	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7079</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7079"/>
		<updated>2026-06-05T11:32:52Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar-Tastatur mit rotem MicroMatch-Steckverbinder]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
==OrganScan61==&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7078</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7078"/>
		<updated>2026-06-05T11:31:35Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* PulseScan61 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with red MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
(Not recommended for new desgns)&lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 keybed equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN box header on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7077</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7077"/>
		<updated>2026-06-05T11:31:09Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with red MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
(Not recommended for new desgns)&lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN box header on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7076</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7076"/>
		<updated>2026-06-05T11:30:47Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar-Tastatur mit rotem MicroMatch-Steckverbinder]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
Für das FatarScan2-Board verwenden Sie den Scan-Treiber &#039;&#039;scanfatr.dat&#039;&#039;, zu installieren mit dem HX3 Manager/Updater oder Bootloader.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
==OrganScan61==&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7075</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7075"/>
		<updated>2026-06-05T11:29:21Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan1-61 und FatarScan1-73 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
(Not recommended for new desgns)&lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN box header on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7074</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7074"/>
		<updated>2026-06-05T11:29:06Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* PulseScan61 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
(Not recommended for new desgns)&lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN box header on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7073</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7073"/>
		<updated>2026-06-05T11:28:24Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
(Not recommended for new desgns)&lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN input on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7072</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7072"/>
		<updated>2026-06-05T11:27:33Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* PulseScan61 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 equipped with scan board]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
We supply the low-cost &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; keyboard with the scan board already fitted. The SCAN OUT connector is connected to the FATAR SCAN input on the HX3 motherboard via a 10-pin ribbon cable. Any lower manual present is connected via SCAN OUT to the FROM LWR OUT connector on the upper manual; otherwise, the FROM LWR OUT connector remains open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the circuit board has been connected, install the scan driver &#039;&#039;scanpl61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanpl61.dat&#039;&#039; has been installed, the Pulse Keyboard Board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
The Pulse keyboard is also compatible with our MIDI Scan controller (https://github.com/keyboardpartner/MIDI-Scancontroller).&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 mounted on Fatar TP8/O keybed]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
FatarScan1 boards will replace the older FatarScan2 boards in future. They significantly simplify installation and wiring and are screwed directly beneath the keyboard (see image), using the existing drill holes. Unlike the FatarScan2, a separate board is required for each manual. Two 16mm-long screws and spacer sleeves for mounting are included with the product.&lt;br /&gt;
&lt;br /&gt;
Connect the supplied 16-pin Micromatch cables to the FatarScan1 board as shown. The 10-pin ribbon cable connects SCAN OUT to the FATAR SCAN input on the HX3 motherboard. If a lower manual is present, connect it via SCAN OUT to the FROM LOWER OUT connector on the upper manual; otherwise, leave the FROM LOWER OUT connector open. The total length of both cables should not exceed 1 m.&lt;br /&gt;
&lt;br /&gt;
Once the board has been connected, install the scan driver &#039;&#039;scanft61.dat&#039;&#039; via the HX3 Manager. You may need to restart the system after installation so that the firmware recognises the new driver. Please note that once &#039;&#039;scanft61.dat&#039;&#039; has been installed, the FatarScan1 board must also be connected; otherwise, communication with the HX3 Manager will not be possible.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7071</id>
		<title>Scan Boards</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards&amp;diff=7071"/>
		<updated>2026-06-05T11:22:13Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|Scan board connection diagram - old mk4 board shown, disregard PL indices. 4014 SCAN boards are to be wired in parallel (bus), only one cable needed with route-through]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
