<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="de">
	<id>https://wiki.keyboardpartner.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bovist</id>
	<title>KeyboardPartner Wiki - Benutzerbeiträge [de]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.keyboardpartner.de/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bovist"/>
	<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Spezial:Beitr%C3%A4ge/Bovist"/>
	<updated>2026-04-30T09:18:49Z</updated>
	<subtitle>Benutzerbeiträge</subtitle>
	<generator>MediaWiki 1.39.1</generator>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7059</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7059"/>
		<updated>2026-02-18T13:16:03Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a &#039;&#039;&#039;factory reset&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;&#039;System Inits&#039;&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7058</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7058"/>
		<updated>2026-02-18T13:15:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a &#039;&#039;factory reset&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;System Inits&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7057</id>
		<title>HX3.6 First Aid (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_First_Aid_(english)&amp;diff=7057"/>
		<updated>2026-02-18T13:15:21Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* No Sound */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;You have installed the new board and there is no sound or some functions are faulty? Check the following settings with the HX3 Manager:&lt;br /&gt;
&lt;br /&gt;
=== HX3 Manager does not start or with error message ===&lt;br /&gt;
&lt;br /&gt;
* Hold down the SHIFT key when starting (double click &#039;&#039;hx3_manager.exe&#039;&#039;). This resets possibly faulty screen positions. This works only from HX3 Manager version #6.06.&lt;br /&gt;
* The HX3 Manager should be installed (unpacked/copied) in a directory whose path does not contain spaces or diacritical characters/umlauts, so for example &#039;&#039;D:\documents\hx3_stuff\&#039;&#039; would be OK.&lt;br /&gt;
&lt;br /&gt;
=== Known Bugs ===&lt;br /&gt;
&lt;br /&gt;
[[Datei:HX36_mod_dac.jpg|400px|thumb|right|&#039;&#039;&#039;HX3.6 board DAC modification if update to #14102023 does not help (click on picture to enlarge)&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
When playing notes, a few boards produce a &amp;quot;grainy&amp;quot; noise &#039;&#039;&#039;sometimes&#039;&#039;&#039; after switching on (i.e. sometimes every 3 to 10 power cycles). This is caused by timing issues from FPGA to DAC and DSP, and we solved it for every known case by improved I2S interfacing within FPGA structure. If &#039;&#039;&#039;updating the FPGA Sound Engine to #14102023&#039;&#039;&#039; does not help and you still experience such behaviour, a small hardware modification is necessary. This has to be done free of charge in our workshop.&lt;br /&gt;
&lt;br /&gt;
If you are confident and familiar with SMD soldering, you can also do this modification yourself (see picture on right): Remove resistors R1 and R8 (heat both sides with two soldering irons). Wire the solder joints from R1 and R8 to R34 (middle) as shown in picture with enamelled copper wire or thin (!) insulated wire. Do not use bare wire.&lt;br /&gt;
&lt;br /&gt;
===No/erraneous connection===&lt;br /&gt;
&lt;br /&gt;
* Is a scan board connected? Operation without scan board is only possible with HX3 Expander or MIDI scan driver installed.&lt;br /&gt;
* In normal operation, the blue LED on the HX3 mainboard flashes about once per second, as well as when sending MIDI data. If it is lit continuously, an analog control input is probably open and &amp;quot;floating&amp;quot;, which is why MIDI data is being sent all the time. In this case, connect the HX3 Manager with &amp;quot;Disable Analog Inputs on Connect&amp;quot; checked. This will temporarily set System Inits parameter #1503 to 0. &#039;&#039;&#039;Do not store System Inits with wrong #1503 value&#039;&#039;&#039;, otherwise analog controllers, swell pedal and foot switches &#039;&#039;&#039;will not work&#039;&#039;&#039;. &lt;br /&gt;
* If the blue LED flickers three times per second for a short time and is on otherwise, HX3.6 is in bootloader mode, because this was requested (encoder pressed during power-on) or FPGA Sound Engine or firmware are corrupted. A connection with the editor is then not possible.&lt;br /&gt;
&lt;br /&gt;
===Version Check===&lt;br /&gt;
* Is valid board information displayed in the HX3 Updater (version and serial numbers, min. activation Organ Licence OK)?&lt;br /&gt;
* Does the displayed scan driver match your scan board? If not, install matching Scan Driver.&lt;br /&gt;
&lt;br /&gt;
===No Sound===&lt;br /&gt;
&lt;br /&gt;
* Are the manual enables in MIDI Setup #1373 set to 7?&lt;br /&gt;
* Are the volume pots set to plausible values?&lt;br /&gt;
* In the &#039;&#039;GM/H100 Setup&#039;&#039; the values for &#039;&#039;GM Synth Output Mix Level&#039;&#039; #1490 and &#039;&#039;Organ Output Mix Level&#039;&#039; #1491 should be between 100 and 120. This sets the level at the last output mixer of the DSP.&lt;br /&gt;
&lt;br /&gt;
If that does not help, try a factory reset:&lt;br /&gt;
&lt;br /&gt;
* Copy the HX3 Manager app and all files included to your HD and start the HX3 Manager. Do not click connect. &lt;br /&gt;
* Start HX3 in bootloader mode, holding the rotary encoder down while power up. &lt;br /&gt;
* Uncheck the &amp;quot;Exit BL when done&amp;quot; checkbox. &lt;br /&gt;
* In the Update column, set ALL items from &amp;quot;FPGA sound engine&amp;quot; up to &amp;quot;Rotary Horn Filter&amp;quot; to YES. Leave the remaining 6 files (Failsafe and DSP/GM stuff) to NO.&lt;br /&gt;
* Click &amp;quot;Send DFU Pack&amp;quot; button. It will send an update of all files and install the MIDI driver.&lt;br /&gt;
&lt;br /&gt;
When done (display gone idle), turn encoder to right to exit bootloader mode. HX3 should start up normally as a MIDI expander (no keybed scanning). In HX3 Manager, check &#039;&#039;System Inits&#039;&#039;, button and analog assignments finally. For organs with Fatar os custom keybeds attached, install the appropriate scan driver.&lt;br /&gt;
&lt;br /&gt;
===Erraneous Operation===&lt;br /&gt;
* Are the System Inits correctly set in the HX3 Editor? Typical for an organ with 2 drawbar sets per manual is the following configuration:&lt;br /&gt;
 1496 = 0     / (not used)&lt;br /&gt;
 1497 = 0     / Vibrato Knob Mode&lt;br /&gt;
 1498 = 159   / CommonPreset Save/Restore Mask&lt;br /&gt;
 1499 = 0     / (RFU)&lt;br /&gt;
 1500 = 0     / (RFU)&lt;br /&gt;
 1501 = 23    / Various Configurations 1&lt;br /&gt;
 1502 = 5     / Various Configurations 2&lt;br /&gt;
 1503 = 2     / ADC Configuration&lt;br /&gt;
 1504 = 0     / 1st DB Set Voice Number (enabled when 0..15)&lt;br /&gt;
 1505 = 1     / 2nd DB Set Voice Number (enabled when 1..15)&lt;br /&gt;
 1506 = 0     / Pedal Drawbar Configuration&lt;br /&gt;
 1507 = 100   / ADC Scaling&lt;br /&gt;
 1508 = 4     / ADC Hysteresis&lt;br /&gt;
 1509 = 3     / HX3 Device Type&lt;br /&gt;
&lt;br /&gt;
===Pot/Drawbar Assignments===&lt;br /&gt;
&lt;br /&gt;
* When moving the (in case of 2 DB sets of the active) drawbars, the corresponding values of the &#039;&#039;Upper DB&#039;&#039;, &#039;&#039;Lower DB&#039;&#039; etc. must change. If not: Are the analog inputs activated (&#039;&#039;System Inits&#039;&#039; #1503) and correctly assigned (&#039;&#039;Analog Remap&#039;&#039;)? If necessary, check the raw values of the analog inputs in the editor tab &amp;quot;Input Monitor&amp;quot;. &lt;br /&gt;
 5000 = 0     / Analog Input 0 (UPR PL22-1) Function&lt;br /&gt;
 5001 = 1     / Analog Input 1 (UPR PL22-2) Function&lt;br /&gt;
 5002 = 2     / Analog Input 2 (UPR PL22-3) Function&lt;br /&gt;
 5003 = 3     / Analog Input 3 (UPR PL22-4) Function&lt;br /&gt;
 5004 = 4     / Analog Input 4 (UPR PL22-5) Function&lt;br /&gt;
 5005 = 5     / Analog Input 5 (UPR PL22-6) Function&lt;br /&gt;
 5006 = 6     / Analog Input 6 (UPR PL22-7) Function&lt;br /&gt;
 5007 = 7     / Analog Input 7 (UPR PL22-8) Function&lt;br /&gt;
 5008 = 8     / Analog Input 8 (UPR PL22-9) Function&lt;br /&gt;
 5009 = 80    / Analog Input 9 (UPR PL22-10) Function&lt;br /&gt;
 5010 = 81    / Analog Input 10 (UPR PL22-11) Function&lt;br /&gt;
 ...&lt;br /&gt;
 5024 = 255   / MPX Input 0 Function&lt;br /&gt;
&lt;br /&gt;
===Button Assignments===&lt;br /&gt;
&lt;br /&gt;
* Are buttons and switches in Switch Remap assigned correctly? The button codes for Upper/Lower/Pedal Voices and Common Presets &#039;&#039;&#039;have changed&#039;&#039;&#039; to make room for the new Organ and Speaker models. Check all preset and voice assignments (values from 100 to 121) of the &#039;&#039;Switch Remap&#039;&#039; parameters #5100..5195 in the editor.&lt;br /&gt;
* Here is an example for the default assignment &#039;&#039;&#039;with 4 preset buttons on Panel16&#039;&#039;&#039;:&lt;br /&gt;
&lt;br /&gt;
 5132 = 0     / Input 32 (onboard Pin PL25-1) Function&lt;br /&gt;
 5133 = 1     / Input 33 (onboard Pin PL25-2) Function&lt;br /&gt;
 5134 = 2     / Input 34 (onboard Pin PL25-3) Function&lt;br /&gt;
 5135 = 3     / Input 35 (onboard Pin PL25-4) Function&lt;br /&gt;
 5136 = 4     / Input 36 (onboard Pin PL25-5) Function&lt;br /&gt;
 5137 = 5     / Input 37 (onboard Pin PL25-6) Function&lt;br /&gt;
 5138 = 6     / Input 38 (onboard Pin PL25-7) Function&lt;br /&gt;
 5139 = 7     / Input 39 (onboard Pin PL25-8) Function&lt;br /&gt;
 5140 = 104   / Input 40 (onboard Pin PL26-1) Function&lt;br /&gt;
 5141 = 104   / Input 41 (onboard Pin PL26-2) Function&lt;br /&gt;
 5142 = 104   / Input 42 (onboard Pin PL26-3) Function&lt;br /&gt;
 5143 = 104   / Input 43 (onboard Pin PL26-4) Function&lt;br /&gt;
 5144 = 12    / Input 44 (onboard Pin PL26-5) Function&lt;br /&gt;
 5145 = 13    / Input 45 (onboard Pin PL26-6) Function&lt;br /&gt;
 5146 = 14    / Input 46 (onboard Pin PL26-7) Function&lt;br /&gt;
 5147 = 15    / Input 47 (onboard Pin PL26-8) Function&lt;br /&gt;
&lt;br /&gt;
=== Shifted Octaves ===&lt;br /&gt;
&lt;br /&gt;
* When using &#039;&#039;&#039;Fatar keybeds&#039;&#039;&#039;: Are the &#039;&#039;Octave Shifts&#039;&#039; (parameters #1174 and #1175 under *Tabs*) turned off? An older &#039;&#039;presets.dat&#039;&#039; contained wrong settings here. In this case set parameter #1174 and #1175 in the editor to 0 (OFF) and save with &#039;&#039;Store Defaults&#039;&#039;, also in the &#039;&#039;HX3 Panel&#039;&#039; or the MenuPanel under preset 0. As long as no own presets have been created, it is best to update the complete presets with the &#039;&#039;presets.dat&#039;&#039; file from a current HX3 manager (Updater menu &#039;&#039;Update via USB or FTDI Cable&#039;&#039;).&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7056</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7056"/>
		<updated>2025-12-12T08:34:32Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den &#039;&#039;&#039;maximalen Wert&#039;&#039;&#039; (127), &#039;&#039;Test Generator Level&#039;&#039; auf &#039;&#039;&#039;-20,2 dB&#039;&#039;&#039; (3192) und TubeAmp und Speaker auf &#039;&#039;&#039;Bypass ON&#039;&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können, siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7055</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7055"/>
