This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”


===Schweller-Einstellungen in HX3 speichern===
===Saving swell settings in HX3===


Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter ''Volume Pots'' zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.


Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit "Store to Organ" auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab "Organs" und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.


==EFX-Eingang nutzen==
==EFX-Eingang nutzen==

Version vom 11. Dezember 2025, 16:10 Uhr

Sweep Generator Tab of HX3 Manager 7.21

Preface

Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a sine wave test generator is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image.

Attention: After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.

Loading Measurements and Reference Curvesn

Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.

Saving of Measurements

Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).

Creating a new Measurement

For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”

A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.

Sweeps

Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable.

A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also #Setting up a license.

Measuring the frequency response of the preamp simulation

Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.

Single Sweep

Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).

Auto Sweep

This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”

Saving swell settings in HX3

Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.

Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.

EFX-Eingang nutzen

Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen

Unter Verwendung des Effektschleifen-Eingangs "EFX Input" (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox "Measure External FX Loop" aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei abgeschaltet, der Frequenzgang ist somit vollkommen linear.

Externe Geräte messen

Zum Test verbinden Sie den Ausgang "Organ" über ein Klinkenkabel direkt mit "EFX Input" und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen.

Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen "Organ" und "EFX Input" eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an "Organ" wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an einem der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.

HX3-Equalizer messen

Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.

Verbinden Sie den Ausgang "Organ" über ein Klinkenkabel direkt mit "EFX Input" und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf "Off" und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.

Lizenz einrichten

Eingabe der Sweep- und Tapering-Lizenz

Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (unbedingt Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.

Klicken Sie nach dem Connect mit Ihrem Gerät im HX3-Manager-Startfenster auf Manager Licence. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als "Customer Name" ggf. Ihr Name erscheinen. Tragen Sie nun "Customer Name" und "Sweep Generator Licence Key" genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf Activate. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit OK.

Die Lizenzdaten sind in der Datei HX3_userinfo.txt im Verzeichnis editor_files abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in editor_files) kopiert werden, um die Lizenz für das Update zu übernehmen.

Sweep Analyzer

Sweep Analyzer als eigenständiges Programm

Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation HX3_SweepAnalyzer.exe auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der HX3 Manager nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die user- und editor_files-Verzeichnisse.