12 of PL9. Even with MIDI control, a swell pedal should be connected to SWELL jack. This overrides MIDI volume control. You may connect a swell pedal like Yamaha FC-7 or a simple volume pot to the SWELL jack. Do not connect pin 12 of PL9 if swell jack used.

HX3 mainboard is set to tone/treble and amp volume control inputs active by factory (may be altered also with HX3 Remote or MenuPanel). Tone pot center is connected to pin 10 of PL9. If digital Leslie emulation is licenced on HX3, pin 11 becomes the Leslie amp volume/drive control (mandatory). Amp volume pot center is connected to pin 11 of PL9. Both pots begin with Gnd and end with Ref 3.3V+.

Please note: Open analog inputs (unconnected) will "float" and change randomly, even with presets active. Tie unused inputs to ground or fixed level (ie. trimpot).

Connecting Digital Inputs

HX3 mk3/mk3 provides 16 digital inputs plus one rotary swich input. Switches are defined as tab stops, rocker or toggle switches, buttons are momentary switch contacts, normally open. All inputs are active low, i.e. tie to ground when switch/button is operated.

Panel 16

Easiest solution for a register/stop panel is using our Panel 16 board connected to PL7 and PL11 by two 10-wire flat ribbon cables. Panel 16 provides 16 buttons for complete HX3 control; just add the rotary switch for vibrato depth.

Panel 16 has 4 "Common Preset" buttons, common to upper and lower manual. They may be used as buttons selecting V1-V3 vibrato or C1-C3 Chorus depth by updating your HX3 to "Button Vibrato" (_btnvib) firmware. In this case, omit the vibrato rotary switch.

Panel 16 PCB may be cut along "CUT HERE" line to get separate sections with 8 buttons each.

Other Buttons or Switches

Instead of Panel 16 you may also connect your own buttons or tab switches (up to 16). Every function is activated by either a button on digital inputs PL7/PL11 or a switch on PL8/PL12 (mk2 only). A momentary contact to ground on each PL7/PL11 pin will toggle it's status and drive indicator LEDs (see schematic). Leave unused digital inputs open.

Newer mk3 and mk4 boards do not provide additional switch inputs. To use tab stop switches on mk3/mk4 boards, define PL7 and PL11 inputs as switches with HX3 Remote Application, "Organ defaults" parameter page. Check boxes in "ButtonMask" parameter row 479 and 480 to define an input pin as a switch instead of a button. The rightmost check box represents Pin 1 and so forth, up to leftmost box for pin 8. When using buttons, an indicator LED should be installed as shown; otherwise there is no indication if a tab stop is on or off.

For mk2 boards, Pin functions of PL8/PL12 are equivalent to PL7/PL11, but provide separate tab stop switch inputs. Strictly use PL7/PL11 as button/LED inputs and PL8/PL12 as switch inputs with same functionality. Parameters 479 and 480 are invalid here.

Vibrato/chorus V1 to C3 is selected by a rotary switch:

Pinout PL5 Vibrato rotary switch
Pin - function (active low – switch to Gnd)
nc: Vib1 (no connection)
1: Cho1
2: Vib2
3: Cho2
4: Vib3
5: Cho3
6: not used
7: not used
8: MEM LED- (optional)
9: MEM LED+ (optional)
10: Common Gnd

Four "Common Preset" inputs (common to upper and lower manual) on PL11 may be used as buttons selecting V1-V3 vibrato or C1-C3 Chorus depth by updating your HX3 to "Button Vibrato" (_btnvib) firmware. In this case, omit the vibrato rotary switch.

Pinout PL7 buttons (momentary contact, optional LED) or PL8 tab/rocker switches on mk2 boards
Pin - function (active low – switch to Gnd)
1: Perc ON, like B3
2: Perc SOFT
3: Perc FAST
4: Perc THIRD
5: Vib ON upper
6: Vib ON lower
7: Leslie ON (connected LED blinks with Leslie speed)
8: Leslie FAST
9: (+5V, used only for button LEDs supply, e.g. on Panel16)
10: Common Gnd

Pinout PL11 buttons (momentary contact, optional LED) or PL12 tab/rocker switches on mk2 boards
Pin - function (active low – switch to Gnd)
1: Common Preset 1 (only button on PL11 - do not use pin 1 of PL12!)
2: Common Preset 2 (only button on PL11 - do not use pin 2 of PL12!)
3: Common Preset 3 (only button on PL11 - do not use pin 3 of PL12!)
4: Common Preset 4 (only button on PL11 - do not use pin 4 of PL12!)
5: EFX 1 / Reverb 1
6: EFX 2 / Reverb 2
7: Bass on Leslie (routes pedal bass also to Leslie simulation if ON)
8: Split ON
9: (+5V, used only for button LEDs supply, e.g. on Panel16)
10: Common Gnd