		<updated>2025-12-12T08:32:30Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorbereitung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den &#039;&#039;&#039;maximalen Wert&#039;&#039;&#039; (127), &#039;&#039;Test Generator Level&#039;&#039; auf &#039;&#039;&#039;-20,2 dB&#039;&#039;&#039; (3192) und TubeAmp und Speaker auf &#039;&#039;&#039;Bypass ON&#039;&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7054</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7054"/>
		<updated>2025-12-12T08:30:22Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Levels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Audio Levels==&lt;br /&gt;
&lt;br /&gt;
Levels indicated in Swell/Sweep analyzer are arbitrarily referenced to full 16 bit digital level with 0dB = clipping limit of 32767 counts. Indication will not align with external measurement of analog audio signals.&lt;br /&gt;
&lt;br /&gt;
For the following checks, set &#039;&#039;Swell Test&#039;&#039; (or swell pedal) and &#039;&#039;Master Volume&#039;&#039; to full (127), &#039;&#039;Test Generator Level&#039;&#039; to -20.2dB (3192), TubeAmp and Speaker to &#039;&#039;Bypass ON&#039;&#039;. If available, connect an external millivoltmeter to audio output jack to be observed.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;1024 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;checked&#039;&#039;&#039; (will bypass preamp/swell simulation), observed analog output level on main outputs should be about &#039;&#039;&#039;630mV RMS or -1.8dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;. Both will &#039;&#039;&#039;not&#039;&#039;&#039; vary sigificantly with frequency changes as there is no swell simulation.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;225 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;unchecked &#039;&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. It will vary with frequency due to preamp simulation.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7053</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7053"/>
		<updated>2025-12-12T08:27:49Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Messung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;aktiviert&#039;&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7052</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7052"/>
		<updated>2025-12-12T08:26:08Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Messung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
===Messung===&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7051</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7051"/>
		<updated>2025-12-12T08:26:00Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorbereitung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
===Vorbereitung===&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
==Messung==&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7050</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7050"/>
		<updated>2025-12-12T08:25:46Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Pegel */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Audio-Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
==Vorbereitung==&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
==Messung==&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7049</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7049"/>
		<updated>2025-12-12T08:24:48Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Pegel==&lt;br /&gt;
&lt;br /&gt;
Die im Swell/Sweep-Analysator angezeigten Pegel beziehen sich willkürlich auf den vollen 16-Bit-Digitalpegel mit 0 dB = Clipping-Grenze von 32767 Counts. Die Anzeige stimmt nicht mit externen Messungen analoger Audiosignale überein.&lt;br /&gt;
&lt;br /&gt;
Stellen Sie für die folgenden Überprüfungen &#039;&#039;Swell Test&#039;&#039; (oder Swell-Pedal) und &#039;&#039;Master Volume&#039;&#039; auf den maximalen Wert (127), &#039;&#039;Test Generator Level&#039;&#039; auf -20,2 dB (3192) und TubeAmp und Speaker auf &#039;&#039;Bypass ON&#039;&#039;. Schließen Sie, falls verfügbar, ein externes Millivoltmeter an die zu prüfende Audio-Ausgangsbuchse an.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;1024 Hz&#039;&#039;&#039; und &#039;&#039;&#039;aktivierter&#039;&#039;&#039; Option &#039;&#039;Measure external FX Loop&#039;&#039; (umgeht die Vorverstärker-/Swell-Simulation) sollte der beobachtete analoge Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;630 mV RMS oder -1,8 dB&#039;&#039;&#039; betragen. Der beobachtete Ausgangspegel am separaten Orgelausgang ist mit &#039;&#039;&#039;170 mV RMS oder -13 dB&#039;&#039;&#039; niedriger. Beide variieren &#039;&#039;&#039;nicht&#039;&#039;&#039; wesentlich mit Frequenzänderungen, da keine Swell-Simulation vorhanden ist.&lt;br /&gt;
&lt;br /&gt;
Bei einer &#039;&#039;Test Generator Frequency&#039;&#039; von &#039;&#039;&#039;225 Hz&#039;&#039;&#039; und &#039;&#039;Externe FX-Schleife messen&#039;&#039; &#039;&#039;&#039;nicht aktiviert&#039;&#039;&#039; beträgt der gemessene Ausgangspegel an den Hauptausgängen etwa &#039;&#039;&#039;750 mV RMS oder -0,5 dB&#039;&#039;&#039;. Er variiert aufgrund der Vorverstärkersimulation stark mit der Frequenz.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7048</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7048"/>
		<updated>2025-12-12T08:20:39Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Levels */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Levels==&lt;br /&gt;
&lt;br /&gt;
Levels indicated in Swell/Sweep analyzer are arbitrary referenced to full 16 bit digital level with 0dB = clipping limit of 32767 counts. Indication will not align with external measurement of analog audio signals.&lt;br /&gt;
&lt;br /&gt;
For the following checks, set &#039;&#039;Swell Test&#039;&#039; (or swell pedal) and &#039;&#039;Master Volume&#039;&#039; to full (127), &#039;&#039;Test Generator Level&#039;&#039; to -20.2dB (3192), TubeAmp and Speaker to &#039;&#039;Bypass ON&#039;&#039;. If available, connect an external millivoltmeter to audio output jack to be observed.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;1024 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;checked&#039;&#039;&#039; (will bypass preamp/swell simulation), observed analog output level on main outputs should be about &#039;&#039;&#039;630mV RMS or -1.8dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;. Both will &#039;&#039;&#039;not&#039;&#039;&#039; vary sigificantly with frequency changes as there is no swell simulation.&lt;br /&gt;
&lt;br /&gt;
With &#039;&#039;Test Generator Frequency&#039;&#039; of &#039;&#039;&#039;225 Hz&#039;&#039;&#039;, &#039;&#039;Measure external FX Loop&#039;&#039; &#039;&#039;&#039;unchecked &#039;&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. It will vary with frequency due to preamp simulation.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7047</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7047"/>
		<updated>2025-12-12T07:53:40Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Creating a new Measurement */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to &#039;&#039;Bypass&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on &#039;&#039;Sweep New&#039;&#039;. The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the &#039;&#039;Short&#039;&#039; setting, while the &#039;&#039;Fine&#039;&#039; selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Levels==&lt;br /&gt;
&lt;br /&gt;
With a &#039;&#039;Test Generator Level&#039;&#039; setting of -20dB, &#039;&#039;Measure external FX Loop&#039;&#039; checked (Preamp Sim Bypass), full &#039;&#039;Master Volume&#039;&#039;, TubeAmp and Speaker &#039;&#039;Bypass ON&#039;&#039;, observed output level on main outputs is about &#039;&#039;&#039;750mV RMS or -0.5dB&#039;&#039;&#039;. Observed output level on separate organ output is lower at &#039;&#039;&#039;170 mV RMS or -13dB&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7046</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7046"/>
		<updated>2025-12-11T16:47:23Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us, see [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7045</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7045"/>
		<updated>2025-12-11T16:46:37Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Loading Measurements and Reference Curvesn */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curves===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7044</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7044"/>
		<updated>2025-12-11T16:46:10Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Using EFX Input */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various (nonsensical) settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7043</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7043"/>
		<updated>2025-12-11T16:45:08Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; (contained in ZIP of firmmware update). The larger window allows for a clearer display, operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories and uses the same license code as for &#039;&#039;HX3 Manager&#039;&#039;.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7042</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7042"/>
		<updated>2025-12-11T16:43:48Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung (im ZIP der Firmware enthalten). Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse und verwendet die Lizenznummer des Managers.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7041</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7041"/>
		<updated>2025-12-11T16:42:31Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie [https://shop.keyboardpartner.de/p/hx3-sweep-analyzer-lizenz bei uns bestellen können] (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7040</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7040"/>
		<updated>2025-12-11T16:41:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Setting up the License */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you [https://shop.keyboardpartner.de/en/p/hx3-sweep-analyzer-license can order from us] (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7039</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7039"/>
		<updated>2025-12-11T16:38:41Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up the License]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7038</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7038"/>
		<updated>2025-12-11T16:38:11Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Installing the Licence */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Setting up the License==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7037</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7037"/>