For lowest key-to-audio latency we recommend direct keyboard connection via scan board (different versions available). Scan boards are activated by update from SD card (appropriate for your application) or &#039;&#039;HX3 Manager&#039;&#039;. Upload driver &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; resp. &#039;&#039;scansr61.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; window. All Scan drivers will support MIDI input/output too, but for pure MIDI remote we recommend MIDI input driver &#039;&#039;scanmidi.dat&#039;&#039;. New HX3 boards come with &#039;&#039;scanmidi.dat&#039;&#039; pre-installed.&lt;br /&gt;
&lt;br /&gt;
Specific scan boards are available for keybeds, depending on contact type (Fatar matrix or single contacts). Bass pedals may be connected to an additional Scan16-Strip, Scan61-Inline or Bass25 board wired to &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; box header (!).&lt;br /&gt;
&lt;br /&gt;
For schematics please refer to our [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 &#039;&#039;&#039;schematics repository&#039;&#039;&#039;] on our update server.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 connection to HX3.7 board]]&#039;&#039;&#039;&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Sf2_mm16.jpg|300px|thumb|right|Fatar keybed with MicroMatch connector]]&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
A single [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2 board] is connected to &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; box header. One or two Fatar 61 key manuals (type TP/8O or similar) may be connected to one FatarScan2 board using a special cable set (MicroMatch connectors to keyboard scanning strips). See page [[Anschluss der Scan-Platine FatarScan2]] (German language) for more pictures. We recommend buying the FatarScan2 cable set for connection to MicroMatch headers on Fatar keybeds (one set for each manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2 boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scanfatr.dat&#039;&#039; to HX3 using &#039;&#039;Updater&#039;&#039; or &#039;&#039;BootLoad&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Please note:&#039;&#039;&#039; The FatarScan2 board must be connected when using the scanfatr.dat driver, otherwise communication with the HX3 Manager will be blocked.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Connection of Scan16 Strip or Scan61 to HX3 board (HX3.4 pictured. Note: HX3.6 has different PL designators)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
For most &amp;quot;one contact per key&amp;quot; organs one or two sets of tall [https://shop.keyboardpartner.de/en/p/scan16-strip Scan16-Strip] boards (one set for each manual) may be used which yield easier installation on these keybeds. For each manual you need 3 (44 or 49 keys) or 4 (61 keys) Scan16 boards. Please refer to [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN schematics and part placement] in out Git repo. All Scan16 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12 4014 SCAN&#039;&#039;&#039;. Bass25 may be used as pedal scan board. A jumper on &amp;quot;lowest&amp;quot; Scan16 board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Scan16 is always &amp;quot;C&amp;quot; key on 4- and 5-octave keybeds. On 61-key manuals, upper part of rightmost Scan16 board may be cut off as marked on PCB silk screen printing (or pads are left open). On 44-key manuals, lowest 5 pads are left open, manual(s) start with &amp;quot;F&amp;quot; key. On 49-key manuals, connect pad PL20 to highest &amp;quot;C&amp;quot; note. All contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan16 boards for one or two 49/61-key manuals is are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window. See page [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] (german only) for pictures.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board connected to HX3 board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/scan61-inline Scan61-Inline] works exactly like a Scan16-Strip set of 4 PCB, but has all parts mounted on one compact PCB (one Scan61-Inline needed for each manual). So each key must be wired separately. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in out schematics repository. All Scan61 equipped manuals are wired in parallel with one 10-wire flat ribbon cable (multiple connectors attached) to &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;. Bass25 may be used as a third pedal scan board. A jumper on Scan61-inline board determines if keybed is upper, lower or bass pedal:&lt;br /&gt;
&lt;br /&gt;
JP1 = Upper manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Lower manual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal notes&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Please note: lowest key contact pad on Strip61-Inline is always &amp;quot;C&amp;quot; key. On shorter manuals, leave unused key inputs open. As on OrganScan61 or Scan16-Strip, all contacts must switch to ground. Boards provide ground lugs for connection to busbar.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline boards are activated by update from SD card or &#039;&#039;HX3 Manager&#039;&#039; application. Upload driver &#039;&#039;scansr61.dat&#039;&#039; to HX3.6 using &#039;&#039;Updater&#039;&#039; window.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 and Bass25 MIDI (top right) with own MIDI OUT and phantom supply&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
The [https://shop.keyboardpartner.de/en/p/bass25 Bass25] scan board (refer to PDFs in [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our schematics repository) may be used as an addition to FatarScan2,  Scan61-Inline and Scan16-Strip boards for convenient connection of bass pedal contacts as pictured above (note different HX3 headers). The board may be placed in bottom of organ if 10-wire flat ribbon cable to HX3 or last OrganScan61 board does not exceed 1m. Please note jumper setting on Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; solder bridge, always open&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; solder bridge if used with HX3.4 OrganScan61 (not supported on HX3.6)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge if used with FatarScan2 on &#039;&#039;&#039;HX3.6 PL8&#039;&#039;&#039; or Scan16 Strip on &#039;&#039;&#039;HX3.6 PL12&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 or to the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 and JP4&#039;&#039;&#039; solder bridges must be closed. &lt;br /&gt;