Connecting Presets

HX3 board does provide 4 "common" presets (see Pinout PL11) for both upper and lower manual. It may be extended to 2x8, 2x12 or 2x16 presets with optional boards Preset 12 (obsolete), Preset 12-2, Preset 16 (one or two) or Preset 24 (obsolete). All connect to HX3 PL4 by 10-wire flat ribbon cable. HX3 PL4 is a I2C bus system, so all boards connect in parallel (use multiple 10-pin plugs on one cable if necessary); Preset12 and Preset16 yield an extension route-through connector for adding more boards. Cable length on HX3 PL4 should not exceed 75 cm (30") in total. Use appropriate firmware for each preset solution. See description of each product for details. Obsolete boards are still supported by newer firmware issues.

Preset 16

Two daisy-chained Preset 16 boards connected to PL4. Optional MenuPanel may be connected to last Preset16 board.

Preset 16 is a self-contained panel with 2 rows of 8 LED buttons each. It connects to HX3 PL4 by a 10-wire flat ribbon cable. A second Preset 16 may be connected to second 10-pin header (daisy-chain). Both 10-pin headers on Preset16 may be used (are wired in parallel). A jumper set on Preset 16 selects upper manual. If jumper is absent, Preset16 works on lower manual.

If only one Preset 16 is connected, jumper JP1 must be set. Now upper row of buttons is for upper manual, lower row for lower manual (i.e. 8 presets each). This preset split function may be overridden by param 484 in HX3 Remote set to ON.

If using 2 sets of drawbars per manual by DB9-MPX drawbar board board, set HX3 Remote "Organ Defaults" parameter 483 "2nd Drawbar Set" to 1. This will activate 1st drawbar set on Preset 0, 2nd drawbar set on Preset 1.

Preset 12-2

Preset 12-2 board connects to HX3 PL4. Flat ribbon cable may be extended with additional connector to accomodate MenuPanel.

Preset 12-2 is an interface board for up to 2 x 12 "inverted" preset keys (with optional LED indicators) as found on Hammond console organs. Preset 16 PCB is similar to Panel 16, but has additional circuitry and connects to HX3 PL4 by a 10-wire flat ribbon cable. See schematics for pin designation. Pin 1 of both 14-pin headers is Preset 0 = Live (right drawbar set) = B key, pin 2 is Preset 1 = Live (left drawbar set) etc. downto pin 12 = CANCEL key.

Standard organ firmware supports momentary contacts. To save a preset, press and hold preset key/button for 2 seconds.

For latching keys (original Hammond keybeds), use "Latching" type firmware. Save a preset by pressing CANCEL key (i.e. Preset 11) and then destination preset key, hold both for 2 seconds and release CANCEL.

If using 2 sets of drawbars per manual by DB9-MPX drawbars/multiplexer and Preset12-2 board, set HX3 Remote "Organ Defaults" parameter 483 "2nd Drawbar Set" to 1.

Pinout PL1 (LEDs)
Pin - function
1: LED 1 cathode (Preset 0, "B" key drawbar set)
2: LED 2 cathode (Preset 1, "A#" key drawbar set)
3: LED 3 cathode (Preset 2)
...
12: LED 12 cathode (Preset 11, CANCEL key)
13,14: Common LED anode (+)

LED outputs have on-board 220 Ohms resistors, resulting in 15 mA LED current. Long leg of LEDs is anode (+), short leg is cathode (-).

Pinout PL2 (Buttons/Switches)
Pin - function (active low – switch to Gnd)
1: Switch 1 (Preset 0, "B" key drawbar set)
2: Switch 2 (Preset 1, "A#" key drawbar set)
3: Switch 3 (Preset 2)
...
12: Switch 12 (Preset 11, CANCEL key)
13,14: Common switch ground (0V)

Note: The old Preset12-MPX boards for HX3 mk2/mk3 may be used as well for HX3 mk4 and mk5. They do not offer a variable preset number for second drawbar set, though. Instead, second drawbar set is hard-wired to Voice Preset 15. So you have to change 2nd drawbar set number in parameter #1496 (HX3.5) resp #496 (HX3.4) to 15, not to 1.