		<updated>2025-12-11T16:17:50Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweep Analyzer */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Installing the Licence==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer as standalone program&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test generator and analysis functions are also available as a standalone program in the form of the application &#039;&#039;HX3_SweepAnalyzer.exe.&#039;&#039; The larger window allows for a clearer display, and operation is the same as above. The &#039;&#039;HX3 Manager&#039;&#039; must not be connected when starting. You can install and use this program separately from the HX3 Manager; it only requires the &#039;&#039;user&#039;&#039; and &#039;&#039;editor_files&#039;&#039; directories.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7036</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7036"/>
		<updated>2025-12-11T16:16:29Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Installing the Licence==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Installing the Licences for Sweep and Tapering Editor&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7035</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7035"/>
		<updated>2025-12-11T16:15:36Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
The test tone generator and level measurement function are always available. However, sweeps and auto sweeps require a license, which you can order from us (be sure to &#039;&#039;&#039;include the serial number&#039;&#039;&#039; of your HX3!). Entering the license number unlocks the sweep functions.&lt;br /&gt;
&lt;br /&gt;
After connecting your device in the HX3 Manager start window, click on &#039;&#039;Manager License.&#039;&#039; Your device serial number and, if applicable, your name should now appear in the About dialog box as the “Customer Name.” Now enter the “Customer Name” and “Sweep Generator License Key” exactly as they appear in our confirmation email. Click on &#039;&#039;&#039;Activate&#039;&#039;&#039;. A check mark will now appear next to the license number. Close the window with &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
The license data is stored in the file &#039;&#039;HX3_userinfo.txt&#039;&#039; in the &#039;&#039;editor_files&#039;&#039; directory. Keep a copy of this file in a safe place. The file can be transferred when selling the software or copied to the new HX3 Manager directory (again in &#039;&#039;editor_files&#039;&#039;) when installing an update (from a ZIP file) in order to transfer the license for the update.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7034</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7034"/>
		<updated>2025-12-11T16:13:32Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* HX3 equalizer measurement */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 Equalizer Measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7033</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7033"/>
		<updated>2025-12-11T16:13:21Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Measuring external devices */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring External Devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7032</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7032"/>
		<updated>2025-12-11T16:13:09Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Saving swell settings in HX3 */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving Swell Settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring external devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7031</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7031"/>
		<updated>2025-12-11T16:12:49Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* EFX-Eingang nutzen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving swell settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==Using EFX Input==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Generator measuring the internal HX3 Equalizer with various settings&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Using the “EFX Input” effects loop input (HX3.7 only), it is also possible to measure external devices and the HX3 equalizer. If the “Measure External FX Loop” checkbox is active, the level detector is set to the HX3&#039;s effects loop input, and the test generator&#039;s unmodified signal appears at the organ output. The internal preamp simulation is ‘’&#039;switched off&#039;‘’, so the frequency response is completely linear.&lt;br /&gt;
&lt;br /&gt;
===Measuring external devices===&lt;br /&gt;
&lt;br /&gt;
To test, connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a ‘’&#039;linear frequency response&#039;‘’.&lt;br /&gt;
&lt;br /&gt;
With this configuration, you can measure the frequency response of an effects device that is looped between “Organ” and “EFX Input,” for example. Professionals can even measure the frequency response of their historic organ; to do this, the output signal at “Organ” is fed via a 1 kOhm resistor to one of the organ&#039;s middle preset bus bars and picked up again at ‘’&#039;one&#039;‘’ of the G-G outputs and ground. Note that the output level at the G connection is very high, so the EFX level control must be turned to the left.&lt;br /&gt;
&lt;br /&gt;
===HX3 equalizer measurement===&lt;br /&gt;
&lt;br /&gt;
The internal equalizer of the HX3 DSP can be difficult to adjust due to its parametric structure, especially with regard to quality (peak) and exact frequency. A sweep greatly simplifies critical settings.&lt;br /&gt;
&lt;br /&gt;
Connect the “Organ” output directly to “EFX Input” using a jack cable and set the effect level control to the right stop. A sweep should now produce a linear frequency response. Now switch the equalizer bypass to “Off” and play around with the equalizer settings (on the device or via the HX3 Manager panel). This will produce curves that clearly show the equalizer settings.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7030</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7030"/>
		<updated>2025-12-11T16:10:34Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Schweller-Einstellungen in HX3 speichern */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Saving swell settings in HX3===&lt;br /&gt;
&lt;br /&gt;
Unlike earlier firmware versions, a fixed swell loudness curve (editor parameter #1384, now obsolete) is no longer used. Instead, individual swell behavior can be set for each organ model using the new parameters #1091 to #1095 (found under “Volume Pots”), similar to the previous trim cap and minimal swell settings.&lt;br /&gt;
&lt;br /&gt;
Once you have found a satisfactory setting, you can save it to the HX3 board using “Store to Organ”. The button and selection of organ models using the drop-down menu have the same function as the controls of the same name in the “Organs” tab and are only provided here again for convenience, so that organ models can be quickly compared.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7029</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7029"/>
		<updated>2025-12-11T16:10:10Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Auto-Sweep durchführen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto Sweep===&lt;br /&gt;
&lt;br /&gt;
This function is used to check the frequency response at different threshold settings (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), which is important for the loudness correction of the AO28 preamp. Eight “runs” are performed, each with a different threshold setting (parameter #1600). This results in a set of curves as shown in the image above. To do this, click on “Sweep Auto.” The process can be canceled at any time by clicking on “Stop.”&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7028</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7028"/>
		<updated>2025-12-11T16:09:43Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Einzelnen Sweep durchführen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Single Sweep===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Single.” The test generator generates a series of frequencies based on the table, lists the measured values in the table, and displays the resulting measurement curve in the graph. Each new click on “Sweep Single” generates another series of measurements (up to 8 “runs”), allowing you to immediately compare different preamp parameters or different threshold settings. In any case, the dimmed display of a previously ‘loaded’ dimmed measurement series in the graph is not overwritten (only when you click on “New”).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7027</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7027"/>
		<updated>2025-12-11T16:08:59Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Sweeps */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequency sweeps determine the amplitude response of audio electronics at different frequencies. The frequency response is particularly important for the sound impression in preamp simulation. In most electromagnetic organs, a moderate drop toward higher frequencies can be observed from around 250 Hz; This is caused by both the preamp and the drawbar matching transformers and is entirely desirable. &lt;br /&gt;
&lt;br /&gt;
A license is required for sweeps and auto sweeps, which you can order from us (be sure to include the serial number of your HX3!). See also [[#Setting up a license]]. &lt;br /&gt;
&lt;br /&gt;
===Measuring the frequency response of the preamp simulation===&lt;br /&gt;
&lt;br /&gt;
Select the “Preamp out” input using the drop-down menu at the top left. The “Level Detect” bar should now display a level that depends on the threshold setting. You can change the level and frequency of the test signal (sine wave) using the “Test Generator Level” and “Test Generator Frequency” trackbars. With the threshold set to maximum, set the frequency to 225 Hz and adjust the “Test Generator Level” so that a “Level Detect” of approximately -10dB is displayed. The level will change slightly as you tune the test generator.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7026</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7026"/>
		<updated>2025-12-11T16:05:39Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Neue Messung anlegen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Creating a new Measurement===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7025</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7025"/>
		<updated>2025-12-11T16:05:20Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Preface */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Starting with sound engine version #11122025 (FPGA) and firmware 7.060, a &#039;&#039;&#039;sine wave test generator&#039;&#039;&#039; is built into HX3, which is used to check threshold settings (range, loudness, AO28 frequency response), vibrato, phasing rotors, and external effects devices. This feature was initially intended for development purposes only, but we have now included it in the official Manager version. It is even possible to check the frequency response of a historical organ by switching the effects input to the measurement signal (see below). The internal sine wave generator with tunable frequency is fed internally before PHR and vibrato effects when the Sweep tab is active in the HX3 Manager, as shown in the adjacent image. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Attention:&#039;&#039;&#039; After selecting the “Swell Sweep” tab, a rather loud test tone will be heard. Leaving the tab will turn it off again.&lt;br /&gt;
&lt;br /&gt;