&lt;br /&gt;
Note: A third Scan16-Strip or Scan61-Inline board may alternatively be used for bass pedal instead of Bass25, using only the first 13 or 25 contact inputs. Set jumper JP3 on scan boards to enable them for bass pedal use.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[https://shop.keyboardpartner.de/en/p/bass25-midi Bass25 MIDI] is equipped with an own MIDI controller and MIDI output jack. It is connected to the HX3.6 mainboard by 5-wire MIDI cable. Bass25 MIDI provides in-line headers and a 26-pin flat ribbon cable connector for alternative connection of bass pedal contacts. 2-pin inline header PL9 also provides common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI key connection&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Function&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Lowest Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|further keys&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Highest Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Common ground (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Instead of PL1, the keyboard contacts can also be connected to the inline pin headers PL2 to PL7 on the solder pads in front of the pin headers (left pin PL2: lowest C). The 2-pin inline header PL9 also serves as common ground for the busbar.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; solder bridge must be closed. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge must be closed if Bass25 MIDI is powered by phantom supply from HX3 board, left MIDI input jack (seen from back). MIDI phantom power jumpers on HX3 board must be inserted. &lt;br /&gt;
&lt;br /&gt;
For separate power supply (internal +5V or external 9V DC wall wart), open &#039;&#039;&#039;JP4&#039;&#039;&#039; solder bridge. Use 2-pin header PL12 next to MIDI OUT jack to supply internal +5V: Pin 1 (left, facing towards diode) is VCC +5V, pin 2 (right) is ground. Please refer to [http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 schematics and part placement] in our repository.&lt;br /&gt;
&lt;br /&gt;
A +5V MIDI phantom supply on outer pins of MIDI input may be obtained from HX3 mainboard by inserting two &#039;&#039;&#039;additional&#039;&#039;&#039; jumpers on HX3.6 PL20 &#039;&#039;&#039;pins 7-8 and 9-10&#039;&#039;&#039;. Do not install these jumpers if connecting other MIDI gear not using a phantom supply.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Switches===&lt;br /&gt;
&lt;br /&gt;
The &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; connector (PL16 for HX3.5, PL21 for HX3.7) controls Sustain/Sostenuto and MIDI Cancel for each manual (Fatar and Scan61 drivers only). With the MIDI scan driver and HX3.7 this is the output for 7 status LEDs of the MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Foot)switches must connect the relevant input to ground to activate the function:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd for switches&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Please note: These inputs are unprotected and &#039;&#039;&#039;can be destroyed by static charging, e.g. by plugging in a cable&#039;&#039;&#039;. Each AUXILIARY input used as a foot switch should be protected by a Zener diode 4V7/250mW (anode to Gnd, cathode ring to input).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7070</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7070"/>
		<updated>2026-06-05T11:21:17Z</updated>

		<summary type="html">&lt;p&gt;Bovist: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
==FatarScan2==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
Für das FatarScan2-Board verwenden Sie den Scan-Treiber &#039;&#039;scanfatr.dat&#039;&#039;, zu installieren mit dem HX3 Manager/Updater oder Bootloader.&lt;br /&gt;
&lt;br /&gt;
==PulseScan61==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
==FatarScan1-61 und FatarScan1-73==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
==Scan16-Strip Set==&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
==Scan61-Inline==&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
==OrganScan61==&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
==Bass25==&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
==Bass25 MIDI==&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7069</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7069"/>
		<updated>2026-06-05T10:45:20Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
Für das FatarScan2-Board verwenden Sie den Scan-Treiber &#039;&#039;scanfatr.dat&#039;&#039;, zu installieren mit dem HX3 Manager/Updater oder Bootloader.&lt;br /&gt;
&lt;br /&gt;
===PulseScan61===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7068</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7068"/>
		<updated>2026-06-03T10:08:34Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* PulseScan61 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===PulseScan61===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur vom Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; liefern wir mit bereits montiertem Scan-Board. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
Das Pulse-Tastatur ist auch für unseren MIDI-Scan-Contoller (https://github.com/keyboardpartner/MIDI-Scancontroller) geeignet.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7067</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7067"/>
		<updated>2026-06-03T08:42:59Z</updated>