Connecting Keyboard Scan Board(s)

For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Use HX3 Remote application, "Organ Defaults" parameter 477 to set appropriate scan board driver (so called Scan Core) for board used. However, HX3 may be controlled by MIDI key ON/OFF messages from any keyboard by using Scan Core 1 (MIDI input) without any scan board connected.

Scan Cores will support MIDI input/output too, but for MIDI remote we recommend MIDI input driver as this one has the most versatile transposing and octave shifting features, supporting the full range of 88 key manuals.

FatarScan2

FatarScan2 connection diagram

A single FatarScan2 board is connected to HX3 PL14. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page Anschluss der Scan-Platine FatarScan2 (german) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).

Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to HX3 PL15 (!). FatarScan2 board is are activated by HX3 Remote application, "Organ Defaults" parameter 477.

Bass25

Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply

Bass25 scan board (refer to PDFs in our Github repo folder PLATNEN/BASS25) may be used as an addition to FatarScan2, OrganScan61, Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). Board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:

Old version (beige PCB):

  • JP6 inserted always
  • JP7 2-3 inserted if OrganScan61 (daisy chain on HX3 PL14), Bass25 to last OrganScan61 board
  • JP7 1-2 inserted if FatarScan2 on HX3 PL14, or Scan16 Strip and Bass25 to HX3 PL15
  • JP8 2-3 inserted always

Contacts always switch to ground (busbar).

New version MIDISCAN25 (green PCB):

  • JP1 solder bridge, always open
  • JP2 solder bridge if used with OrganScan61 (daisy chain on HX3 PL14), Bass25 to last OrganScan61 board
  • JP3 solder bridge if used with FatarScan2 on HX3 PL14 or Scan16 Strip on HX3 PL15

Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:

Pin - function (active low – switch to Gnd)
1: Lowest note "C"
...
25: Highest note "C"
26: Common ground (busbar)

JP3 and JP4 solder bridges must be closed. 2-pin inline header PL9 also provides common ground for the busbar.

Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.

Bass25 MIDI

Bass25 MIDI is equipped with an own MIDI controller and MIDI output jack. It is connected to HX3 mk3/mk4 main board by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.

Pin - function (active low – switch to Gnd)
1: Lowest note "C"
...
25: Highest note "C"
26: Common ground (busbar)

JP3 solder bridge must be closed.

JP4 solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted (mk3 and mk4 boards only).

For separate power supply (internal +5V or external 9V DC wall wart), open JP4 solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground (refer to PDF schematics in our Github repo folder PLATNEN/BASS25).

A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two additional jumpers on HX3 PL10 pins 7-8 and 9-10. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.

Scan16-Strip Set

Connection of Scan16 to HX3 board.

As an alternative to old OrganScan61 one or two sets of tall Scan16-Strip boards (one set for each manual) may be used which yield easier installation on some keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to schematics and part placement in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to HX3 PL15. Bass25 may be used as pedal scan board. A jumper on "lowest" Scan16 board determines if keybed is upper, lower or bass pedal:

JP1 = Upper manual
JP2 = Lower manual
JP3 = Pedal notes

Please note: lowest key contact pad on Scan16 is always "C" key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with "F" key. On 49-key manuals, connect pad PL20 to highest "C" note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.

Scan16 boards for one or two 49/61-key manuals is are activated by HX3 Remote application, "Organ Defaults" parameter 477.

Scan61-Inline

Scan61-Inline Board connected to HX3 mk4

Scan61-Inline works exactliy like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to schematics and part placement in out Git repo. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to HX3 PL15. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:

JP1 = Upper manual
JP2 = Lower manual
JP3 = Pedal notes

Please note: lowest key contact pad on Strip61-Inline is always "C" key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.

Scan61-Inline boards are activated by HX3 Remote application, "Organ Defaults" parameter 477, set to Scan16/61.

OrganScan61 Board Set

Obsolete, for reference only!

Connection diagram of OrganScan61 (click picture to enlarge)

A set of up to 3 "daisy-chained" OrganScan61 boards are connected to PL14 if HOAX was ordered with OrganScan61 firmware driver. Refer to picture. Be shure not to twist connectors (red marked ribbon lead must match with pin 1 of all ribbon cable connectors, indicated by a triangle marking). Total cable length should not exceed 1,5m. First board in row is upper manual, second is lower manual and third (rightmost in picture) is bass pedal (not completely populated since only 25 keys are present). Bass25 board may be used as an alternative to last OrganScan61 board; it has the same functionality (but different key connectors). See page Anschluss der Scan-Platine OrganScan61 (KlangComputer) (german) for more pictures.