===Loading Measurements and Reference Curvesn===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Load” and select one of the supplied “sweep_xxx.csv” files in the user directory. This fills the measurement table below and displays a dimmed set of curves.&lt;br /&gt;
&lt;br /&gt;
===Saving of Measurements ===&lt;br /&gt;
&lt;br /&gt;
Click on “Sweep Save.” The table will be saved as a CSV file (text, importable into Excel).&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
For initial measurements, switch off Reverb, Vibrato, and Phasing Rotor and set the internal equalizer to “Bypass.”&lt;br /&gt;
&lt;br /&gt;
A new measurement always uses the frequencies specified in the “Freq Hz” column, so you can also create your own frequency curves or use those from an existing measurement series. You can create a new table by clicking on “Sweep New.” The number of measurement points (table rows) depends on the adjacent drop-down menu. You can achieve particularly fast, rather rough measurements with the “Short” setting, while the “Fine” selection produces a significantly finer frequency resolution. The table is generated algorithmically, but you can change (and save) individual values in the frequency table as you wish.&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7024</id>
		<title>HX3 Sweep Generator (english)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator_(english)&amp;diff=7024"/>
		<updated>2025-12-11T16:01:28Z</updated>

		<summary type="html">&lt;p&gt;Bovist: Die Seite wurde neu angelegt: „&amp;#039;&amp;#039;&amp;#039; Sweep Generator Tab of HX3 Manager 7.21&amp;#039;&amp;#039;&amp;#039;  ==Preface==  Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &amp;#039;&amp;#039;&amp;#039;Sinus-Testgenerator&amp;#039;&amp;#039;&amp;#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun abe…“&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep Generator Tab of HX3 Manager 7.21&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Preface==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_Hauptseite_(deutsch)&amp;diff=7023</id>
		<title>HX3.6 Hauptseite (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_Hauptseite_(deutsch)&amp;diff=7023"/>
		<updated>2025-12-11T16:00:11Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Dokumente, Updates und Anleitungen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx36_mainboard_slant.JPG|400px|thumb|right|&#039;&#039;&#039;HX3 mk5 mainboard&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
=== Features ===&lt;br /&gt;
&lt;br /&gt;
HX3.6 (HX3 mk6) ist das Nachfolgemodell des bekannten HX3 mk5 Boards. Bei gleicher Größe und Form bietet es höhere Performance und mehr Flexibilität aufgrund der Ausstattung mit einem größeren XILINX FPGA-Chip der 7. Generation und einem deutlich leistungsfähigeren ARM-Controller für die Abfrage der Bedienelemente.&lt;br /&gt;
&lt;br /&gt;
Optional (mit Extended Licence) ist der neue HX3 TrueOrgan Klanggenerator imstande, alle elektromagnetischen Orgeln nachzubilden, inklusive der berühmten H100, dazu Combo-Orgeln und Konzertorgeln der 70er und 80er Jahre wie Böhm Orchester und Wersi Helios. Er erzeugt bis zu 15 Fußlagen und ermöglicht bis zu 12 Zugriegel pro Manual mit individuellen Mixturen, inklusive Phasing-Vibrato (WersiVoice, Böhm Phasing Rotor). Mechanische und elektronische Tastung können simultan genutzt werden. Auf allen Zugriegeln sind ADSR-Hüllkurven verfügbar, außerdem H100-Perkussion sowie „Harp Sustain“. Diverse Tongenerator-Wellenformen stehen zur Auswahl, für „käsige“ Combo-Orgeln ebenso wie für die klangstarken Konzertorgeln.&lt;br /&gt;
&lt;br /&gt;
In vielen Details ist HX3.6 kompatibel mit dem älteren HX3.5 Board (die meisten Peripherie-Anschlüsse, Pinout der Steckverbinder, mechanische Dimensionen). Allerdings gibt es zusätzliche Anschlüsse und die Nummerierung hat sich geändert. Der Editor im HX3.6-Manager verschafft Zugang zu den Parametern, deren Zahl drastisch gewachsen ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Die HX3.6-Komponenten sind zur Installation durch erfahrene Techniker gedacht. PC-Kentnisse werden vorausgesetzt, da eventuell Software-Bestandteile installiert und konfiguriert werden müssen.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Technische Daten ===&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Größe:&#039;&#039;&#039; 200 x 100 mm&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Stromversorgung:&#039;&#039;&#039; 5V/400mA or 9-12V/300mA (ohne Peripherie)&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Klangerzeugung:&#039;&#039;&#039; HX3 mk6 Sound Engine, Hardware-Emulation (Physical Modeling) durch FPGA der 7. Generation. Je 61 Töne auf Ober-/Untermanual ebenso wie Pedal. 15 Harmonische pro Taste, Hammond-typische Perkussion auf allen Harmonischen. Tastung auf allen Fußlagen wählbar zwischen &amp;quot;mechanisch&amp;quot; (Hammond-typische Tastenkontakte) oder elektronisch (LSI/Transistororgeln). Die  elektronische Tastung nutzt separate Hüllkurven (ADSR) für jede Fußlage und jede Taste (915 ADSR/VCA-Schaltkreise pro Manual).&lt;br /&gt;
&lt;br /&gt;
Quadcore-DSP mit 64 MByte Sample-Speicher für Hall/EFX und 128 General-MIDI-Stimmen (GM2), 81-fach polyphon. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschlüsse:&#039;&#039;&#039; 6,3mm-Buchse für Fußschalter, 6,3mm-Buchse für Schwellerpedal (Yamaha FC-7 oder ähnlich), DIN-5-pol. MIDI IN, MIDI IN/OUT, DC-Buchse für 5V- oder 9V-Steckernetzteil min. 500mA, 6,3mm-Buchsen für  Stereo-Audioausgang. USB-B-Buchse (bei Bedarf einzulöten). Anschlüsse auf dem Board für Stromversorgung 5V und 9...12V, bis zu 24 Zugriegel/Potentiometer (erweiterbar auf bis zu 88 Zugriegel/Potentiometer), 16 Taster (erweiterbar auf bis zu 64 Taster), 6-fach Vibrato-Drehschalter, I2C Bussystem für Menüpanel und Anschluss von Preset-Boards (kompatibel mit unseren Preset12-2- und Preset16-Boards).&lt;br /&gt;
&lt;br /&gt;
== Dokumente, Updates und Anleitungen ==&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Installationsanleitung]]&#039;&#039;&#039; Mainboard Hardware-Installation&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[MPX Bus (deutsch)]]&#039;&#039;&#039; Verwendung von MPX-Baugruppen (analoge Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[I2C Bus (deutsch)]]&#039;&#039;&#039; Verwendung von I2C-Baugruppen (digitale Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[Scan Boards (deutsch)]]&#039;&#039;&#039; Verwendung von Keyboard-Scan-Platinen&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Backgrounder (deutsch)]]&#039;&#039;&#039; Grundlegende Informationen über HX3 Sound Engine ab Version 3.5 resp. Böhm RealOrgan&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Migration Guide (deutsch)]]&#039;&#039;&#039; Wichtige Hinweise für den Umstieg von HX3.5 auf HX3.6&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 First Aid (deutsch)]]&#039;&#039;&#039; Update oder Einbau eines neuen Boards arbeiten fehlerhaft? Zuerst hier lesen!&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Extension Board (deutsch)]]&#039;&#039;&#039; Installation, auch gültig für HX3.6&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3 MIDI-Implementierung]]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Sweep Generator]]&#039;&#039;&#039; Verwendung des eigebauten Sweep-Generators zur Frequenzganganalyse (ab HX3.6, vorläufig)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Bootloader Update (deutsch)]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über USB&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6/3.7 Verwendung von SD-Karten]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über SD-Karte, Verwendung der INI-Skripte&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/ HX3 Update Page]&#039;&#039;&#039; Aktuelle Updates, Anleitungen/Handbücher, Zeichnungen und Tools&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Mainboard.pdf HX3.6 Mainboard Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_MIDI_Expander.pdf HX3.6 MIDI Expander Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Manager.pdf HX3.6 Manager Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039; für Parametereinstellung, Updates und Finalisierung&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/WiFi_Modul_Einbauanleitung.pdf HX3.5/HX3.6 WiFi Interface, nachträgliche Installation]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 HX3 Schaltbilder]&#039;&#039;&#039;, vollständige Schaltbilder für alle Boards&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/index.php?dir=Manuals%20%28Anleitungen%29/Older%20products Manuals für ältere Produkte (PDFs), XB2 Kit und andere]&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.7_Hauptseite_(deutsch)&amp;diff=7022</id>
		<title>HX3.7 Hauptseite (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.7_Hauptseite_(deutsch)&amp;diff=7022"/>
		<updated>2025-12-11T15:59:52Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Dokumente, Updates und Anleitungen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx37_mb_slant_2k.JPG|600px|thumb|right|HX3.7 Mainboard]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
HX3.7 (HX3 mk7) ist das Nachfolgemodell der bekannten HX3 mk5/mk6 Boards. Bei gleicher Größe und Form bietet es höhere Performance und mehr Flexibilität aufgrund der Ausstattung mit einem größeren XILINX FPGA-Chip der 7. Generation und einem deutlich leistungsfähigeren ARM-Controller für die Abfrage der Bedienelemente.&lt;br /&gt;
&lt;br /&gt;
Optional (mit Extended Licence) ist der neue HX3 TrueOrgan Klanggenerator imstande, alle elektromagnetischen Orgeln nachzubilden, inklusive der berühmten H100, dazu Combo-Orgeln und Konzertorgeln der 70er und 80er Jahre wie Böhm Orchester und Wersi Helios. Er erzeugt bis zu 15 Fußlagen und ermöglicht bis zu 12 Zugriegel pro Manual mit individuellen Mixturen, inklusive Phasing-Vibrato (WersiVoice, Böhm Phasing Rotor). Mechanische und elektronische Tastung können simultan genutzt werden. Auf allen Zugriegeln sind ADSR-Hüllkurven verfügbar, außerdem H100-Perkussion sowie „Harp Sustain“. Diverse Tongenerator-Wellenformen stehen zur Auswahl, für „käsige“ Combo-Orgeln ebenso wie für die klangstarken Konzertorgeln.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Die HX3.6-Komponenten sind zur Installation durch erfahrene Techniker gedacht. PC-Kentnisse werden vorausgesetzt, da eventuell Software-Bestandteile installiert und konfiguriert werden müssen.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Merkmale==&lt;br /&gt;
&lt;br /&gt;
Das hochintegrierte HX3.7-Mainboard ersetzt das bisherige HX3.6-Mainboard und sollte mit den meisten bestehenden Installationen kompatibel sein. Die Basisplatine HX3.7 bietet 2 Audio-Ausgangskanäle wie HX3.6, während die &#039;&#039;&#039;HX3.7 EFX&#039;&#039;&#039; Version 4-Kanal-DACs, vollständige Leslie-Lautsprecherkontrollschaltungen und eine Effekt-Insert-Schleife mit zusätzlichem ADC zwischen internem Röhrenverstärker- und interner Rotary-Simulation bietet. Dies ermöglicht die separate Nutzung der Rotationssimulation auch für externe Musikinstrumente. Die HX3.7-Basisversion kann ab Werk zu HX3.7 EFX aufgerüstet werden.&lt;br /&gt;
&lt;br /&gt;