		<summary type="html">&lt;p&gt;Bovist: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===PulseScan61===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:Pulsescan61.JPG|300px|thumb|right|Pulse 6105 mit Scan-Platine]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur von Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; wird von uns mit bereits montiertem Scan-Board geliefert. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanpl61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanpl61.dat&#039;&#039; auch das Pulse-Keyboard-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Datei:Pulsescan61.JPG&amp;diff=7066</id>
		<title>Datei:Pulsescan61.JPG</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Datei:Pulsescan61.JPG&amp;diff=7066"/>
		<updated>2026-06-03T08:38:53Z</updated>

		<summary type="html">&lt;p&gt;Bovist: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7065</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7065"/>
		<updated>2026-06-03T08:37:57Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* PukseScan-61 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===PulseScan61===&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur von Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; wird von uns mit bereits montiertem Scan-Board geliefert. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7064</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7064"/>
		<updated>2026-06-03T08:37:38Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan1-61 und FatarScan1-73 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===PukseScan-61===&lt;br /&gt;
&lt;br /&gt;
Die preiswerte Tastatur von Typ &#039;&#039;&#039;Pulse 6105&#039;&#039;&#039; wird von uns mit bereits montiertem Scan-Board geliefert. Der Steckverbinder SCAN OUT wird über ein 10poliges Flachbandkabel mit dem Eingang FATAR SCAN des HX3-Mainboards verbunden. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LWR OUT des Obermanuals angeschlossen; der Steckverbinder FROM LWR OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber &#039;&#039;scanft61.dat&#039;&#039; über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des &#039;&#039;scanft61.dat&#039;&#039; auch das FatarScan1-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7063</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7063"/>
		<updated>2026-06-03T08:27:52Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan1-61 und FatarScan1-73 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan1 an TP8/O Tastatur]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt (siehe Bild), unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Zwei 16mm lange Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie die beiligenden 16poligen Micromatch-Kabel wie abgebildet mit der FatarScan1-Platine. Das 10polige Flachbandkabel verbindet SCAN OUT mit dem Eingang FATAR SCAN des HX3-Mainboards. Ein eventuell vorhandenes Untermanual wird mit SCAN OUT an den Steckverbinder FROM LOWER OUT des Obermanuals angeschlossen; der Steckverbinder FROM LOWER OUT bleibt ansonsten offen. Die Gesamtlänge beider Kabel sollte 1m nicht überschreiten.&lt;br /&gt;
&lt;br /&gt;
Nach dem Anschluss der Platine installieren Sie den Scan-Treiber *scanft61.dat* über den HX3-Manager. Eventuell ist nach Installation ein Neustart erforderlich, damit die Firmware den neuen Treiber erkennt. Beachten Sie, dass nach Installation des *scanft61.dat* auch das Scan-Board angeschlossen sein muss, ansonsten ist keine Kommunikation mit dem HX3 Manager möglich.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7062</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7062"/>
		<updated>2026-06-03T08:06:50Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan1-61 und FatarScan1-73 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:fatarscan1.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt, unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Drei Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Datei:Fatarscan1.JPG&amp;diff=7061</id>
		<title>Datei:Fatarscan1.JPG</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Datei:Fatarscan1.JPG&amp;diff=7061"/>
		<updated>2026-06-03T08:05:08Z</updated>

		<summary type="html">&lt;p&gt;Bovist: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7060</id>
		<title>Scan Boards (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Scan_Boards_(deutsch)&amp;diff=7060"/>
		<updated>2026-06-03T08:04:24Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* FatarScan2 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;[[Datei:Wiring fatar.png|300px|thumb|right|FatarScan2-Anschlussplan (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;  &lt;br /&gt;
&lt;br /&gt;
Für geringste Key-to-Audio-Latenz empfehlen wir den direkten Tastaturanschluss über Scan-Boards (verschiedene Versionen verfügbar). Scan-Boards werden durch Update von SD-Karte (passend zu Ihrer Anwendung) oder &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie die Treiber &#039;&#039;scanmidi.dat&#039;&#039;, &#039;&#039;scanfatr.dat&#039;&#039; bzw. &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Alle Scan-Treiber unterstützen auch MIDI-Input/Output, aber für reine MIDI-Fernsteuerung empfehlen wir den MIDI-Input-Treiber &#039;&#039;scanmidi.dat&#039;&#039;. Neue HX3-Mainboards werden mit installierter &#039;&#039;scanmidi.dat&#039;&#039; geliefert.&lt;br /&gt;
&lt;br /&gt;
===FatarScan2===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:FatarScan2b.JPG|300px|thumb|right|FatarScan2 Anschluss an HX3.7]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Eine einzelne [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/fatarscan2 FatarScan2-Karte] wird am Wannenstecker &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. An eine FatarScan2-Platine können ein oder zwei Fatar 61-Tastaturen (Typ TP/8O o.ä.) mit Hilfe eines speziellen Kabelsatzes (MicroMatch-Stecker zu Tastatur-Scanleisten) angeschlossen werden. Wir empfehlen den Kauf des FatarScan2-Kabelsatzes für den Anschluss an die MicroMatch-Steckerleisten der Fatar-Tastaturen (ein Satz für jedes Manual).&lt;br /&gt;
&lt;br /&gt;