Inputs are active low (switch to ground), so connecting them to Gnd pins 13 to 16 of PL33 (PL31 on bass) on OrganScan61 board should yield the appropriate note. See OrganScan61 schematic for connector pinout.

Keybed Connection
Plug/Pin - function (active low – switch to Gnd)
PL30/1: Note 1 = lowest C 1
PL30/16: Note 16 = D# 2

PL31/1: Note 17 = E 2
PL31/16: Note 32 = G 3

PL32/1: Note 33 = G# 3
PL32/16: Note 48 = H 4

PL33/1: Note 49 = C 5
PL33/16: Note 61 = C 6
PL33/14,15,16: Gnd/Busbar

Pedals Connection
(or use Bass25 scan board)

Plug/Pin - function (active low – switch to Gnd)
PL30/1: Note 1 = lowest C 1
PL30/16: Note 16 = D# 2

PL31/1: Note 17 = E 2
PL31/9: Note 25 = C 2
PL31/14,15,16: = Gnd/Busbar

OrganScan61 boards are activated by HX3 Remote application, "Organ Defaults" parameter 477.

Firmware Settings

Firmware type depends on preset board used and number of manuals. Factory default is Preset16/Preset12-2 standard organ firmware, two keybeds with drawbar set for each manual. Update your HX3 with HX3 Remote Application to different firmware if using a single drawbar set (no lower manual), latching preset keys or Preset24. Even with correct firmware installed, there are some settings that have to be done with HX3 Remote. All parameters can be found in HX3 Remote's Organ defaults tab:

Parameter - Function
438/439 - Output Jack Configuration Routes 5 different signals to 2 (or 4 with extension board) audio output jacks (32 variants).
477 - Scan Core Set to scan board used in yout organ or to sole MIDI input.
478 - No Analog Inputs Set to ON (255) if no pots or drawbars connected. Drawbars are controlled by MIDI only.
479 - ButtonMask Pins PL7 Check boxes for each PL7 pin that is connected to a switch instead of a button (applies to mk3 and mk4 boards).
480 - ButtonMask Pins PL11 Check boxes for each PL11 pin that is connected to a switch instead of a button (applies to mk3 and mk4 boards).
481 - AMP Pot Enable When OFF, HX3 simulated rotary tube amp volume is controlled by MIDI or MenuPanel only. Set to ON (255) if simulated rotary amp is controlled by potentiometer on pin PL9 pin 11.
492 - AUX Pot Routing When OFF, HX3's TONE and MASTER VOLUME functions are controlled by MIDI or MenuPanel only. Set to 1 to route Aux analog input (PL9 pin 10) to TONE function. Set to 2 to route input to MASTER VOLUME function (firmware 3.925 and up).
483 - 2nd DBs Preset Number Default 16 (no second drawbar set per manual). Set to 1 if using Preset 16 or Preset 12-2 and two drawbar sets per manual with drawbar boards Drawbar 9/12 plus Drawbar 9-MPX. Set to 15 if using old Preset 24 or Preset 12 MPX boards.

Options

MenuPanel

HX3 MenuPanel, fitted with optional LEDs

Our MenuPanel allows convenient adjustments of various HX3 parameters to tweak your setup. Two versions available, short one without indicator LEDs intended for organ installation.

Connect HX3 MenuPanel to HX3 PL4 using a 10-wire flat ribbon cable. HX3 firmware from version 3.41 and up will recognize the MenuPanel and act accordingly. HX3 MenuPanel may be used in parallel/simultaneously with Preset12-2, Preset16 and Preset24 boards connected to HX3 PL4.

Extend a flat ribbon with additional connector to your cable on HX3 PL4 or use unoccupied 10-pin header on (last) Preset16 board which also carries the PL4 signal. PL4 carries an I2C bus system where all devices are wired in parallel.

See page HX3 MenuPanel for usage instructions.

Serial USB cable

FTDI cable connected to HX3

HX3 board is configured and updated by serial connection through FTD USB adaptor cable or USB interface. See page HX3 Remote Application for details.

HX3 Extension Board

The HX3 extension board for mk3/mk4 mainboards adds two additional audio outputs, Leslie(R) control and preamplifier for 9- and 11-pin Leslies, headphone jack, USB interface for parameter control to your HX3 mainboard. It also adds a MIDI OUT in case HX3 mk3 board is jumpered for two MIDI inputs. See HX3 Extension Board Installation for details.

If the Extension board is installed, both MIDI jacks on mainboard should be jumpered as MIDI INs as the Extension board has its own MIDI OUT.