HX3.7 bietet keine „alten“ Taster-/Schaltereingänge (wie &#039;&#039;&#039;Panel16&#039;&#039;&#039;) und keine klassischen analogen Zugriegel-Eingänge mehr. Stattdessen verlässt es sich auf I2C-Bus-Schnittstellen auf externen Panels (wie Preset16, Extern16 oder VibratoSwitch) und analoge MPX-Bus-Schaltungen, wie sie auf PTX-, ANX-, DBX9- und DBX12-Drawbar-Boards zu finden sind. Für bestehende OEM-Installationen bieten wir ein Interface (&#039;&#039;&#039;LegacyBoard&#039;&#039;&#039;) mit Anschlüssen für Legacy-Hardware an. &lt;br /&gt;
&lt;br /&gt;
===Gemeinsame Merkmale mit HX3.5/HX3.6===&lt;br /&gt;
&lt;br /&gt;
* Gleicher HX3-Manager, gleiche Firmware und gleiche FPGA-Sound-Engine&lt;br /&gt;
* Gleiche Platinengröße, gleiche Befestigungslöcher&lt;br /&gt;
* Gleiche Lage der DC-, USB-, Audio- und MIDI-Anschlüsse&lt;br /&gt;
* MenuPanel/Preset-Bus-Anschluss (I2C)&lt;br /&gt;
* Analoger MPX Bus für neuere DBX, PTX und ANX Boards&lt;br /&gt;
* Auxiliary MIDI Out, Fatar Scan und Pedal Scan Anschlüsse&lt;br /&gt;
* Eigener Signalprozessor (DSP) für Hall, GM-Voices und USB-Handling&lt;br /&gt;
&lt;br /&gt;
===Weggelassene Merkmale===&lt;br /&gt;
&lt;br /&gt;
* Keine Onboard-Zugriegeleingänge&lt;br /&gt;
* Keine Onboard-Taster/Schalter-Eingänge&lt;br /&gt;
* Kein ExtensionBoard-Anschluss (Leslie-Steuerung und Kopfhörerverstärkerschaltung jetzt auf der Platine integriert)&lt;br /&gt;
&lt;br /&gt;
===Zusätzliche Eigenschaften===&lt;br /&gt;
&lt;br /&gt;
* Stereo-Kopfhörerverstärker&lt;br /&gt;
* Verbesserte DACs und Audio-Verstärker/Filter&lt;br /&gt;
* 3 Onboard-MIDI-Anschlüsse (2x IN, 1x OUT), MIDI OUT kann alternativ auf JackExtension montiert werden&lt;br /&gt;
* Onboard-Audio-Ausgangsbuchsen können als L/R-Mono-Buchsen &#039;&#039;&#039;oder&#039;&#039;&#039; Stereo-L/R und Stereo-Kopfhörerbuchse gejumpert werden&lt;br /&gt;
* Anschluss von Zugriegeln und Tastern nur noch über Zusatzplatinen (MPX- und I2C-Bus)&lt;br /&gt;
* Integrierte Funktionen der erweiterten &#039;&#039;&#039;HX3.7 EFX&#039;&#039;&#039; Version:&lt;br /&gt;
** Integrierte 11-polige Leslie™-Steuerung, ExtensionBoard-Pinout auf 14-poliger Stiftleiste &#039;&#039;&#039;PL1&#039;&#039;&#039;&lt;br /&gt;
** Zusätzlicher DAC (Ausgänge für normales Orgel- und Pedalsignal), insgesamt 4 Audio-Ausgangskanäle&lt;br /&gt;
** Insert-Loop (Mono-Effekt-Einschleifweg zwischen Röhrenverstärkersimulation und Rotary-Simulation)&lt;br /&gt;
** Zusätzliche Ausgangssignale und Effektschleifen-Eingang über 16-polige Stiftleiste &#039;&#039;&#039;PL2&#039;&#039;&#039; und 3-polige Wire-to-Board-Anschlüsse verfügbar&lt;br /&gt;
** JackExtension PCB für zusätzliche MIDI- und Audio-Eingangs-/Ausgangsbuchsen erhältlich, gleiche Buchsenposition wie die alte Erweiterungsplatine&lt;br /&gt;
&lt;br /&gt;
=== Technische Daten ===&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Größe:&#039;&#039;&#039; 200 x 100 mm&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Stromversorgung:&#039;&#039;&#039; 5V/400mA or 9-12V/300mA (ohne Peripherie)&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Klangerzeugung:&#039;&#039;&#039; HX3 mk6 Sound Engine, Hardware-Emulation (Physical Modeling) durch FPGA der 7. Generation. Je 61 Töne auf Ober-/Untermanual ebenso wie Pedal. 15 Harmonische pro Taste, Hammond-typische Perkussion auf allen Harmonischen. Tastung auf allen Fußlagen wählbar zwischen &amp;quot;mechanisch&amp;quot; (Hammond-typische Tastenkontakte) oder elektronisch (LSI/Transistororgeln). Die  elektronische Tastung nutzt separate Hüllkurven (ADSR) für jede Fußlage und jede Taste (915 ADSR/VCA-Schaltkreise pro Manual).&lt;br /&gt;
&lt;br /&gt;
Quadcore-DSP mit 64 MByte Sample-Speicher für Hall/EFX und 128 General-MIDI-Stimmen (GM2), 81-fach polyphon. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschlüsse:&#039;&#039;&#039; 6,3mm-Buchse für Fußschalter, 6,3mm-Buchse für Schwellerpedal (Yamaha FC-7 oder ähnlich), DIN-5-pol. MIDI IN, MIDI IN/OUT, DC-Buchse für 5V- oder 9V-Steckernetzteil min. 500mA, 6,3mm-Buchsen für  Stereo-Audioausgang. USB-B-Buchse (bei Bedarf einzulöten). Anschlüsse auf dem Board für Stromversorgung 5V und 9...12V, I2C Bussystem für Menüpanel und Anschluss von Preset-Boards (kompatibel mit unseren Preset12-2- und Preset16-Boards), MPX-Bus für analoge Steuereingänge.&lt;br /&gt;
&lt;br /&gt;
== Dokumente, Updates und Anleitungen ==&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.7 Installationsanleitung]]&#039;&#039;&#039; Mainboard Hardware-Installation für HX3.7&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[MPX Bus (deutsch)]]&#039;&#039;&#039; Verwendung von MPX-Baugruppen (analoge Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[I2C Bus (deutsch)]]&#039;&#039;&#039; Verwendung von I2C-Baugruppen (digitale Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[Scan Boards (deutsch)]]&#039;&#039;&#039; Verwendung von Keyboard-Scan-Platinen&lt;br /&gt;
* &#039;&#039;&#039;[[Legacy Board (deutsch)]]&#039;&#039;&#039; Verwendung des Legacy Boards zur Weiterverwendung vorhandener Hardware&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Backgrounder (deutsch)]]&#039;&#039;&#039; Grundlegende Informationen über HX3 Sound Engine ab Version 3.5 resp. Böhm RealOrgan&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Migration Guide (deutsch)]]&#039;&#039;&#039; Wichtige Hinweise für den Umstieg von HX3.5 auf HX3.6 oder HX3.7&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 First Aid (deutsch)]]&#039;&#039;&#039; Update oder Einbau eines neuen Boards arbeiten fehlerhaft? Zuerst hier lesen!&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3 MIDI-Implementierung]]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Sweep Generator]]&#039;&#039;&#039; Verwendung des eigebauten Sweep-Generators zur Frequenzganganalyse (ab HX3.6, vorläufig)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Bootloader Update (deutsch)]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über USB/DFU&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6/3.7 Verwendung von SD-Karten]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über SD-Karte, Verwendung der INI-Skripte&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/ HX3 Update Page]&#039;&#039;&#039; Aktuelle Updates, Anleitungen/Handbücher, Zeichnungen und Tools&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Mainboard.pdf HX3.6 Mainboard Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_MIDI_Expander.pdf HX3.6 MIDI Expander Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Manager.pdf HX3.6 Manager Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039; für Parametereinstellung, Updates und Finalisierung&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/WiFi_Modul_Einbauanleitung.pdf HX3.5/HX3.6 WiFi Interface, nachträgliche Installation]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 HX3 Schaltbilder]&#039;&#039;&#039;, vollständige Schaltbilder für alle Boards&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/HX3.7%20XB2%20Kit%20Installationsanleitung.pdf Einbauanleitung XB2-Kit]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung%20HX37_XB2.pdf Bedienungsanleitung XB2-Kit]&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_Main_page&amp;diff=7021</id>
		<title>HX3.6 Main page</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_Main_page&amp;diff=7021"/>
		<updated>2025-12-11T15:59:35Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Documents, Updates &amp;amp; Manuals */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx36_mainboard_slant.JPG|400px|thumb|right|&#039;&#039;&#039;HX3 mk5 mainboard&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
== Preface ==&lt;br /&gt;
&lt;br /&gt;
=== Features ===&lt;br /&gt;
&lt;br /&gt;
HX3.6 (HX3 mk6) is the follow-up model of the well-known HX3 mk5 board. While maintaining size and form factor, it offers higher performance and more flexibilty by using a larger 7th generation XILINX FPGA and a more powerful ARM microcontroller that handles the user interface. &lt;br /&gt;
&lt;br /&gt;
As an option (extended licence required), the new HX3 engine is capable of emulating all electromagnetic organs including H100, combo organs, several concert organs of the 70s and 80s like Böhm Orchester and Wersi Helios. This implies up to 15 harmonics, up to 12 drawbars per manual with individual mixtures, including phasing rotor (WersiVoice), mechanical and electronic keying available simultaneously. ADSR envelope available on all drawbars, also H100 percussion and &amp;quot;Harp Sustain&amp;quot;. New tone generator switchable from tonewheel to TOS (top octave synthesizer) or single note mode, loadable generator waveforms for &amp;quot;cheesy&amp;quot; combo organs as well as fully fledged concert organs.&lt;br /&gt;
&lt;br /&gt;
In many respects, HX3.6 is compatible with the older HX3.5 board (most peripherals, header pinout, mechanical dimensions). However, there are additional connectors, also the connector lettering has changed. An Editor application (part of the HX3.6 Manager application) provides access to the vastly increased HX3.6 parameter count.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;HX3.6 components are meant to be installed by a skilled technician. Basic IT knowledge is mandatory since software has to be installed and configurated in some cases.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Technical Data ===&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Size:&#039;&#039;&#039; 200 x 100 mm&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Power Supply:&#039;&#039;&#039; 5V/400mA or 9-12V/300mA (without peripherals)&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Sound generation:&#039;&#039;&#039; HX3 mk6 Sound Engine, hardware emulation (physical modeling) by 7th generation FPGA. 61 keys on upper/lower manual as well as pedal. 15 harmonics per key, Hammond-type percussion on all harmonics. Keying of each harmonic selectable to &amp;quot;mechanical&amp;quot; (Hammond-type key contacts) or electronic gating (LSI/transistor organs). Electronic gating uses separate ADSR circuit for each harmonic and each key (915 ADSR/VCA circuits per manual). &lt;br /&gt;
&lt;br /&gt;
Quad core DSP with 64 MByte sample memory for reverb/efx and 128 GM2 voices. 81-note polyphony. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Connections:&#039;&#039;&#039; 1/4&amp;quot; jack footswitch, 1/4&amp;quot; jack Swell pedal  (Yamaha FC-7 or similar), DIN-5pin MIDI IN, MIDI IN/OUT, DC jack 5V or 9V wallwart power supply min. 500mA, 1/4&amp;quot; jacks for stereo audio output, USB MIDI jack (must be soldered in place if needed). Connectors for up to 24 drawbars/pots on board (extendable to 64 drawbars/pots), 16 buttons (extendable to 64 buttons), 6-position Vibrato rotary switch, I2C bus system for MenuPanel and Preset board connection (compatible to our Preset12-2 and Preset16 boards).&lt;br /&gt;
&lt;br /&gt;