FatarScan2-Karten werden durch Update von SD-Karte oder &#039;&#039;HX3 Manager&#039;&#039; Anwendung aktiviert. Laden Sie den Treiber &#039;&#039;scanfatr.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3 (ab Version 3.5). Sobald der Fatar-Scantreiber aktiv ist, muss auch eine FatarScan2-Platine an &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen sein, ansonsten kann es zu lauten Störgeräuschen oder zum Einfrieren des HX3 kommen.  Siehe Seite [[Anschluss der Scan-Platine FatarScan2]] für weitere Bilder.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;FatarScan2 PL5&#039;&#039;&#039; wird über ein max. 1m langes, 10poliges Flachbandkabel an HX3-Steckverbinder &#039;&#039;&#039;FATAR SCAN&#039;&#039;&#039; angeschlossen. Bitte bei der Anfertigung des Flachbandkabels mit handelsüblichen Pfostenverbindern auf die Polarität achten: Pin 1 (durch eingeprägtes Dreieck am Stecker und an der Buchse gekennzeichnet) = rote Kabelader.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Die 61er Fatar-Tastaturen besitzen zwei Segmente. Die Verbindung zu den zwei Tastatur-Hälften &#039;&#039;Upper 29 Keys&#039;&#039; (obere 29 Noten) und &#039;&#039;Lower 32 Keys&#039;&#039; (untere 32 Noten) für jedes Fatar-Manual erfolgt mit je zwei 16poligen Flachbandkabeln. Auf FatarScan2-Seite werden 16polige Pfostenverbinder montiert, auf Tastaturseite 16polige MicroMatch-Stecker (Pin 1 = rotes Kabel auf die Seite mit der längeren Rastnase, siehe Bild). Die 16poligen Kabel zu den Tastaturen sollten nicht länger als 50cm sein. Bei Selbstanfertigung der Kabel können die 16pol. MicroMatch-Stecker in einem kleinen Schraubstock angepresst werden; hier sehr sorgfältig vorgehen!&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschluss der Tastatur an FatarScan2:&amp;lt;br&amp;gt;&#039;&#039;&#039;&lt;br /&gt;
PL1 = Obere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL2 = Untere Hälfte Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PL3 = Obere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
PL4 = Untere Hälfte Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Basspedale können an eine zusätzliche Scan16-Strip-, Scan61-Inline- oder Bass25-Karte (siehe unten) angeschlossen werden, die mit &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; (!) verbunden wird.&lt;br /&gt;
&lt;br /&gt;
===FatarScan1-61 und FatarScan1-73===&lt;br /&gt;
&lt;br /&gt;
FatarScan1-Boards ersetzen zukünftig die älteren FatarScan2-Boards. Sie vereinfachen Montage und Verdrahtung erheblich und werden direkt unter der Tastatur verschraubt, unter Verwendung bestehender Bohrlöcher. Im Unterschied zu FatarScan2 ist für jedes Manual eine eigene Platine erforderlich. Drei Schrauben und Abstandshülsen zur Befestigung liegen dem Produkt bei.&lt;br /&gt;
&lt;br /&gt;
===Scan16-Strip Set===&lt;br /&gt;
&#039;&#039;&#039;[[Datei:wiring_scan16.png|300px|thumb|right|Anschluss von Scan16 Strip oder Scan61 an HX3-Platine (HX3.4 abgebildet, PL-Indizes bei neueren ignorieren!)]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Für die meisten &amp;quot;ein Kontakt pro Taste&amp;quot;-Orgeln können ein oder zwei Sätze von langen [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan16/SubProducts/os16-set4 Scan16-Strip] Boards (ein Satz für jedes Manual) verwendet werden, die eine einfachere Installation an diesen Tastaturen ermöglichen. Für jedes Manual benötigen Sie 3 (44 oder 49 Tasten) oder 4 (61 Tasten) Scan16-Platinen. Bitte beachten Sie die [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltpläne und Teileplatzierung] in unserem Git Repo. Alle mit Scan16 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als Pedal-Scanboard verwendet werden. Ein Jumper auf der &amp;quot;untersten&amp;quot; Scan16-Platine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Das unterste Tastenkontakt-Pad auf dem Scan16 ist immer die Taste &amp;quot;C&amp;quot; auf 4- und 5-Oktaven-Tastaturen. Bei 61-Tasten-Manualen kann der obere Teil der rechten Scan16-Platine abgeschnitten sein, wie auf dem Siebdruck der Platine markiert (oder die Pads bleiben offen). Bei 44-Tasten-Manualen bleiben die untersten 5 Pads offen, Manual(e) beginnen mit Taste &amp;quot;F&amp;quot;. Bei 49-Tasten-Manualen wird das Pad PL20 mit der höchsten &amp;quot;C&amp;quot;-Note verbunden. Alle Kontakte müssen auf Masse schalten. Die Boards stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan16-Karten für ein oder zwei 49/61-Tasten-Manuale werden durch Update von SD-Karte oder Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; mit dem &#039;&#039;Updater&#039;&#039;-Fenster auf den HX3.5 hoch. Siehe Seite [[Anschluss_der_Scan-Platine_Scan4014-16_(je_16_Tasten)]] für Bilder.&lt;br /&gt;
&lt;br /&gt;
===Scan61-Inline===&lt;br /&gt;
[[Datei:Scan61-Inline_ansch.JPG|300px|thumb|right|&#039;&#039;&#039;Scan61-Inline Board verbunden mit HX3 Board&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/scan61-inline Scan61-Inline] funktioniert genau wie ein Scan16-Strip-Set mit 4 Platinen, hat aber alle Teile auf einer kompakten Platine montiert (für jedes Manual wird eine Scan61-Inline benötigt). Daher muss jede Taste separat verdrahtet werden. Bitte beachten Sie [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN Schaltplan und Teileplatzierung] in unserem Git Repo. Alle mit Scan61 bestückten Manuale werden parallel mit einem 10-adrigen Flachbandkabel (mit mehreren Steckern) an &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039; verdrahtet. Bass25 kann als drittes Pedal-Scanboard verwendet werden. Ein Jumper auf der Scan61-Inlineplatine legt fest, ob das Tastenfeld oberes, unteres oder Bass-Pedal ist:&lt;br /&gt;
&lt;br /&gt;
JP1 = Obermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP2 = Untermanual&amp;lt;br&amp;gt;&lt;br /&gt;
JP3 = Pedal&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Unterstes Tastenkontakt-Pad bei Strip61-Inline ist immer Taste &amp;quot;C&amp;quot;. Bei kürzeren Manualen lassen Sie unbenutzte Tasteneingänge offen. Wie bei OrganScan61 oder Scan16-Strip müssen alle Kontakte auf Masse schalten. Die Karten stellen Massekontakte für den Anschluss an die Stromschiene zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Scan61-Inline-Karten werden per Update von der SD-Karte oder der Anwendung &#039;&#039;HX3 Manager&#039;&#039; aktiviert. Laden Sie den Treiber &#039;&#039;scansr61.dat&#039;&#039; über das Fenster &#039;&#039;Updater&#039;&#039; auf den HX3.5.&lt;br /&gt;
&lt;br /&gt;
===OrganScan61===&lt;br /&gt;
&lt;br /&gt;
Ein spezieller Scan-Treiber (scanos61.dat) für die &#039;&#039;&#039;veraltete OrganScan61&#039;&#039;&#039; (verwendet bei HX3.4-Installationen) wird mitgeliefert, muss aber manuell mit &#039;&#039;HX3 Manager/Updater&#039;&#039; installiert werden. Schließen Sie die erste OrganScan61-Karte in der Kette an &#039;&#039;&#039;4014 SCAN&#039;&#039;&#039; an. OrganScan61-Karten &#039;&#039;&#039;dürfen nicht&#039;&#039;&#039; mit Bass25-, Scan61- oder Strip16-Karten kombiniert werden, nur mit Bass25 MIDI. Siehe [[HX3_Board_Installation#OrganScan61_Board_Set]] für Details zu OrganScan61.&lt;br /&gt;
&lt;br /&gt;
===Bass25===&lt;br /&gt;
[[Datei:Midibass25.JPG|300px|thumb|right|&#039;&#039;&#039;Bass25 und Bass25 MIDI (oben rechts) mit eigenem MIDI OUT und Phantomspeisung&#039;&#039;&#039;]] &lt;br /&gt;
&lt;br /&gt;
Die [http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25 Bass25] Scanplatine (siehe PDFs in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github Repo-Ordner PLATINEN/BASS25]) kann als Ergänzung zu den FatarScan2, Scan61-Inline und Scan16-Strip Platinen zum bequemen Anschluss der Basspedalkontakte wie oben abgebildet verwendet werden (beachten Sie die unterschiedlichen HX3 Stecker). Die Karte kann im Boden der Orgel platziert werden, wenn das 10-adrige Flachbandkabel zum HX3 oder zur letzten OrganScan61-Karte nicht länger als 1 m ist. Bitte beachten Sie die Jumperstellung am Bass25:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;JP1&#039;&#039;&#039; Lötbrücke, immer offen&lt;br /&gt;
* &#039;&#039;&#039;JP2&#039;&#039;&#039; Lötbrücke bei Verwendung mit HX3.4 OrganScan61 (wird bei HX3.5 nicht unterstützt)&lt;br /&gt;
* &#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke bei Verwendung mit FatarScan2 auf &#039;&#039;&#039;HX3.5 PL9&#039;&#039;&#039; oder Scan16 Strip auf &#039;&#039;&#039;HX3.5 PL13&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Bass25 bietet In-Line-Stecker und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 oder an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3 und JP4&#039;&#039;&#039; Lötbrücken müssen geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
Hinweis: Eine dritte Scan16-Strip- oder Scan61-Inline-Platine kann alternativ für das Basspedal anstelle von Bass25 verwendet werden, wobei nur die ersten 13 oder 25 Kontakteingänge genutzt werden. Setzen Sie den Jumper JP3 auf der Scan-Karte, um sie für die Verwendung als Basspedal zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
===Bass25 MIDI===&lt;br /&gt;
&lt;br /&gt;
[http://shop.keyboardpartner.de/epages/13705466.sf/de_DE/?ObjectPath=/Shops/13705466/Products/bass25midi Bass25 MIDI] ist mit einem eigenen MIDI-Controller und einer MIDI-Ausgangsbuchse ausgestattet. Er wird über ein 5-adriges MIDI-Kabel mit der HX3.5-Hauptplatine verbunden. Bass25 MIDI bietet Inline-Steckverbinder und einen 26-poligen Flachbandkabelanschluss für den alternativen Anschluss von Basspedal-Kontakten. Die 2-polige Inline-Stiftleiste PL9 bietet auch eine gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | PL1 Bass25 MIDI Tasten-Anschluss&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Tiefste Note C&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|C#&lt;br /&gt;
|-&lt;br /&gt;
! ...&lt;br /&gt;
|weitere Tasten&lt;br /&gt;
|-&lt;br /&gt;
!25&lt;br /&gt;
|Höchste Note C&lt;br /&gt;
|-&lt;br /&gt;
!26&lt;br /&gt;
|Gemeinsame Masse (busbar)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Statt an PL1 können die Tastaturkontakte auch an die Inline-Stiftleisten PL2 bis PL7 an die Lötpads vor den Stiftleisten angeschlossen werden (linker Pin PL2: tiefstes C). Die 2-polige Inline-Stiftleiste PL9 dient auch als gemeinsame Masse für die Stromschiene.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP3&#039;&#039;&#039; Lötbrücke muss geschlossen sein. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;JP4&#039;&#039;&#039; Lötbrücke muss geschlossen sein, wenn der Bass25 MIDI mit Phantomspeisung von der HX3-Platine, linke MIDI-Eingangsbuchse (von hinten gesehen), versorgt wird. MIDI-Phantomspeisung-Jumper auf der HX3-Platine müssen gesteckt sein. &lt;br /&gt;
&lt;br /&gt;
Für eine separate Stromversorgung (interne +5V oder externes 9V DC Steckernetzteil), öffnen Sie die &#039;&#039;&#039;JP4&#039;&#039;&#039;-Lötbrücke. Verwenden Sie die 2-polige Stiftleiste PL12 neben der MIDI OUT-Buchse für die interne +5V-Versorgung: Pin 1 (links, zur Diode weisend) ist VCC +5V, Pin 2 (rechts) ist Masse (siehe PDF-Schaltplan in [https://github.com/keyboardpartner/HX3/tree/master/PLATINEN/Bass25 unserem Github-Repo-Ordner PLATINEN/BASS25]).&lt;br /&gt;
&lt;br /&gt;
Eine +5V-MIDI-Phantomspeisung an den äußeren Pins des MIDI-Eingangs kann von der HX3-Hauptplatine durch Einsetzen von zwei &#039;&#039;&#039;zusätzlichen&#039;&#039;&#039; Jumpern auf HX3.5 PL18 &#039;&#039;&#039;Pins 7-8 und 9-10&#039;&#039;&#039; erhalten werden. Installieren Sie diese Steckbrücken nicht, wenn Sie andere MIDI-Geräte anschließen, die keine Phantomspeisung verwenden.&lt;br /&gt;
&lt;br /&gt;
===Sustain/Sostenuto/Cancel Taster===&lt;br /&gt;
&lt;br /&gt;
Der Anschluss &#039;&#039;&#039;AUXILIARY&#039;&#039;&#039; (PL16 bei HX3.5, PL21 bei HX3.7) steuert Sustain/Sostenuto und MIDI Cancel für jedes Manual (nur Fatar- und Scan61-Treiber). Beim MIDI-Scantreiber und HX3.7 ist dies der Ausgang für 7 Status-Leuchtdioden des MenuPanel.&lt;br /&gt;
&lt;br /&gt;
(Fuss)Taster müssen den betreffenden Eingang mit Masse verbinden, um die Funktion zu aktivieren:&lt;br /&gt;