== Documents, Updates &amp;amp; Manuals ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Installation Manual]]&#039;&#039;&#039; Mainboard hardware installation&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[MPX Bus]]&#039;&#039;&#039; Detailed informations to MPX analog input boards&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[I2C Bus]]&#039;&#039;&#039; Detailed informations to I2C digital input boards&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[Scan Boards]]&#039;&#039;&#039; Detailed informations to keybed scan boards&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Backgrounder]]&#039;&#039;&#039; In-depth information about HX3 mk5 resp. Böhm RealOrgan Sound Engine&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Migration Guide (english)]]&#039;&#039;&#039; Hints for migration from HX3.5 to HX3.6 or HX3.7&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 First Aid (english)]]&#039;&#039;&#039; Update or installation of a new board failed? Read this first!&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[How to address unwanted distortions (english)]]&#039;&#039;&#039; Fixing clipping noises and rotary sim artefacts for picky players&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Extension Board]]&#039;&#039;&#039; Installation for HX3.6 boards&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[Using HX3 with MIDI controllers]]&#039;&#039;&#039; - HX3 MIDI implementation charts for all MIDI CC sets&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Sweep Generator (english)]]&#039;&#039;&#039; Using the built-in Sweep Generators for frequency response analysis (HX3.6 and up, preliminary)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Bootloader Update (english)]]&#039;&#039;&#039; Update of Firmware and Sound Engine via USB&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6/3.7 SD Card Usage]]&#039;&#039;&#039; Updating Controller firmware and FPGA sound engine using SD card adaptor&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de HX3 Update Page]&#039;&#039;&#039; Most recent updates, manuals, drawings and tools&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_Mainboard.pdf HX3.6 Mainboard User Manual, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_MIDI_Expander.pdf HX3.5 MIDI Expander User Manual, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_MIDI_Expander_Extended.pdf HX3.6 MIDI Expander with extended license User Manual, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_Manager.pdf HX3.6 Manager User Manual, printable PDF file]&#039;&#039;&#039; for altering parameters, update transfers and finalizing&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/WiFi_Module_Installation_Guide.pdf HX3.5/HX3.6 WiFi interface installation guide, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 HX3 Schematics repository]&#039;&#039;&#039;, complete schematics for all boards&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/index.php?dir=Manuals%20%28Anleitungen%29/Older%20products Older products Manuals (PDFs), XB2 Kit and others]&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.7_Main_page&amp;diff=7020</id>
		<title>HX3.7 Main page</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.7_Main_page&amp;diff=7020"/>
		<updated>2025-12-11T15:59:10Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Documents, Updates &amp;amp; Manuals */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx37_mb_slant_2k.JPG|600px|thumb|right|HX3.7 Mainboard]]&lt;br /&gt;
&lt;br /&gt;
== Preface==&lt;br /&gt;
&lt;br /&gt;
HX3.7 (HX3 mk7) is the follow-up model of the well-known HX3 mk5 and mk6 boards. While maintaining size and form factor, it offers higher performance and more flexibilty by using a larger 7th generation XILINX FPGA and a more powerful ARM microcontroller that handles the user interface. &lt;br /&gt;
&lt;br /&gt;
As an option (extended licence required), the new HX3 engine is capable of emulating all electromagnetic organs including H100, combo organs, several concert organs of the 70s and 80s like Böhm Orchester and Wersi Helios. This implies up to 15 harmonics, up to 12 drawbars per manual with individual mixtures, including phasing rotor (WersiVoice), mechanical and electronic keying available simultaneously. ADSR envelope available on all drawbars, also H100 percussion and &amp;quot;Harp Sustain&amp;quot;. New tone generator switchable from tonewheel to TOS (top octave synthesizer) or single note mode, loadable generator waveforms for &amp;quot;cheesy&amp;quot; combo organs as well as fully fledged concert organs.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;HX3.7 components are meant to be installed by a skilled technician. Basic IT knowledge is mandatory since software has to be installed and configurated in some cases.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
== Features ==&lt;br /&gt;
&lt;br /&gt;
The improved, highly integrated HX3.7 mainboard replaces the older HX3.6 mainboard and should be compatible with most existing installations. The basic HX3.7 board offers 2 audio output channels like HX3.6, while the &#039;&#039;&#039;HX3.7 EFX&#039;&#039;&#039; version offers 4 channel DACs, full Leslie speaker control circuits and an effects insert loop with additional ADC between internal tube amp and internal rotary simulation. This allows separate use of the rotary simulation for external musical instruments as well. Basic HX3.7 boards may be upgraded to HX3.7 EFX by factory.&lt;br /&gt;
&lt;br /&gt;
HX3.7 does no longer offer &amp;quot;legacy&amp;quot; button/switch inputs (like &#039;&#039;&#039;Panel16&#039;&#039;&#039;) and classic analog drawbar inputs (old green &#039;&#039;&#039;DB9/DB12&#039;&#039;&#039; boards). Instead, it relies on I2C bus interfaces on external panels (like Preset16, Extern16 or VibratoSwitch) and analog scanning MPX bus circuits as found on PTX, ANX, DBX9 and DBX12 drawbar boards. For existing OEM installations, we will offer an interface (&#039;&#039;&#039;LegacyBoard&#039;&#039;&#039;) providing connectors for legacy hardware. However, we &#039;&#039;&#039;strongly recommend&#039;&#039;&#039; I2C bus (&#039;&#039;&#039;PANEL I2C&#039;&#039;&#039; connector, for buttons/switches/LEDs) and MPX bus (&#039;&#039;&#039;ANLG MPX&#039;&#039;&#039;, analog scanning for pots/drawbars) circuitry as this greatly reduces wiring effort.&lt;br /&gt;
&lt;br /&gt;
===Common Features with HX3.5/HX3.6===&lt;br /&gt;
&lt;br /&gt;
* Same HX3 Manager, firmware and FPGA sound engine&lt;br /&gt;
* Same PCB size, same mounting holes&lt;br /&gt;
* Same location of DC, USB, audio and MIDI connectors&lt;br /&gt;
* MenuPanel/Preset Bus Connector (I2C)&lt;br /&gt;
* Analog MPX Bus for newer DBX, PTX and ANX boards&lt;br /&gt;
* Auxiliary MIDI out, Fatar scan and pedal scan connectors&lt;br /&gt;
* Digital signal processor (DSP) for reverb, GM voices and USB handling&lt;br /&gt;
&lt;br /&gt;
===Omitted Features===&lt;br /&gt;
&lt;br /&gt;
* No onboard drawbar inputs&lt;br /&gt;
* No onboard button/switch inputs&lt;br /&gt;
* No ExtensionBoard connector (Leslie control and headphone amp circuit integrated on board now)&lt;br /&gt;
&lt;br /&gt;
===Additional Features===&lt;br /&gt;
&lt;br /&gt;
* Stereo Headphone amp&lt;br /&gt;
* Improved DACs and audio amps/filters&lt;br /&gt;
* 3 onboard MIDI connectors (2x IN, 1x OUT), MIDI OUT may alternatively be mounted on JackExtension&lt;br /&gt;
* Onboard audio output jacks may be jumpered as L/R mono jacks &#039;&#039;&#039;or&#039;&#039;&#039; stereo L/R and stereo headphone jack&lt;br /&gt;
* Features integrated with enhanced &#039;&#039;&#039;HX3.7 EFX&#039;&#039;&#039; version:&lt;br /&gt;
** Integrated 11-pin Leslie™ control, ExtensionBoard pinout on 14-pin box header &#039;&#039;&#039;PL1&#039;&#039;&#039;&lt;br /&gt;
** Additional DAC (outputs for plain organ and pedal signal), total of 4 audio output channels&lt;br /&gt;
** Insert loop (mono effects insert between tube amp simulation and rotary simulation)&lt;br /&gt;
** Additional output signals and effect loop input available on 16-pin box header &#039;&#039;&#039;PL2&#039;&#039;&#039; and 3-pin wire-to-board connectors&lt;br /&gt;
** JackExtension PCB available for additional MIDI and audio input/output jacks, same jack location as old extension board&lt;br /&gt;
&lt;br /&gt;
=== Technical Data ===&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Size:&#039;&#039;&#039; 200 x 100 mm&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Power Supply:&#039;&#039;&#039; 5V/400mA or 9-12V/300mA (without peripherals)&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Sound generation:&#039;&#039;&#039; HX3 mk7 Sound Engine, hardware emulation (physical modeling) by 7th generation FPGA. 61 keys on upper/lower manual as well as pedal. 15 harmonics per key, Hammond-type percussion on all harmonics. Keying of each harmonic selectable to &amp;quot;mechanical&amp;quot; (Hammond-type key contacts) or electronic gating (LSI/transistor organs). Electronic gating uses separate ADSR circuit for each harmonic and each key (915 ADSR/VCA circuits per manual). &lt;br /&gt;
&lt;br /&gt;
Quad core DSP with 64 MByte sample memory for reverb/efx and 128 GM2 voices. 81-note polyphony. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Connections:&#039;&#039;&#039; 1/4&amp;quot; jack footswitch, 1/4&amp;quot; jack Swell pedal  (Yamaha FC-7 or similar), DIN-5pin MIDI IN, MIDI IN2, DC jack 5V or 9V wallwart power supply min. 500mA, 1/4&amp;quot; jacks for stereo audio output or headphone, USB MIDI jack (must be soldered in place if needed). I2C bus system for MenuPanel and Preset board connection (compatible to our Preset12-2 and Preset16 boards), MPX bus system for analog controllers. HX3.7 EFX version features effect loop insert and separate DAC for external Leslie™ control (integrated &#039;&#039;&#039;ExtensionBoard&#039;&#039;&#039;).&lt;br /&gt;
&lt;br /&gt;
== Documents, Updates &amp;amp; Manuals ==&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.7 Installation Manual]]&#039;&#039;&#039; Preliminary installation manual for new &#039;&#039;&#039;HX3.7&#039;&#039;&#039; Mainboard&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[MPX Bus]]&#039;&#039;&#039; Detailed informations to MPX analog input boards&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[I2C Bus]]&#039;&#039;&#039; Detailed informations to I2C digital input boards&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[Scan Boards]]&#039;&#039;&#039; Detailed informations to keybed scan boards&lt;br /&gt;
* &#039;&#039;&#039;[[Legacy Board]]&#039;&#039;&#039; Using the Legacy Board for existing/obsolete hardware&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Backgrounder]]&#039;&#039;&#039; In-depth information about HX3 Sound Engine resp. Böhm RealOrgan, applicable to HX3.5/3.6/3.7&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Migration Guide (english)]]&#039;&#039;&#039; Hints for migration from HX3.5 to HX3.6 or HX3.7&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 First Aid (english)]]&#039;&#039;&#039; Update or installation of a new board failed? Read this first!&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[Using HX3 with MIDI controllers]]&#039;&#039;&#039; - HX3 MIDI implementation charts for all MIDI CC sets&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[How to address unwanted distortions (english)]]&#039;&#039;&#039; Fixing clipping noises and rotary sim artefacts for picky players&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Sweep Generator (english)]]&#039;&#039;&#039; Using the built-in Sweep Generators for frequency response analysis (HX3.6 and up, preliminary)&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Bootloader Update (english)]]&#039;&#039;&#039; Update of Firmware and Sound Engine via USB or SD card&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6/3.7 SD Card Usage]]&#039;&#039;&#039; Updating Controller firmware and FPGA sound engine using SD card adaptor&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de HX3 Update Page]&#039;&#039;&#039; Most recent updates, manuals, drawings and tools&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_Mainboard.pdf HX3.6 Mainboard User Manual, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_MIDI_Expander_Extended.pdf HX3.6 MIDI Expander with extended license User Manual, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/UserManual_HX36_Manager.pdf HX3 Manager User Manual, printable PDF file]&#039;&#039;&#039; for altering parameters, update transfers and finalizing&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/WiFi_Module_Installation_Guide.pdf HX3.5/HX3.6/HX3.7 WiFi interface installation guide, printable PDF file]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 HX3 Schematics repository]&#039;&#039;&#039;, complete schematics for all boards&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/HX3.7%20XB2%20Kit%20Installation%20Guide.pdf Installation Manual XB2-Kit]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/User%20Manual%20HX37_XB2.pdf User Manual XB2-Kit]&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3.6_Hauptseite_(deutsch)&amp;diff=7019</id>