&lt;br /&gt;
{|class=&amp;quot;wikitable&amp;quot; border=&amp;quot;1&amp;quot; cellpadding=&amp;quot;4&amp;quot; cellspacing=&amp;quot;0&amp;quot; style=&amp;quot;text-align:left;width: 25%;background-color:#ffffcc;&amp;quot;&lt;br /&gt;
!colspan=&amp;quot;10&amp;quot; style=&amp;quot;background-color:#d0d0d0;&amp;quot; | AUXILIARY&lt;br /&gt;
|-&lt;br /&gt;
!style=&amp;quot;width: 15%&amp;quot; | Pin&lt;br /&gt;
!Funktion&lt;br /&gt;
|-&lt;br /&gt;
!1&lt;br /&gt;
|Bit 0, Cancel MIDI Upper&lt;br /&gt;
|-&lt;br /&gt;
!2&lt;br /&gt;
|Bit 1, Cancel MIDI Lower&lt;br /&gt;
|-&lt;br /&gt;
!3&lt;br /&gt;
|Bit 2, Sostenuto Lower&lt;br /&gt;
|-&lt;br /&gt;
!4&lt;br /&gt;
|Bit 3, Sustain Lower&lt;br /&gt;
|-&lt;br /&gt;
!5&lt;br /&gt;
|Bit 4, Sostenuto Upper&lt;br /&gt;
|-&lt;br /&gt;
!6&lt;br /&gt;
|Bit 5, Sustain Upper&lt;br /&gt;
|-&lt;br /&gt;
!7&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!8&lt;br /&gt;
|not used&lt;br /&gt;
|-&lt;br /&gt;
!9&lt;br /&gt;
| +5V (not used)&lt;br /&gt;
|-&lt;br /&gt;
!10&lt;br /&gt;
|Common Gnd für Taster&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bitte beachten Sie: Diese Eingänge sind ungeschützt und &#039;&#039;&#039;können durch statische Aufladung, z.B. durch Einstecken eines Kabels, zerstört werden&#039;&#039;&#039;&#039;. Jeder als Fusstaster benutzte Eingang von AUXILIARY sollte durch eine Zenerdiode 4V7/250mW geschützt werden (Anode an Gnd, Kathodenring an Eingang).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7059</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7059"/>
		<updated>2026-02-18T13:16:03Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a &#039;&#039;&#039;factory reset&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;&#039;System Inits&#039;&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7058</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7058"/>
		<updated>2026-02-18T13:15:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a &#039;&#039;factory reset&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;System Inits&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7057</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7057"/>
		<updated>2026-02-18T13:15:21Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a factory reset:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;System Inits&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7056</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7056"/>
		<updated>2025-12-12T08:34:32Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den &#039;&#039;&#039;maximalen Wert&#039;&#039;&#039; (127), &#039;&#039;Test Generator Level&#039;&#039; auf &#039;&#039;&#039;-20,2 dB&#039;&#039;&#039; (3192) und TubeAmp und Speaker auf &#039;&#039;&#039;Bypass ON&#039;&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können, siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7055</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7055"/>
		<updated>2025-12-12T08:32:30Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorbereitung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den &#039;&#039;&#039;maximalen Wert&#039;&#039;&#039; (127), &#039;&#039;Test Generator Level&#039;&#039; auf &#039;&#039;&#039;-20,2 dB&#039;&#039;&#039; (3192) und TubeAmp und Speaker auf &#039;&#039;&#039;Bypass ON&#039;&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7054</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7054"/>
		<updated>2025-12-12T08:30:22Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Levels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Audio Levels==&lt;br /&gt;
&lt;br /&gt;
Levels indicated in Swell/Sweep analyzer are arbitrarily referenced to full 16 bit digital level with 0dB = clipping limit of 32767 counts. Indication will not align with external measurement of analog audio signals.&lt;br /&gt;
&lt;br /&gt;
For the following checks, set &#039;&#039;Swell Test&#039;&#039; (or swell pedal) and &#039;&#039;Master Volume&#039;&#039; to full (127), &#039;&#039;Test Generator Level&#039;&#039; to -20.2dB (3192), TubeAmp and Speaker to &#039;&#039;Bypass ON&#039;&#039;. If available, connect an external millivoltmeter to audio output jack to be observed.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;1024 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;checked&#039;&#039;&#039; (will bypass preamp/swell simulation), observed analog output level on main outputs should be about &#039;&#039;&#039;630mV RMS or -1.8dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;. Both will &#039;&#039;&#039;not&#039;&#039;&#039; vary sigificantly with frequency changes as there is no swell simulation.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;225 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;unchecked &#039;&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. It will vary with frequency due to preamp simulation.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7053</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7053"/>
		<updated>2025-12-12T08:27:49Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Messung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7052</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7052"/>
		<updated>2025-12-12T08:26:08Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Messung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7051</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7051"/>
		<updated>2025-12-12T08:26:00Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorbereitung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
==Messung==&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7050</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7050"/>
		<updated>2025-12-12T08:25:46Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Pegel */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
==Vorbereitung==&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