		<title>HX3.6 Hauptseite (deutsch)</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3.6_Hauptseite_(deutsch)&amp;diff=7019"/>
		<updated>2025-12-11T15:57:38Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Dokumente, Updates und Anleitungen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx36_mainboard_slant.JPG|400px|thumb|right|&#039;&#039;&#039;HX3 mk5 mainboard&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
=== Features ===&lt;br /&gt;
&lt;br /&gt;
HX3.6 (HX3 mk6) ist das Nachfolgemodell des bekannten HX3 mk5 Boards. Bei gleicher Größe und Form bietet es höhere Performance und mehr Flexibilität aufgrund der Ausstattung mit einem größeren XILINX FPGA-Chip der 7. Generation und einem deutlich leistungsfähigeren ARM-Controller für die Abfrage der Bedienelemente.&lt;br /&gt;
&lt;br /&gt;
Optional (mit Extended Licence) ist der neue HX3 TrueOrgan Klanggenerator imstande, alle elektromagnetischen Orgeln nachzubilden, inklusive der berühmten H100, dazu Combo-Orgeln und Konzertorgeln der 70er und 80er Jahre wie Böhm Orchester und Wersi Helios. Er erzeugt bis zu 15 Fußlagen und ermöglicht bis zu 12 Zugriegel pro Manual mit individuellen Mixturen, inklusive Phasing-Vibrato (WersiVoice, Böhm Phasing Rotor). Mechanische und elektronische Tastung können simultan genutzt werden. Auf allen Zugriegeln sind ADSR-Hüllkurven verfügbar, außerdem H100-Perkussion sowie „Harp Sustain“. Diverse Tongenerator-Wellenformen stehen zur Auswahl, für „käsige“ Combo-Orgeln ebenso wie für die klangstarken Konzertorgeln.&lt;br /&gt;
&lt;br /&gt;
In vielen Details ist HX3.6 kompatibel mit dem älteren HX3.5 Board (die meisten Peripherie-Anschlüsse, Pinout der Steckverbinder, mechanische Dimensionen). Allerdings gibt es zusätzliche Anschlüsse und die Nummerierung hat sich geändert. Der Editor im HX3.6-Manager verschafft Zugang zu den Parametern, deren Zahl drastisch gewachsen ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Die HX3.6-Komponenten sind zur Installation durch erfahrene Techniker gedacht. PC-Kentnisse werden vorausgesetzt, da eventuell Software-Bestandteile installiert und konfiguriert werden müssen.&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
=== Technische Daten ===&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Größe:&#039;&#039;&#039; 200 x 100 mm&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Stromversorgung:&#039;&#039;&#039; 5V/400mA or 9-12V/300mA (ohne Peripherie)&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Klangerzeugung:&#039;&#039;&#039; HX3 mk6 Sound Engine, Hardware-Emulation (Physical Modeling) durch FPGA der 7. Generation. Je 61 Töne auf Ober-/Untermanual ebenso wie Pedal. 15 Harmonische pro Taste, Hammond-typische Perkussion auf allen Harmonischen. Tastung auf allen Fußlagen wählbar zwischen &amp;quot;mechanisch&amp;quot; (Hammond-typische Tastenkontakte) oder elektronisch (LSI/Transistororgeln). Die  elektronische Tastung nutzt separate Hüllkurven (ADSR) für jede Fußlage und jede Taste (915 ADSR/VCA-Schaltkreise pro Manual).&lt;br /&gt;
&lt;br /&gt;
Quadcore-DSP mit 64 MByte Sample-Speicher für Hall/EFX und 128 General-MIDI-Stimmen (GM2), 81-fach polyphon. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Anschlüsse:&#039;&#039;&#039; 6,3mm-Buchse für Fußschalter, 6,3mm-Buchse für Schwellerpedal (Yamaha FC-7 oder ähnlich), DIN-5-pol. MIDI IN, MIDI IN/OUT, DC-Buchse für 5V- oder 9V-Steckernetzteil min. 500mA, 6,3mm-Buchsen für  Stereo-Audioausgang. USB-B-Buchse (bei Bedarf einzulöten). Anschlüsse auf dem Board für Stromversorgung 5V und 9...12V, bis zu 24 Zugriegel/Potentiometer (erweiterbar auf bis zu 88 Zugriegel/Potentiometer), 16 Taster (erweiterbar auf bis zu 64 Taster), 6-fach Vibrato-Drehschalter, I2C Bussystem für Menüpanel und Anschluss von Preset-Boards (kompatibel mit unseren Preset12-2- und Preset16-Boards).&lt;br /&gt;
&lt;br /&gt;
== Dokumente, Updates und Anleitungen ==&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Installationsanleitung]]&#039;&#039;&#039; Mainboard Hardware-Installation&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[MPX Bus (deutsch)]]&#039;&#039;&#039; Verwendung von MPX-Baugruppen (analoge Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[I2C Bus (deutsch)]]&#039;&#039;&#039; Verwendung von I2C-Baugruppen (digitale Eingänge)&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[Scan Boards (deutsch)]]&#039;&#039;&#039; Verwendung von Keyboard-Scan-Platinen&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Backgrounder (deutsch)]]&#039;&#039;&#039; Grundlegende Informationen über HX3 Sound Engine ab Version 3.5 resp. Böhm RealOrgan&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 Migration Guide (deutsch)]]&#039;&#039;&#039; Wichtige Hinweise für den Umstieg von HX3.5 auf HX3.6&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6 First Aid (deutsch)]]&#039;&#039;&#039; Update oder Einbau eines neuen Boards arbeiten fehlerhaft? Zuerst hier lesen!&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3.5 Extension Board (deutsch)]]&#039;&#039;&#039; Installation, auch gültig für HX3.6&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3 MIDI-Implementierung]]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Sweep Generator]]&#039;&#039;&#039; Verwendung des eigebauten Sweep-Generators zur Frequenzganganalyse (ab HX3.6, vorläufig)&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3 Bootloader Update (deutsch)]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über USB&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[[HX3.6/3.7 Verwendung von SD-Karten]]&#039;&#039;&#039; Updaten der Firmware und Sound Engine über SD-Karte, Verwendung der INI-Skripte&amp;lt;br&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/ HX3 Update Page]&#039;&#039;&#039; Aktuelle Updates, Anleitungen/Handbücher, Zeichnungen und Tools&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Mainboard.pdf HX3.6 Mainboard Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_MIDI_Expander.pdf HX3.6 MIDI Expander Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039;&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/Bedienungsanleitung_HX36_Manager.pdf HX3.6 Manager Bedienungsanleitung als druckbares PDF]&#039;&#039;&#039; für Parametereinstellung, Updates und Finalisierung&amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/Manuals%20%28Anleitungen%29/WiFi_Modul_Einbauanleitung.pdf HX3.5/HX3.6 WiFi Interface, nachträgliche Installation]&#039;&#039;&#039; &amp;lt;br&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/?dir=Schematics%20%28Schaltbilder%29 HX3 Schaltbilder]&#039;&#039;&#039;, vollständige Schaltbilder für alle Boards&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;[http://updates.keyboardpartner.de/Files/index.php?dir=Manuals%20%28Anleitungen%29/Older%20products Manuals für ältere Produkte (PDFs), XB2 Kit und andere]&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7018</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7018"/>
		<updated>2025-12-11T15:56:44Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorwort */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #11122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7017</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7017"/>
		<updated>2025-12-07T15:03:38Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #04122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. Schließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7016</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7016"/>
		<updated>2025-12-07T15:01:22Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorwort */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #04122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in die offizielle Manager-Version übernommen. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7015</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7015"/>
		<updated>2025-12-07T15:00:37Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorwort */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #04122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in der offiziellen Manager-Version eingebaut. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7014</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7014"/>
		<updated>2025-12-06T13:09:15Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #05122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in der offiziellen Manager-Version eingebaut. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Pegel-Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7013</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7013"/>
		<updated>2025-12-06T13:08:39Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Vorwort */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #05122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Diese Funktion war anfangs nur für Entwicklungszwecke gedacht, wir haben sie nun aber auch in der offiziellen Manager-Version eingebaut. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der Sweep-Tab wie im nebenstehenden Bild im HX3-Manager aktiv ist. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7012</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7012"/>
		<updated>2025-12-06T13:04:48Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* EFX-Eingang nutzen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #05122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der nebenstehende Tab im HX3-Manager aktiv ist. Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|400px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=Datei:SweepAnalyzer.png&amp;diff=7011</id>
		<title>Datei:SweepAnalyzer.png</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=Datei:SweepAnalyzer.png&amp;diff=7011"/>
		<updated>2025-12-06T13:03:59Z</updated>

		<summary type="html">&lt;p&gt;Bovist: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
	<entry>
		<id>https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7010</id>
		<title>HX3 Sweep Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.keyboardpartner.de/index.php?title=HX3_Sweep_Generator&amp;diff=7010"/>