==Messung==&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7049</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7049"/>
		<updated>2025-12-12T08:24:48Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7048</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7048"/>
		<updated>2025-12-12T08:20:39Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Levels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Levels==&lt;br /&gt;
&lt;br /&gt;
Levels indicated in Swell/Sweep analyzer are arbitrary referenced to full 16 bit digital level with 0dB = clipping limit of 32767 counts. Indication will not align with external measurement of analog audio signals.&lt;br /&gt;
&lt;br /&gt;
For the following checks, set &#039;&#039;Swell Test&#039;&#039; (or swell pedal) and &#039;&#039;Master Volume&#039;&#039; to full (127), &#039;&#039;Test Generator Level&#039;&#039; to -20.2dB (3192), TubeAmp and Speaker to &#039;&#039;Bypass ON&#039;&#039;. If available, connect an external millivoltmeter to audio output jack to be observed.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;1024 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;checked&#039;&#039;&#039; (will bypass preamp/swell simulation), observed analog output level on main outputs should be about &#039;&#039;&#039;630mV RMS or -1.8dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;. Both will &#039;&#039;&#039;not&#039;&#039;&#039; vary sigificantly with frequency changes as there is no swell simulation.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;225 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;unchecked &#039;&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. It will vary with frequency due to preamp simulation.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7047</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7047"/>
		<updated>2025-12-12T07:53:40Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Creating a new Measurement */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Levels==&lt;br /&gt;
&lt;br /&gt;
With a &#039;&#039;Test Generator Level&#039;&#039; setting of -20dB, &#039;&#039;Measure external FX Loop&#039;&#039; checked (Preamp Sim Bypass), full &#039;&#039;Master Volume&#039;&#039;, TubeAmp and Speaker &#039;&#039;Bypass ON&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7046</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7046"/>
		<updated>2025-12-11T16:47:23Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7045</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7045"/>
		<updated>2025-12-11T16:46:37Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Loading Measurements and Reference Curvesn */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7044</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7044"/>
		<updated>2025-12-11T16:46:10Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Using EFX Input */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7043</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7043"/>
		<updated>2025-12-11T16:45:08Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7042</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7042"/>
		<updated>2025-12-11T16:43:48Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7041</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7041"/>
		<updated>2025-12-11T16:42:31Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7040</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7040"/>
		<updated>2025-12-11T16:41:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Setting up the License */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7039</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7039"/>
		<updated>2025-12-11T16:38:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7038</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7038"/>
		<updated>2025-12-11T16:38:11Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Installing the Licence */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7037</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7037"/>
		<updated>2025-12-11T16:17:50Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Installing the Licence==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7036</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7036"/>
		<updated>2025-12-11T16:16:29Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Installing the Licence==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7035</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7035"/>
		<updated>2025-12-11T16:15:36Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7034</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7034"/>
		<updated>2025-12-11T16:13:32Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* HX3 equalizer measurement */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7033</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7033"/>
		<updated>2025-12-11T16:13:21Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Measuring external devices */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7032</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7032"/>
		<updated>2025-12-11T16:13:09Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Saving swell settings in HX3 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring external devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7031</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7031"/>
		<updated>2025-12-11T16:12:49Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* EFX-Eingang nutzen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving swell settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring external devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7030</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7030"/>
		<updated>2025-12-11T16:10:34Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Schweller-Einstellungen in HX3 speichern */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving swell settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>