		<updated>2025-12-06T13:03:09Z</updated>

		<summary type="html">&lt;p&gt;Bovist: /* Lizenz einrichten */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Datei:Hx3_sweepgen.png|800px|thumb|right|&#039;&#039;&#039;&lt;br /&gt;
Sweep-Generator-Tab des HX3 Manager 7.20&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Vorwort==&lt;br /&gt;
&lt;br /&gt;
Ab der Sound-Engine-Version #05122025 (FPGA) und Firmware 7.060 ist ein &#039;&#039;&#039;Sinus-Testgenerator&#039;&#039;&#039; in HX3 eingebaut, der zum Überprüfen von Schweller-Einstellungen (Bereich, Loudness, AO28-Frequenzgang), des Vibratos, Phasing Rotors und externer Effektgeräte dient. Es ist sogar möglich, den Frequenzgang einer historischen Orgel zu überprüfen, indem der Effektgeräte-Eingang auf das Messsignal geschaltet wird (siehe unten). Der interne Sinusgenerator mit durchstimmbarer Frequenz wird intern vor PHR- und Vibrato-Effekten eingespeist, wenn der nebenstehende Tab im HX3-Manager aktiv ist. Schalten Sie für erste Messungen Hall, Vibrato und Phasing Rotor ab und den internen Equalizer auf &amp;quot;Bypass&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Nach Anwählen des Tabs &amp;quot;Swell Sweep&amp;quot; wird ein recht lauter Messton höbar. Das Verlassen des Tabs schaltet ihn wieder ab.&lt;br /&gt;
&lt;br /&gt;
===Laden von Mess- und Referenzkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Load&amp;quot; und wählen Sie eine der mitgelieferten &amp;quot;sweep_xxx.csv&amp;quot;-Dateien im User-Verzeichnis aus. Dies füllt die Messwerte-Tabelle unten und stellt eine Kurvenschar gedimmt dar.&lt;br /&gt;
&lt;br /&gt;
===Speichern von Messkurven===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Save&amp;quot;. Die Tabelle wird als CSV-Datei (Text, in Excel importierbar) gespeichert.&lt;br /&gt;
&lt;br /&gt;
===Neue Messung anlegen===&lt;br /&gt;
&lt;br /&gt;
Eine neue Messung nutzt stets die in der Spalte &amp;quot;Freq Hz&amp;quot; vorgegebenen Frequenzen, es können also auch eigene Frequenzverläufe erstellt oder die einer vorhandenen Messreihe genutzt werden. Sie legen eine neue Tabelle mit einem Klick auf &amp;quot;Sweep New&amp;quot; an. Die Anzahl der Messpunkte (Tabellen-Reihen) ist abhängig von dem nebenstehenden Dropdown-Menü. Besonders schnelle, eher grobe Messungen erzielen Sie mit der Einstellung &amp;quot;Short&amp;quot;, die Auswahl &amp;quot;Fine&amp;quot; erzeugt dagegen eine deutlich feinere Frequenzauflösung. Die Tabelle wird algorithmisch erzeugt, Sie können aber einzelne Werte in der Frequenztabelle nach Belieben ändern (und abspeichern).&lt;br /&gt;
&lt;br /&gt;
==Sweeps==&lt;br /&gt;
&lt;br /&gt;
Frequenz-Sweeps ermitteln den Amplitudenverlauf von Audio-Elektronik bei unterschiedlichen Frequenzen. Der Frequenzgang ist besonders bei der Preamp-Simulation für den Klangeindruck entscheidend. Bei den meisten elektromagnetischen Orgeln ist ab etwa 250 Hz ein mäßig starker Abfall hin zu höheren Frequenzen festzustellen; dies wird sowohl vom Preamp als auch von den Anpassungstransformatoren (Drawbar Mathching Transformer) verursacht und ist durchaus erwünscht. &lt;br /&gt;
&lt;br /&gt;
Für Sweeps und Auto-Sweeps ist eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!), siehe hierzu auch [[#Lizenz einrichten]]. &lt;br /&gt;
&lt;br /&gt;
===Messen des Schweller-Frequenzgangs der Preamp-Simulation===&lt;br /&gt;
&lt;br /&gt;
Wählen Sie mit dem Dropdown-Menü oben links den Eingang &amp;quot;Preamp out&amp;quot;. Der Balken &amp;quot;Level Detect&amp;quot; sollte nun einen von der Schwellerstellung abhängigen Pegel anzeigen. Sie verändern Pegel und Frequenz des Testsignals (Sinus) mit den Trackbars &amp;quot;Test Generator Level&amp;quot; und &amp;quot;Test Generator Frequency&amp;quot;. Stellen Sie bei vollem Schweller eine Frequenz von 225 Hz ein und justieren Sie &amp;quot;Test Generator Level&amp;quot; so, dass ein &amp;quot;Level Detect&amp;quot; von etwa -10dB angezeigt wird. Beim durchstimmen des Testgenerators wird sich der Pegel leicht verändern.&lt;br /&gt;
&lt;br /&gt;
===Einzelnen Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Klicken Sie auf &amp;quot;Sweep Single&amp;quot;. Der Testgenerator erzeugt eine Reihe von Frequenzen anhand der Tabelle, listet die gemessenen Werte in der Tabelle auf und zeigt die ermittelte Messkurve in der Grafik an. Jeder neue Klick auf &amp;quot;Sweep Single&amp;quot; erzeugt eine weitere Messreihe (bis zu 8 &amp;quot;Runs&amp;quot;), so dass der Vergleich unterschiedlicher Preamp-Parameter oder unterschiedlicher Schweller-Stellungen unmittelbar möglich ist. Ohnehin wird die gedimmte Darstellung einer vorher &#039;&#039;geladenen&#039;&#039;, gedimmt dargestellten Messreihe in der Grafik nicht überschrieben (erst bei einem Klick auf &amp;quot;New&amp;quot;).&lt;br /&gt;
&lt;br /&gt;
===Auto-Sweep durchführen===&lt;br /&gt;
&lt;br /&gt;
Diese Funktion dient zur Überprüfung des Frequenzgangs bei unterschiedlichen Schweller-Stellungen (0%, 5%, 10%, 15%, 25%, 50%, 75%, 100%), wichtig für die Loudness-Korrektur des AO28-Preamps. Es werden 8 &amp;quot;Runs&amp;quot; ausgeführt, jeweils mit unterschiedlicher Schweller-Stellung (Parameter #1600). Es ergibt sich eine Kurvenschar wie im Bild oben zu sehen. Klicken sie hierfür auf &amp;quot;Sweep Auto&amp;quot;. Der Vorgang kann jederzeit mit einem Klick auf &amp;quot;Stop&amp;quot; abgebrochen werden.&lt;br /&gt;
&lt;br /&gt;
===Schweller-Einstellungen in HX3 speichern===&lt;br /&gt;
&lt;br /&gt;
Im Unterschied zu früheren Firmware-Versionen wird nun keine fest vorgegebene Schweller-Loudness-Kurve (Editor-Parameter #1384, jetzt obsolet) mehr verwendet. Stattdessen ist für jedes Orgelmodell ein individuelles Schweller-Verhalten mit den neuen Parametern #1091 bis #1095 (unter &#039;&#039;Volume Pots&#039;&#039; zu finden) einstellbar, ähnlich wie vorher schon für die Trim-Cap- und Minimal-Swell-Einstellungen.&lt;br /&gt;
&lt;br /&gt;
Wenn Sie eine zufriedenstellende Einstellung gefunden haben, können Sie diese mit &amp;quot;Store to Organ&amp;quot; auf dem HX3-Board speichern. Button und Auswahl der Orgelmodelle mit dem Dropdown-Menü haben die gleiche Funktion wie die gleichnamigen Bedienelemente im Tab &amp;quot;Organs&amp;quot; und sind nur der Bequemlichkeit halber hier nochmals vorhanden, so dass man Orgelmodelle schnell vergleichen kann.&lt;br /&gt;
&lt;br /&gt;
==EFX-Eingang nutzen==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep_equalizer.png|600px|thumb|right|&#039;&#039;&#039;Sweep-Generator misst den internen HX3-Equalizer mit verschiedenen (teilweise unsinnigen) Einstellungen&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Unter Verwendung des Effektschleifen-Eingangs &amp;quot;EFX Input&amp;quot; (nur bei HX3.7) ist auch die Messung von externen Geräten und des HX3-Equalizers möglich. Ist die Checkbox &amp;quot;Measure External FX Loop&amp;quot; aktiv, wird der Pegeldetektor auf den Effektschleifen-Eingang des HX3 gelegt, das unveränderte Signal des Testgenerators erscheint am Orgel-Ausgang. Die interne Preamp-Simulation ist hierbei &#039;&#039;&#039;abgeschaltet&#039;&#039;&#039;, der Frequenzgang ist somit vollkommen linear.&lt;br /&gt;
&lt;br /&gt;
===Externe Geräte messen===&lt;br /&gt;
&lt;br /&gt;
Zum Test verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen &#039;&#039;&#039;geradlinigen Frequenzgang&#039;&#039;&#039; erzeugen.&lt;br /&gt;
&lt;br /&gt;
Sie können mit dieser Konfiguration zum Beispiel den Frequenzgang eines Effektgerätes messen, das zwischen &amp;quot;Organ&amp;quot; und &amp;quot;EFX Input&amp;quot; eingeschleift ist. Die Profis können sogar den Frequenzgang ihrer hirstorischen Orgel messen; das Ausgangssignal an &amp;quot;Organ&amp;quot; wird dafür über einen Widerstand von 1 kOhm an eine der mittleren Preset-Sammelschienen der Orgel zugeführt und an &#039;&#039;&#039;einem&#039;&#039;&#039; der G-G-Ausgänge und Masse wieder abgenommen. Beachten Sie, dass der Ausgangspegel am G-Anschluss sehr hoch ist, der EFX-Pegelsteller ist daher nach links zu drehen.&lt;br /&gt;
&lt;br /&gt;
===HX3-Equalizer messen===&lt;br /&gt;
&lt;br /&gt;
Der interne Equalizer des HX3-DSP ist wegen der parametrischen Struktur möglicherweise schwierig einzustellen, insbesondere, was Güte (Peak) und genaue Frequenz betrifft. Mit einem Sweep werden kritische Einstellungen deutlich vereinfacht.&lt;br /&gt;
&lt;br /&gt;
Verbinden Sie den Ausgang &amp;quot;Organ&amp;quot; über ein Klinkenkabel direkt mit &amp;quot;EFX Input&amp;quot; und stellen den Effekt-Pegelsteller auf Rechtsanschlag. Ein Sweep sollte nun einen geradlinigen Frequenzgang erzeugen. Schalten Sie nun den Equalizer-Bypass auf &amp;quot;Off&amp;quot; und spielen Sie mit den Equalizer-EInstellungen (am Gerät oder über das Panel des HX3-Managers). Es ergeben sich Kurvenverläufe, die die Equalizer-Einstellung deutlich sichtbar machen.&lt;br /&gt;
&lt;br /&gt;
==Lizenz einrichten==&lt;br /&gt;
&lt;br /&gt;
[[Datei:Sweep lizenz.png|400px|thumb|right|&#039;&#039;&#039;Eingabe der Sweep- und Tapering-Lizenz&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Der Testtongenerator und die Messfunktion stehen immer zur Verfügung. Für Sweeps und Auto-Sweeps ist dagegen eine Lizenz erforderlich, die Sie bei uns bestellen können (&#039;&#039;&#039;unbedingt&#039;&#039;&#039; Seriennummer Ihres HX3 angeben!). Die Eingabe der Lizennummer schaltet die Sweep-Funktionen frei.&lt;br /&gt;
&lt;br /&gt;
Klicken Sie nach dem &#039;&#039;&#039;Connect&#039;&#039;&#039; mit Ihrem Gerät im HX3-Manager-Startfenster auf &#039;&#039;&#039;Manager Licence&#039;&#039;&#039;. Im About-Dialog sollte nun Ihre Geräte-Seriennummer und als &amp;quot;Customer Name&amp;quot; ggf. Ihr Name erscheinen. Tragen Sie nun &amp;quot;Customer Name&amp;quot; und &amp;quot;Sweep Generator Licence Key&amp;quot; genau so ein wie in unserer Bestätigungs-Mail. Klicken Sie auf &#039;&#039;&#039;Activate&#039;&#039;&#039;. Hinter der Lizenznummer wird nun ein Häkchen angezeigt. SChließen Sie das Fenster mit &#039;&#039;&#039;OK&#039;&#039;&#039;.&lt;br /&gt;
&lt;br /&gt;
Die Lizenzdaten sind in der Datei &#039;&#039;HX3_userinfo.txt&#039;&#039; im Verzeichnis &#039;&#039;editor_files&#039;&#039; abgelegt. Bewahren Sie eine Kopie dieser Datei an einem sicheren Ort auf. Die Datei kann bei Verkauf weitergegeben oder beim Installieren eines Updates (aus ZIP-Datei) in das neue HX3-Manager-Verzeichnis (hier auch wieder in &#039;&#039;editor_files&#039;&#039;) kopiert werden, um die Lizenz für das Update zu übernehmen.&lt;br /&gt;
&lt;br /&gt;
==Sweep Analyzer==&lt;br /&gt;
&lt;br /&gt;
[[Datei:SweepAnalyzer.png|400px|thumb|right|&#039;&#039;&#039;Sweep Analyzer als eigenständiges Programm&#039;&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
Die Testgenerator- und Analyse-Funktionen stehen in Form der Applikation &#039;&#039;HX3_SweepAnalyzer.exe&#039;&#039; auch als eigenständiges Programm zur Verfügung. Das größere Fenster erlaubt eine übersichtlichere Darstellung, die Bedienung ist gleich wie oben. Zum Start darf der &#039;&#039;HX3 Manager&#039;&#039; nicht verbunden sein. Sie können dieses Programm getrennt vom HX3 Manager installieren und benutzen, es benötigt nur die &#039;&#039;user&#039;&#039;- und &#039;&#039;editor_files&#039;&#039;-Verzeichnisse.&lt;/div&gt;</summary>
		<author><name>Bovist</name></author>
	</entry>
</feed>